Davor Skejić, Ivan Rogic, Ana Šitum, D. Lange, L. Boström
{"title":"钢梁耐火性能计算方法评定","authors":"Davor Skejić, Ivan Rogic, Ana Šitum, D. Lange, L. Boström","doi":"10.14256/JCE.2211.2017","DOIUrl":null,"url":null,"abstract":"Experience shows that the assessment of fire resistance of steel elements based on European standards is conservative, while advanced methods are complex and time consuming. The analysis of existing methods for the tested steel beam exposed to bending and standard ISO fire was conducted in the scope of the international Round Robin study. The comparison of results shows that advanced methods provide nonuniform assessments. Nevertheless, advanced methods are necessary for improving standard methods that overestimate fire resistance of this \"trivial\" problem.","PeriodicalId":50415,"journal":{"name":"Gradevinar","volume":"70 1","pages":"159-169"},"PeriodicalIF":1.0000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of methods for calculating fire resistance of a steel beam\",\"authors\":\"Davor Skejić, Ivan Rogic, Ana Šitum, D. Lange, L. Boström\",\"doi\":\"10.14256/JCE.2211.2017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Experience shows that the assessment of fire resistance of steel elements based on European standards is conservative, while advanced methods are complex and time consuming. The analysis of existing methods for the tested steel beam exposed to bending and standard ISO fire was conducted in the scope of the international Round Robin study. The comparison of results shows that advanced methods provide nonuniform assessments. Nevertheless, advanced methods are necessary for improving standard methods that overestimate fire resistance of this \\\"trivial\\\" problem.\",\"PeriodicalId\":50415,\"journal\":{\"name\":\"Gradevinar\",\"volume\":\"70 1\",\"pages\":\"159-169\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2018-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Gradevinar\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.14256/JCE.2211.2017\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, CIVIL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gradevinar","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.14256/JCE.2211.2017","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
Assessment of methods for calculating fire resistance of a steel beam
Experience shows that the assessment of fire resistance of steel elements based on European standards is conservative, while advanced methods are complex and time consuming. The analysis of existing methods for the tested steel beam exposed to bending and standard ISO fire was conducted in the scope of the international Round Robin study. The comparison of results shows that advanced methods provide nonuniform assessments. Nevertheless, advanced methods are necessary for improving standard methods that overestimate fire resistance of this "trivial" problem.