单目摄像机标定方法研究

阳阳 侯
{"title":"单目摄像机标定方法研究","authors":"阳阳 侯","doi":"10.12677/jisp.2023.121004","DOIUrl":null,"url":null,"abstract":"In order to reduce the error and improve the calibration accuracy, the calibration parameters obtained by the solution are nonlinear iteratively based on the plane checkerboard calibration method to minimize the reprojection error and find the global optimal solution. After analyzing the theoretical imaging model of the camera and studying the nonlinear camera imaging model after introducing distortion parameters, the camera transformation matrix and the parameters in the camera are solved, and finally the calibration results are optimized. The experimental results show that the mean calibration error of this method is 0.1402 and the standard deviation is 0.0207, which has higher accuracy and better stability than the traditional calibration method and has certain engineering practical significance.","PeriodicalId":69487,"journal":{"name":"图像与信号处理","volume":"7 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Research on the Method of Monocular Camera Calibration\",\"authors\":\"阳阳 侯\",\"doi\":\"10.12677/jisp.2023.121004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to reduce the error and improve the calibration accuracy, the calibration parameters obtained by the solution are nonlinear iteratively based on the plane checkerboard calibration method to minimize the reprojection error and find the global optimal solution. After analyzing the theoretical imaging model of the camera and studying the nonlinear camera imaging model after introducing distortion parameters, the camera transformation matrix and the parameters in the camera are solved, and finally the calibration results are optimized. The experimental results show that the mean calibration error of this method is 0.1402 and the standard deviation is 0.0207, which has higher accuracy and better stability than the traditional calibration method and has certain engineering practical significance.\",\"PeriodicalId\":69487,\"journal\":{\"name\":\"图像与信号处理\",\"volume\":\"7 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"图像与信号处理\",\"FirstCategoryId\":\"1093\",\"ListUrlMain\":\"https://doi.org/10.12677/jisp.2023.121004\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"图像与信号处理","FirstCategoryId":"1093","ListUrlMain":"https://doi.org/10.12677/jisp.2023.121004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Research on the Method of Monocular Camera Calibration
In order to reduce the error and improve the calibration accuracy, the calibration parameters obtained by the solution are nonlinear iteratively based on the plane checkerboard calibration method to minimize the reprojection error and find the global optimal solution. After analyzing the theoretical imaging model of the camera and studying the nonlinear camera imaging model after introducing distortion parameters, the camera transformation matrix and the parameters in the camera are solved, and finally the calibration results are optimized. The experimental results show that the mean calibration error of this method is 0.1402 and the standard deviation is 0.0207, which has higher accuracy and better stability than the traditional calibration method and has certain engineering practical significance.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
154
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信