双标准加成法对不同色谱定量的比较表征

Q4 Chemistry
I. Zenkevich, Darina Barkhatova, Maria Belysheva, N. A. Kaminskii, Elizabet M. Karchuganova, Anastasia V. Klaving, Alexander A. Kovalenko, Vasilisa Krivovicheva, Artem A. Kuz’min, M. V. Mel’nik, Polina Paramonova, R. Popov, Vassylii V. Potapenkov, A. A. Rashevskii, Alexandra A. Sysoeva, Irina I. Fedorova, A. A. Firsov
{"title":"双标准加成法对不同色谱定量的比较表征","authors":"I. Zenkevich, Darina Barkhatova, Maria Belysheva, N. A. Kaminskii, Elizabet M. Karchuganova, Anastasia V. Klaving, Alexander A. Kovalenko, Vasilisa Krivovicheva, Artem A. Kuz’min, M. V. Mel’nik, Polina Paramonova, R. Popov, Vassylii V. Potapenkov, A. A. Rashevskii, Alexandra A. Sysoeva, Irina I. Fedorova, A. A. Firsov","doi":"10.15826/analitika.2021.25.2.010","DOIUrl":null,"url":null,"abstract":"Different algorithms for processing the quantitative gas chromato­gra­­phic ana­lysis data using the double standard addition method are compared for their accuracy. Three principal approaches are possible for such processing: I – simple comparison of values determined by sing­le and double standard additions, II – approximation of «peak area of ana­lyte» (S) – «mass of standard addition» (madd) depen­den­ce by the least squa­res method [linear reg­res­sion, m(S)], and III – independent quantification of analyte with both standard additi­ons follo­wed by the linear extrapolation of two sub-results on the so-cal­led «zero standard addi­tion», mx(madd ® 0). It is concluded that the quantitation results obtained using the various modes of the method are comparable in accuracy, but somewhat underestimated relative to the specified amounts of analytes. The principal reason of such systematic errors is the eva­po­ration of the solvent during the successive injecting of the same samples into the gas chroma­to­graph. Due to this reason the peak are­as, measured after the standard addition, appear to be slight­­ly increased and this leads to the systematic underestimation of the results. The second (less impor­tant) factor is the small increa­se of the samp­le volumes due to the addition of the compo­nents to be determined. It is confirmed that the systematic errors of different modes of standard addition are not exceeding the values of their random uncertainties. The op­ti­mal results (considering their signs of deviations) are provided using the double standard addition method with extrapolation of sub-results on «zero standard addition». In order to exclude the possible influence of «human factor» (increasing the re­sults precision during the series of analyses of similar samples due to the rising experience of analytical chemists) all parallel measurements have been per­for­med by bachelor students of the Chemistry Ins­titute of the St. Petersburg State University in the course of their laboratory practical works in chromatography. Such organization of experiments increases their credibility as it excluded the dependence of the results on the qualification of chemists.","PeriodicalId":37743,"journal":{"name":"Analitika i Kontrol","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative characterization of different kinds of chromatographic quantification using the double standard addition method\",\"authors\":\"I. Zenkevich, Darina Barkhatova, Maria Belysheva, N. A. Kaminskii, Elizabet M. Karchuganova, Anastasia V. Klaving, Alexander A. Kovalenko, Vasilisa Krivovicheva, Artem A. Kuz’min, M. V. Mel’nik, Polina Paramonova, R. Popov, Vassylii V. Potapenkov, A. A. Rashevskii, Alexandra A. Sysoeva, Irina I. Fedorova, A. A. Firsov\",\"doi\":\"10.15826/analitika.2021.25.2.010\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Different algorithms for processing the quantitative gas chromato­gra­­phic ana­lysis data using the double standard addition method are compared for their accuracy. Three principal approaches are possible for such processing: I – simple comparison of values determined by sing­le and double standard additions, II – approximation of «peak area of ana­lyte» (S) – «mass of standard addition» (madd) depen­den­ce by the least squa­res method [linear reg­res­sion, m(S)], and III – independent quantification of analyte with both standard additi­ons follo­wed by the linear extrapolation of two sub-results on the so-cal­led «zero standard addi­tion», mx(madd ® 0). It is concluded that the quantitation results obtained using the various modes of the method are comparable in accuracy, but somewhat underestimated relative to the specified amounts of analytes. The principal reason of such systematic errors is the eva­po­ration of the solvent during the successive injecting of the same samples into the gas chroma­to­graph. Due to this reason the peak are­as, measured after the standard addition, appear to be slight­­ly increased and this leads to the systematic underestimation of the results. The second (less impor­tant) factor is the small increa­se of the samp­le volumes due to the addition of the compo­nents to be determined. It is confirmed that the systematic errors of different modes of standard addition are not exceeding the values of their random uncertainties. The op­ti­mal results (considering their signs of deviations) are provided using the double standard addition method with extrapolation of sub-results on «zero standard addition». In order to exclude the possible influence of «human factor» (increasing the re­sults precision during the series of analyses of similar samples due to the rising experience of analytical chemists) all parallel measurements have been per­for­med by bachelor students of the Chemistry Ins­titute of the St. Petersburg State University in the course of their laboratory practical works in chromatography. Such organization of experiments increases their credibility as it excluded the dependence of the results on the qualification of chemists.\",\"PeriodicalId\":37743,\"journal\":{\"name\":\"Analitika i Kontrol\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analitika i Kontrol\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15826/analitika.2021.25.2.010\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Chemistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analitika i Kontrol","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15826/analitika.2021.25.2.010","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Chemistry","Score":null,"Total":0}
引用次数: 0

摘要

比较了双标准加成法处理气相色谱定量分析数据的不同算法的准确性。这种处理有三种主要方法:I -通过单标准和双标准添加确定的值的简单比较,II -通过最小二乘法近似“分析液峰面积”(S) -“标准添加质量”(madd)依赖[线性回归,m(S)],以及III -使用两种标准添加对分析物进行独立量化,然后在所谓的“零标准添加”上对两个子结果进行线性外推。结论是,使用该方法的各种模式获得的定量结果在准确性上是相当的,但相对于规定的分析物量有些低估。这种系统误差的主要原因是在连续向气相色谱中注入相同样品时溶剂的挥发。由于这个原因,在标准添加后测量的峰值are-as似乎略有增加,这导致了对结果的系统性低估。第二个(不太重要的)因素是样品体积的小幅增加,这是由于添加了待测定的成分。结果表明,不同标准相加方式的系统误差均不超过其随机不确定度。使用双标准加法法和对“零标准加法”子结果的外推,提供了最优结果(考虑其偏差的迹象)。为了排除可能的“人为因素”的影响(由于分析化学家的经验不断增加,在对类似样品进行一系列分析时提高结果的精度),所有平行测量都由圣彼得堡国立大学化学研究所的本科生在他们的色谱实验室实际工作过程中完成。这样的实验组织增加了它们的可信度,因为它排除了结果对化学家资格的依赖。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparative characterization of different kinds of chromatographic quantification using the double standard addition method
Different algorithms for processing the quantitative gas chromato­gra­­phic ana­lysis data using the double standard addition method are compared for their accuracy. Three principal approaches are possible for such processing: I – simple comparison of values determined by sing­le and double standard additions, II – approximation of «peak area of ana­lyte» (S) – «mass of standard addition» (madd) depen­den­ce by the least squa­res method [linear reg­res­sion, m(S)], and III – independent quantification of analyte with both standard additi­ons follo­wed by the linear extrapolation of two sub-results on the so-cal­led «zero standard addi­tion», mx(madd ® 0). It is concluded that the quantitation results obtained using the various modes of the method are comparable in accuracy, but somewhat underestimated relative to the specified amounts of analytes. The principal reason of such systematic errors is the eva­po­ration of the solvent during the successive injecting of the same samples into the gas chroma­to­graph. Due to this reason the peak are­as, measured after the standard addition, appear to be slight­­ly increased and this leads to the systematic underestimation of the results. The second (less impor­tant) factor is the small increa­se of the samp­le volumes due to the addition of the compo­nents to be determined. It is confirmed that the systematic errors of different modes of standard addition are not exceeding the values of their random uncertainties. The op­ti­mal results (considering their signs of deviations) are provided using the double standard addition method with extrapolation of sub-results on «zero standard addition». In order to exclude the possible influence of «human factor» (increasing the re­sults precision during the series of analyses of similar samples due to the rising experience of analytical chemists) all parallel measurements have been per­for­med by bachelor students of the Chemistry Ins­titute of the St. Petersburg State University in the course of their laboratory practical works in chromatography. Such organization of experiments increases their credibility as it excluded the dependence of the results on the qualification of chemists.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analitika i Kontrol
Analitika i Kontrol Chemistry-Analytical Chemistry
CiteScore
0.90
自引率
0.00%
发文量
15
期刊介绍: Analitika i Kontrol is a scientific journal covering theoretical and applied aspects of analytical chemistry and analytical control, published since autumn 1997. Founder and publisher of the journal is the Ural Federal University named after the first President of Russia Boris Yeltsin (UrFU, Ekaterinburg).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信