固相分光光度法测定酸奶中Е102、Е110、Е124、Е131合成染料

Q4 Chemistry
A. A. Dudkina, N. V. Saranchina, T. Volgina, N. Gavrilenko, M. A. Gavrilenko
{"title":"固相分光光度法测定酸奶中Е102、Е110、Е124、Е131合成染料","authors":"A. A. Dudkina, N. V. Saranchina, T. Volgina, N. Gavrilenko, M. A. Gavrilenko","doi":"10.15826/analitika.2020.24.1.002","DOIUrl":null,"url":null,"abstract":"solid-phase extraction from yoghurts and biokefirs in a transparent polymethylmethacrylate matrix as a solid extractant was studied. The analytical signal was formed due to the accumulation of the dye in the volume of the polymer matrix without violating the transparency, and this corresponded to the wavelength of the maximum absorption of the corresponding dye. The sorption mechanism was based on the protonization of the carbonyl groups of PMM in the acidic media, and, as a result, the optode surface became positively charged. Therefore, the sorption of the R ± form of the E131 dye and the azo dye anions occurred by the positively charged PMM surface. The effectiveness of the proposed approach was shown for the identification and determination of the 2 food-grade synthetic dyes content using the visual and spectrophotometric methods. The optimal conditions for the analysis corresponded to pH <3, the duration of dye extraction into the polymer matrix was 20 min, the range of the detected concentrations was 0.2–40.0 mg / kg with the detection limit of 0.05 mg/kg, and an excess of sweeteners and preservatives did not significantly affect the results of the analysis. The results of the determination of the listed dyes were demonstrated in the current work for the case of individual and group presence of dyes in biokefirs and yogurts. The proposed technique is simple in execution and could be carried out using the standard spectrophotometric equipment. The advantage of the developed method for the determination of artificial dyes in comparison with the method of spectrophotometric determination with liquid extraction is a significant increase in the sensitivity of determination due to the accumulation of analyte, the exclusion of turbidity of an aliquot and the absence of dye loss due to its transition into the supernatant, and then into the solid phase of the matrix.","PeriodicalId":37743,"journal":{"name":"Analitika i Kontrol","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determination of Е102, Е110, Е124, Е131 synthetic dyes in yogurt using the solid-phase spectrophotometry\",\"authors\":\"A. A. Dudkina, N. V. Saranchina, T. Volgina, N. Gavrilenko, M. A. Gavrilenko\",\"doi\":\"10.15826/analitika.2020.24.1.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"solid-phase extraction from yoghurts and biokefirs in a transparent polymethylmethacrylate matrix as a solid extractant was studied. The analytical signal was formed due to the accumulation of the dye in the volume of the polymer matrix without violating the transparency, and this corresponded to the wavelength of the maximum absorption of the corresponding dye. The sorption mechanism was based on the protonization of the carbonyl groups of PMM in the acidic media, and, as a result, the optode surface became positively charged. Therefore, the sorption of the R ± form of the E131 dye and the azo dye anions occurred by the positively charged PMM surface. The effectiveness of the proposed approach was shown for the identification and determination of the 2 food-grade synthetic dyes content using the visual and spectrophotometric methods. The optimal conditions for the analysis corresponded to pH <3, the duration of dye extraction into the polymer matrix was 20 min, the range of the detected concentrations was 0.2–40.0 mg / kg with the detection limit of 0.05 mg/kg, and an excess of sweeteners and preservatives did not significantly affect the results of the analysis. The results of the determination of the listed dyes were demonstrated in the current work for the case of individual and group presence of dyes in biokefirs and yogurts. The proposed technique is simple in execution and could be carried out using the standard spectrophotometric equipment. The advantage of the developed method for the determination of artificial dyes in comparison with the method of spectrophotometric determination with liquid extraction is a significant increase in the sensitivity of determination due to the accumulation of analyte, the exclusion of turbidity of an aliquot and the absence of dye loss due to its transition into the supernatant, and then into the solid phase of the matrix.\",\"PeriodicalId\":37743,\"journal\":{\"name\":\"Analitika i Kontrol\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analitika i Kontrol\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15826/analitika.2020.24.1.002\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Chemistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analitika i Kontrol","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15826/analitika.2020.24.1.002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Chemistry","Score":null,"Total":0}
引用次数: 0

摘要

以透明聚甲基丙烯酸甲酯为固体萃取剂,研究了酸奶和生酮的固相萃取。分析信号是由于染料在聚合物基体的体积中积累而形成的,而不违反透明度,这与相应染料的最大吸收波长相对应。吸附机理是基于PMM的羰基在酸性介质中的质子化,因此,光电器件表面带正电。因此,带正电的PMM表面吸附了R±形式的E131染料和偶氮染料阴离子。该方法可用于两种食品级合成染料的视觉和分光光度测定。分析的最佳条件为pH <3,染料在聚合物基质中的提取时间为20 min,检测浓度范围为0.2 ~ 40.0 mg/kg,检出限为0.05 mg/kg,甜味剂和防腐剂的过量使用对分析结果没有显著影响。所列染料的测定结果在目前的工作中得到了证明,用于生物酵母和酸奶中单个和组存在染料的情况。该方法操作简单,可在标准分光光度仪上进行测定。与液体萃取分光光度法测定人工染料的方法相比,该方法的优点是由于分析物的积累,排除了混浊,并且没有因其过渡到上清,然后进入基质固相而造成的染料损失,从而显著提高了测定的灵敏度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Determination of Е102, Е110, Е124, Е131 synthetic dyes in yogurt using the solid-phase spectrophotometry
solid-phase extraction from yoghurts and biokefirs in a transparent polymethylmethacrylate matrix as a solid extractant was studied. The analytical signal was formed due to the accumulation of the dye in the volume of the polymer matrix without violating the transparency, and this corresponded to the wavelength of the maximum absorption of the corresponding dye. The sorption mechanism was based on the protonization of the carbonyl groups of PMM in the acidic media, and, as a result, the optode surface became positively charged. Therefore, the sorption of the R ± form of the E131 dye and the azo dye anions occurred by the positively charged PMM surface. The effectiveness of the proposed approach was shown for the identification and determination of the 2 food-grade synthetic dyes content using the visual and spectrophotometric methods. The optimal conditions for the analysis corresponded to pH <3, the duration of dye extraction into the polymer matrix was 20 min, the range of the detected concentrations was 0.2–40.0 mg / kg with the detection limit of 0.05 mg/kg, and an excess of sweeteners and preservatives did not significantly affect the results of the analysis. The results of the determination of the listed dyes were demonstrated in the current work for the case of individual and group presence of dyes in biokefirs and yogurts. The proposed technique is simple in execution and could be carried out using the standard spectrophotometric equipment. The advantage of the developed method for the determination of artificial dyes in comparison with the method of spectrophotometric determination with liquid extraction is a significant increase in the sensitivity of determination due to the accumulation of analyte, the exclusion of turbidity of an aliquot and the absence of dye loss due to its transition into the supernatant, and then into the solid phase of the matrix.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analitika i Kontrol
Analitika i Kontrol Chemistry-Analytical Chemistry
CiteScore
0.90
自引率
0.00%
发文量
15
期刊介绍: Analitika i Kontrol is a scientific journal covering theoretical and applied aspects of analytical chemistry and analytical control, published since autumn 1997. Founder and publisher of the journal is the Ural Federal University named after the first President of Russia Boris Yeltsin (UrFU, Ekaterinburg).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信