{"title":"自动连接变压器与40°相移谐波消除","authors":"Arafet Ben Ammar, F. B. Ammar","doi":"10.1504/IJSISE.2016.078260","DOIUrl":null,"url":null,"abstract":"The conventional six-pulse and 12-pulse generate harmonics pollution in the network. In order to reduce the harmonics propagation has proposed the use of other structures that offer a greater flexibility to transit control of energy and a significant harmonics reduction. In this paper, the authors present the design, analysis and experimental set-up of a delta-connected autotransformer-based 18-pulse ac-dc converter with 40° phase shifting to decrease the harmonics pollution in the network side. The simulation results show that autotransformer configuration 18-pulse capable to suppress harmonics of the order less than 18th.n±1. This design gives a better THD current compared with the two configurations, six-pulse and 12-pulse. Moreover, a prototype of the proposed autotransformer-based 18-pulse ac-dc converter is developed and test results are presented to validate the developed design procedure and simulation models of this ac-dc converter.","PeriodicalId":56359,"journal":{"name":"International Journal of Signal and Imaging Systems Engineering","volume":"9 1","pages":"233"},"PeriodicalIF":0.6000,"publicationDate":"2016-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1504/IJSISE.2016.078260","citationCount":"0","resultStr":"{\"title\":\"Auto-connected transformer with 40° phase shifting for harmonic elimination\",\"authors\":\"Arafet Ben Ammar, F. B. Ammar\",\"doi\":\"10.1504/IJSISE.2016.078260\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The conventional six-pulse and 12-pulse generate harmonics pollution in the network. In order to reduce the harmonics propagation has proposed the use of other structures that offer a greater flexibility to transit control of energy and a significant harmonics reduction. In this paper, the authors present the design, analysis and experimental set-up of a delta-connected autotransformer-based 18-pulse ac-dc converter with 40° phase shifting to decrease the harmonics pollution in the network side. The simulation results show that autotransformer configuration 18-pulse capable to suppress harmonics of the order less than 18th.n±1. This design gives a better THD current compared with the two configurations, six-pulse and 12-pulse. Moreover, a prototype of the proposed autotransformer-based 18-pulse ac-dc converter is developed and test results are presented to validate the developed design procedure and simulation models of this ac-dc converter.\",\"PeriodicalId\":56359,\"journal\":{\"name\":\"International Journal of Signal and Imaging Systems Engineering\",\"volume\":\"9 1\",\"pages\":\"233\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2016-08-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1504/IJSISE.2016.078260\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Signal and Imaging Systems Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1504/IJSISE.2016.078260\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Signal and Imaging Systems Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1504/IJSISE.2016.078260","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
Auto-connected transformer with 40° phase shifting for harmonic elimination
The conventional six-pulse and 12-pulse generate harmonics pollution in the network. In order to reduce the harmonics propagation has proposed the use of other structures that offer a greater flexibility to transit control of energy and a significant harmonics reduction. In this paper, the authors present the design, analysis and experimental set-up of a delta-connected autotransformer-based 18-pulse ac-dc converter with 40° phase shifting to decrease the harmonics pollution in the network side. The simulation results show that autotransformer configuration 18-pulse capable to suppress harmonics of the order less than 18th.n±1. This design gives a better THD current compared with the two configurations, six-pulse and 12-pulse. Moreover, a prototype of the proposed autotransformer-based 18-pulse ac-dc converter is developed and test results are presented to validate the developed design procedure and simulation models of this ac-dc converter.