碘包覆多晶铂电极伏安法测定制剂中扑热息痛

IF 0.7 Q4 CHEMISTRY, ANALYTICAL
Mohammad Amayreh, W. Hourani, M. Hourani
{"title":"碘包覆多晶铂电极伏安法测定制剂中扑热息痛","authors":"Mohammad Amayreh, W. Hourani, M. Hourani","doi":"10.17721/moca.2021.103-111","DOIUrl":null,"url":null,"abstract":"In this work the modified iodine-coated polycrystalline platinum electrode was used to develope a voltammetric sensor for paracetamol determination in pharmaceutical formulations. The optimized experimental parameters for the determination of paracetamol were using 0.5 M H2SO4 as a supporting electrolyte with a scan rate of 50 mV/s. The anodic peak related to paracetamol oxidation was centered at about +0.60 V. The extended calibration graph was constructed between 1 ppm and 500 ppm. The anodic current showed excellent linearity with R2 = 0.9985. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.046 and 0.139 ppm, respectively, which attests to the sensitivity of the method. The investigation for the effect of potential interferences from the content of tablet matrices indicated a specific selectivity toward paracetamol and the absence of any electrochemical response toward these components. The developed method was successfully applied to analysis paracetamol in three brands of pharmaceutical formulations and the obtained results were in good agreement with the labeled values, besides that, the statistical tests indicated no significant difference at p = 0.05 with a 95 % confidence level.","PeriodicalId":18626,"journal":{"name":"Methods and Objects of Chemical Analysis","volume":"1 1","pages":""},"PeriodicalIF":0.7000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Voltammetric Determination of Paracetamol in Pharmaceutical Formulations at Iodine-Coated Polycrystalline Platinum Electrode\",\"authors\":\"Mohammad Amayreh, W. Hourani, M. Hourani\",\"doi\":\"10.17721/moca.2021.103-111\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work the modified iodine-coated polycrystalline platinum electrode was used to develope a voltammetric sensor for paracetamol determination in pharmaceutical formulations. The optimized experimental parameters for the determination of paracetamol were using 0.5 M H2SO4 as a supporting electrolyte with a scan rate of 50 mV/s. The anodic peak related to paracetamol oxidation was centered at about +0.60 V. The extended calibration graph was constructed between 1 ppm and 500 ppm. The anodic current showed excellent linearity with R2 = 0.9985. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.046 and 0.139 ppm, respectively, which attests to the sensitivity of the method. The investigation for the effect of potential interferences from the content of tablet matrices indicated a specific selectivity toward paracetamol and the absence of any electrochemical response toward these components. The developed method was successfully applied to analysis paracetamol in three brands of pharmaceutical formulations and the obtained results were in good agreement with the labeled values, besides that, the statistical tests indicated no significant difference at p = 0.05 with a 95 % confidence level.\",\"PeriodicalId\":18626,\"journal\":{\"name\":\"Methods and Objects of Chemical Analysis\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Methods and Objects of Chemical Analysis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17721/moca.2021.103-111\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Methods and Objects of Chemical Analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17721/moca.2021.103-111","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 3

摘要

本文采用碘包覆改性多晶铂电极,研制了一种测定制剂中扑热息痛的伏安传感器。优化的测定对乙酰氨基酚的实验参数为:以0.5 M H2SO4为载体电解质,扫描速率为50 mV/s。与扑热息痛氧化有关的阳极峰集中在+0.60 V左右。在1ppm ~ 500ppm范围内构建扩展校准图。阳极电流线性良好,R2 = 0.9985。检测限和定量限分别为0.046和0.139 ppm,证明了该方法的灵敏度。研究表明,对扑热息痛有一定的选择性,对这些成分没有电化学反应。将所建立的方法成功地应用于三种品牌制剂中扑热息痛的分析,所得结果与标签值吻合较好,且经统计学检验,p = 0.05,置信水平为95%,差异不显著。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Voltammetric Determination of Paracetamol in Pharmaceutical Formulations at Iodine-Coated Polycrystalline Platinum Electrode
In this work the modified iodine-coated polycrystalline platinum electrode was used to develope a voltammetric sensor for paracetamol determination in pharmaceutical formulations. The optimized experimental parameters for the determination of paracetamol were using 0.5 M H2SO4 as a supporting electrolyte with a scan rate of 50 mV/s. The anodic peak related to paracetamol oxidation was centered at about +0.60 V. The extended calibration graph was constructed between 1 ppm and 500 ppm. The anodic current showed excellent linearity with R2 = 0.9985. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.046 and 0.139 ppm, respectively, which attests to the sensitivity of the method. The investigation for the effect of potential interferences from the content of tablet matrices indicated a specific selectivity toward paracetamol and the absence of any electrochemical response toward these components. The developed method was successfully applied to analysis paracetamol in three brands of pharmaceutical formulations and the obtained results were in good agreement with the labeled values, besides that, the statistical tests indicated no significant difference at p = 0.05 with a 95 % confidence level.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.00
自引率
14.30%
发文量
12
期刊介绍: The journal "Methods and objects of chemical analysis" is peer-review journal and publishes original articles of theoretical and experimental analysis on topical issues and bio-analytical chemistry, chemical and pharmaceutical analysis, as well as chemical metrology. Submitted works shall cover the results of completed studies and shall make scientific contributions to the relevant area of expertise. The journal publishes review articles, research articles and articles related to latest developments of analytical instrumentations.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信