{"title":"导体上单个正电晕源可听噪声时域波形的分析与拟合","authors":"Xuebao Li, X. Cui, T. Lu, Di Zhang","doi":"10.13335/J.1000-3673.PST.2014.06.019","DOIUrl":null,"url":null,"abstract":"The time-domain waveform of audible noise caused by the discharge of single positive corona source is obtained by the time-domain test platform set up in the laboratory. According to the pulse characteristic of time-domain waveform of audible noise it is proposed to utilize segmented double-exponential function to fit single time-domain pulse waveform of single audible noise to obtain empirical waveform, and through the comparative research on fitting results and measured results in time-domain and frequency-domain the reasonableness of the proposed method of the fitted waveform is validated. Finally, based on the measured results of long-term audible noise in time-domain the statistical characteristics of fitting parameters of the segmented double-exponential function under different voltages and that of waveform parameters of audible noise. Experimental results show that due to the randomness of corona discharge, the pulse waveform parameters and waveform fitting parameters evidently fluctuate under the same voltage; the time interval of audible noise pulse decreased with the increase of the applied voltage, however the pulse width and its apparent duration slightly varies under different voltages.","PeriodicalId":20420,"journal":{"name":"电网技术","volume":"38 1","pages":"1542-1548"},"PeriodicalIF":0.0000,"publicationDate":"2014-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Analysis and Fitting of the Time-domain Waveform of the Audible Noise Caused by Single Positive Corona Source on the Conductor\",\"authors\":\"Xuebao Li, X. Cui, T. Lu, Di Zhang\",\"doi\":\"10.13335/J.1000-3673.PST.2014.06.019\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The time-domain waveform of audible noise caused by the discharge of single positive corona source is obtained by the time-domain test platform set up in the laboratory. According to the pulse characteristic of time-domain waveform of audible noise it is proposed to utilize segmented double-exponential function to fit single time-domain pulse waveform of single audible noise to obtain empirical waveform, and through the comparative research on fitting results and measured results in time-domain and frequency-domain the reasonableness of the proposed method of the fitted waveform is validated. Finally, based on the measured results of long-term audible noise in time-domain the statistical characteristics of fitting parameters of the segmented double-exponential function under different voltages and that of waveform parameters of audible noise. Experimental results show that due to the randomness of corona discharge, the pulse waveform parameters and waveform fitting parameters evidently fluctuate under the same voltage; the time interval of audible noise pulse decreased with the increase of the applied voltage, however the pulse width and its apparent duration slightly varies under different voltages.\",\"PeriodicalId\":20420,\"journal\":{\"name\":\"电网技术\",\"volume\":\"38 1\",\"pages\":\"1542-1548\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"电网技术\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://doi.org/10.13335/J.1000-3673.PST.2014.06.019\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"电网技术","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.13335/J.1000-3673.PST.2014.06.019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Engineering","Score":null,"Total":0}
Analysis and Fitting of the Time-domain Waveform of the Audible Noise Caused by Single Positive Corona Source on the Conductor
The time-domain waveform of audible noise caused by the discharge of single positive corona source is obtained by the time-domain test platform set up in the laboratory. According to the pulse characteristic of time-domain waveform of audible noise it is proposed to utilize segmented double-exponential function to fit single time-domain pulse waveform of single audible noise to obtain empirical waveform, and through the comparative research on fitting results and measured results in time-domain and frequency-domain the reasonableness of the proposed method of the fitted waveform is validated. Finally, based on the measured results of long-term audible noise in time-domain the statistical characteristics of fitting parameters of the segmented double-exponential function under different voltages and that of waveform parameters of audible noise. Experimental results show that due to the randomness of corona discharge, the pulse waveform parameters and waveform fitting parameters evidently fluctuate under the same voltage; the time interval of audible noise pulse decreased with the increase of the applied voltage, however the pulse width and its apparent duration slightly varies under different voltages.
期刊介绍:
"Power System Technology" (monthly) was founded in 1957. It is a comprehensive academic journal in the field of energy and power, supervised and sponsored by the State Grid Corporation of China. It is published by the Power System Technology Magazine Co., Ltd. of the China Electric Power Research Institute. It is publicly distributed at home and abroad and is included in 12 famous domestic and foreign literature databases such as the Engineering Index (EI) and the National Chinese Core Journals.
The purpose of "Power System Technology" is to serve the national innovation-driven development strategy, promote scientific and technological progress in my country's energy and power fields, and promote the application of new technologies and new products. "Power System Technology" has adhered to the publishing characteristics of combining "theoretical innovation with applied practice" for many years, and the scope of manuscript selection covers the fields of power generation, transmission, distribution, and electricity consumption.