{"title":"停车场结构双三通预应力混凝土板耐火性能评估的合理方法","authors":"Puneet Kumar, V. Kodur","doi":"10.15554/pcij65.2-01","DOIUrl":null,"url":null,"abstract":"■ Case studies analyzed with the proposed rational approach indicate that fire-resistance predictions for double-tee slabs under current prescriptive approaches for evaluating fire resistance are overly conservative. Double-tee, prestressed concrete slabs offer numerous advantages over traditional slab systems in terms of higher load-carrying capacity, better use of space, cost-effectiveness, and optimized production. Consequently, the use of these slabs as a structural solution has gained popularity in recent decades. Double-tee slabs are often used in parking structures, where their longer spans reduce the total number of required columns, allowing better use of space.","PeriodicalId":54637,"journal":{"name":"PCI Journal","volume":"65 1","pages":""},"PeriodicalIF":0.9000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A Rational Approach for Fire-Resistance Evaluation of Double-Tee, Prestressed Concrete Slabs in Parking Structures\",\"authors\":\"Puneet Kumar, V. Kodur\",\"doi\":\"10.15554/pcij65.2-01\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"■ Case studies analyzed with the proposed rational approach indicate that fire-resistance predictions for double-tee slabs under current prescriptive approaches for evaluating fire resistance are overly conservative. Double-tee, prestressed concrete slabs offer numerous advantages over traditional slab systems in terms of higher load-carrying capacity, better use of space, cost-effectiveness, and optimized production. Consequently, the use of these slabs as a structural solution has gained popularity in recent decades. Double-tee slabs are often used in parking structures, where their longer spans reduce the total number of required columns, allowing better use of space.\",\"PeriodicalId\":54637,\"journal\":{\"name\":\"PCI Journal\",\"volume\":\"65 1\",\"pages\":\"\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PCI Journal\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.15554/pcij65.2-01\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PCI Journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.15554/pcij65.2-01","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
A Rational Approach for Fire-Resistance Evaluation of Double-Tee, Prestressed Concrete Slabs in Parking Structures
■ Case studies analyzed with the proposed rational approach indicate that fire-resistance predictions for double-tee slabs under current prescriptive approaches for evaluating fire resistance are overly conservative. Double-tee, prestressed concrete slabs offer numerous advantages over traditional slab systems in terms of higher load-carrying capacity, better use of space, cost-effectiveness, and optimized production. Consequently, the use of these slabs as a structural solution has gained popularity in recent decades. Double-tee slabs are often used in parking structures, where their longer spans reduce the total number of required columns, allowing better use of space.