{"title":"高频电容器损耗电导的直接测量","authors":"M. Boella","doi":"10.1109/JRPROC.1938.228310","DOIUrl":null,"url":null,"abstract":"A method of measuring the losses of a variable air condenser at high frequencies is described in which the condenser under test and the standard are connected in series as part of a tuned circuit. A radio-frequency voltage of resonant frequency is impressed on this circuit for a stated value of the standard. The unknown is then removed and the standard adjusted to resonance. The voltage across the tuned circuit is readjusted to its initial value by placing a conductance across the standard. The design of the standard condenser requires special considerations which are discussed. A self-biasing valve voltmeter, which is not critical to variations in power-supply voltage, is used. The results of measurements on several specimen condensers are given. A method of extending the measurements to higher frequencies is shown.","PeriodicalId":54574,"journal":{"name":"Proceedings of the Institute of Radio Engineers","volume":"26 1","pages":"421-432"},"PeriodicalIF":0.0000,"publicationDate":"1938-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/JRPROC.1938.228310","citationCount":"0","resultStr":"{\"title\":\"Direct Measurement of the Loss Conductance of Condensers at High Frequencies\",\"authors\":\"M. Boella\",\"doi\":\"10.1109/JRPROC.1938.228310\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A method of measuring the losses of a variable air condenser at high frequencies is described in which the condenser under test and the standard are connected in series as part of a tuned circuit. A radio-frequency voltage of resonant frequency is impressed on this circuit for a stated value of the standard. The unknown is then removed and the standard adjusted to resonance. The voltage across the tuned circuit is readjusted to its initial value by placing a conductance across the standard. The design of the standard condenser requires special considerations which are discussed. A self-biasing valve voltmeter, which is not critical to variations in power-supply voltage, is used. The results of measurements on several specimen condensers are given. A method of extending the measurements to higher frequencies is shown.\",\"PeriodicalId\":54574,\"journal\":{\"name\":\"Proceedings of the Institute of Radio Engineers\",\"volume\":\"26 1\",\"pages\":\"421-432\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1938-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/JRPROC.1938.228310\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Institute of Radio Engineers\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/JRPROC.1938.228310\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institute of Radio Engineers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/JRPROC.1938.228310","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Direct Measurement of the Loss Conductance of Condensers at High Frequencies
A method of measuring the losses of a variable air condenser at high frequencies is described in which the condenser under test and the standard are connected in series as part of a tuned circuit. A radio-frequency voltage of resonant frequency is impressed on this circuit for a stated value of the standard. The unknown is then removed and the standard adjusted to resonance. The voltage across the tuned circuit is readjusted to its initial value by placing a conductance across the standard. The design of the standard condenser requires special considerations which are discussed. A self-biasing valve voltmeter, which is not critical to variations in power-supply voltage, is used. The results of measurements on several specimen condensers are given. A method of extending the measurements to higher frequencies is shown.