{"title":"液压油中溶解空气对气蚀的影响","authors":"Sven Osterland, L. Müller, J. Weber","doi":"10.13052/ijfp1439-9776.2234","DOIUrl":null,"url":null,"abstract":"This article gives experimentally evidence that cavitation erosion in hydraulic components like valves and pumps is caused by vapour cavitation not gas or pseudo cavitation. In fact, the free air content which is released by vapour and gas cavitation reduces the erosion significantly. In order to clearly separate the different cavitation types, a test rig with a specially designed reservoir with integrated degassing capability is presented. As flow geometry a valve model with realistic dimensions and under realistic operating conditions was used, which ensures very high transferability of the results to the reality of hydraulic components in practical applications and typical operating conditions. A total of 4 five-hour long tests are performed and analysed. The quantification of the cavitation erosion is determined by the mass loss of the copper samples. The experimental results show a 4.4–5.1 times higher mass loss in tests with air-free oil compared to tests with air-saturated or oversaturated hydraulic oil. The experimental fact that air-free hydraulic oil causes significantly more cavitation erosion than normal (saturated) hydraulic oil, and its implications are discussed. The conclusion can be drawn, that further developments of hydraulic components and systems towards the use of air-free oil or increasing power densities will be disproportionately challenged by cavitation erosion.","PeriodicalId":13977,"journal":{"name":"International Journal of Fluid Power","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Influence of Air Dissolved in Hydraulic Oil on Cavitation Erosion\",\"authors\":\"Sven Osterland, L. Müller, J. Weber\",\"doi\":\"10.13052/ijfp1439-9776.2234\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This article gives experimentally evidence that cavitation erosion in hydraulic components like valves and pumps is caused by vapour cavitation not gas or pseudo cavitation. In fact, the free air content which is released by vapour and gas cavitation reduces the erosion significantly. In order to clearly separate the different cavitation types, a test rig with a specially designed reservoir with integrated degassing capability is presented. As flow geometry a valve model with realistic dimensions and under realistic operating conditions was used, which ensures very high transferability of the results to the reality of hydraulic components in practical applications and typical operating conditions. A total of 4 five-hour long tests are performed and analysed. The quantification of the cavitation erosion is determined by the mass loss of the copper samples. The experimental results show a 4.4–5.1 times higher mass loss in tests with air-free oil compared to tests with air-saturated or oversaturated hydraulic oil. The experimental fact that air-free hydraulic oil causes significantly more cavitation erosion than normal (saturated) hydraulic oil, and its implications are discussed. The conclusion can be drawn, that further developments of hydraulic components and systems towards the use of air-free oil or increasing power densities will be disproportionately challenged by cavitation erosion.\",\"PeriodicalId\":13977,\"journal\":{\"name\":\"International Journal of Fluid Power\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Fluid Power\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.13052/ijfp1439-9776.2234\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Fluid Power","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.13052/ijfp1439-9776.2234","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 4

摘要

本文通过实验证明,阀门和泵等液压元件的空化侵蚀是由蒸汽空化引起的,而不是由气体或伪空化引起的。事实上,水蒸气和气体空化所释放的自由空气含量大大减少了侵蚀。为了明确区分不同类型的空化,设计了一种具有综合脱气能力的特殊储层试验台。在流动几何方面,采用了具有实际尺寸和实际工况的阀模型,保证了计算结果与液压元件实际应用和典型工况的可移植性。总共进行了4次长达5小时的测试并进行了分析。空化腐蚀的定量是由铜样品的质量损失决定的。实验结果表明,与使用饱和或过饱和液压油相比,使用无空气液压油的质量损失高4.4-5.1倍。无空气液压油比正常(饱和)液压油引起更大的空化侵蚀的实验事实,并讨论了其影响。可以得出的结论是,液压元件和系统向使用无空气油或增加功率密度的进一步发展将受到空化侵蚀的不成比例的挑战。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Influence of Air Dissolved in Hydraulic Oil on Cavitation Erosion
This article gives experimentally evidence that cavitation erosion in hydraulic components like valves and pumps is caused by vapour cavitation not gas or pseudo cavitation. In fact, the free air content which is released by vapour and gas cavitation reduces the erosion significantly. In order to clearly separate the different cavitation types, a test rig with a specially designed reservoir with integrated degassing capability is presented. As flow geometry a valve model with realistic dimensions and under realistic operating conditions was used, which ensures very high transferability of the results to the reality of hydraulic components in practical applications and typical operating conditions. A total of 4 five-hour long tests are performed and analysed. The quantification of the cavitation erosion is determined by the mass loss of the copper samples. The experimental results show a 4.4–5.1 times higher mass loss in tests with air-free oil compared to tests with air-saturated or oversaturated hydraulic oil. The experimental fact that air-free hydraulic oil causes significantly more cavitation erosion than normal (saturated) hydraulic oil, and its implications are discussed. The conclusion can be drawn, that further developments of hydraulic components and systems towards the use of air-free oil or increasing power densities will be disproportionately challenged by cavitation erosion.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Fluid Power
International Journal of Fluid Power ENGINEERING, MECHANICAL-
CiteScore
1.60
自引率
0.00%
发文量
16
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信