便携式微型晶体管射频耦合心脏起搏器

Hickman Dm, L. Geddes, H. Hoff, M. Hinds, A. G. Moore, C. K. Francis, T. Engen
{"title":"便携式微型晶体管射频耦合心脏起搏器","authors":"Hickman Dm, L. Geddes, H. Hoff, M. Hinds, A. G. Moore, C. K. Francis, T. Engen","doi":"10.1109/TBMEL.1961.4322926","DOIUrl":null,"url":null,"abstract":"A miniature, transistorized radio-frequency-coupled cardiac pacemaker was developed to eliminate wires penetrating the skin when electrodes are placed on the heart to drive it. The design also eliminates the need for totally implanting a pacemaker with its batteries. The stimulating impulse is transmitted via amplitude modulation to a tuned circuit and detector assembly implanted below the skin. The output of the detector is connected to electrodes directly on the heart, making external control of the heart rate possible. In operation, the pacemaker transmitter is placed on the surface of the body above the receiver implant. The size of the unit is 4×13/4 ×13/2 inches. It weighs three ounces.","PeriodicalId":86470,"journal":{"name":"IRE transactions on bio-medical electronics","volume":"8 1","pages":"258-262"},"PeriodicalIF":0.0000,"publicationDate":"1961-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/TBMEL.1961.4322926","citationCount":"10","resultStr":"{\"title\":\"A Portable Miniature Transistorized Radio-Frequency Coupled Cardiac Pacemaker\",\"authors\":\"Hickman Dm, L. Geddes, H. Hoff, M. Hinds, A. G. Moore, C. K. Francis, T. Engen\",\"doi\":\"10.1109/TBMEL.1961.4322926\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A miniature, transistorized radio-frequency-coupled cardiac pacemaker was developed to eliminate wires penetrating the skin when electrodes are placed on the heart to drive it. The design also eliminates the need for totally implanting a pacemaker with its batteries. The stimulating impulse is transmitted via amplitude modulation to a tuned circuit and detector assembly implanted below the skin. The output of the detector is connected to electrodes directly on the heart, making external control of the heart rate possible. In operation, the pacemaker transmitter is placed on the surface of the body above the receiver implant. The size of the unit is 4×13/4 ×13/2 inches. It weighs three ounces.\",\"PeriodicalId\":86470,\"journal\":{\"name\":\"IRE transactions on bio-medical electronics\",\"volume\":\"8 1\",\"pages\":\"258-262\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1961-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/TBMEL.1961.4322926\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IRE transactions on bio-medical electronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TBMEL.1961.4322926\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IRE transactions on bio-medical electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TBMEL.1961.4322926","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

一种微型晶体管射频耦合心脏起搏器被开发出来,当电极放置在心脏上驱动它时,它可以消除穿过皮肤的电线。该设计还消除了完全植入带有电池的起搏器的需要。刺激脉冲通过振幅调制传输到植入皮肤下方的调谐电路和检测器组件。探测器的输出直接连接到心脏上的电极,使外部控制心率成为可能。在操作中,起搏器发射器被放置在身体表面接收器植入物的上方。单位尺寸为4×13/4 ×13/2英寸。它重三盎司。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Portable Miniature Transistorized Radio-Frequency Coupled Cardiac Pacemaker
A miniature, transistorized radio-frequency-coupled cardiac pacemaker was developed to eliminate wires penetrating the skin when electrodes are placed on the heart to drive it. The design also eliminates the need for totally implanting a pacemaker with its batteries. The stimulating impulse is transmitted via amplitude modulation to a tuned circuit and detector assembly implanted below the skin. The output of the detector is connected to electrodes directly on the heart, making external control of the heart rate possible. In operation, the pacemaker transmitter is placed on the surface of the body above the receiver implant. The size of the unit is 4×13/4 ×13/2 inches. It weighs three ounces.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信