{"title":"微电网直流电容在线调节动态电压恢复器的控制与运行","authors":"T. Kandil, Mohamed Adel Ahmed","doi":"10.1109/CJECE.2020.3002855","DOIUrl":null,"url":null,"abstract":"This article presents a dynamic voltage restorer (DVR) topology based on the adaptive noise canceling (ANC) technique, which can be used for both voltage compensation and harmonic mitigation. Furthermore, this article aims to investigate the DVR performance when installed in a microgrid (MG) during both normal operation of the utility and during utility disturbances. One of the main objectives of this article is to reduce the cost of inverter-based DVR by reducing both the size of the dc-link capacitor and rating of switching elements. The voltage of the dc-link capacitor is regulated to low voltage level using a transformer and a pulsewidth modulation (PWM) rectifier to achieve both effective voltage regulation and drawing a sinusoidal line current from the grid and thus not to contribute to the increase of the THD of the utility current. Furthermore, the voltage across the switches can be limited to low value by an adequate design of dc-link capacitor size, capacitor voltage, and sag level to be compensated. Finally, the effectiveness and fast response of the proposed DVR for the compensation of voltage disturbances and current harmonics is confirmed by simulation using MATLAB/Simulink during the steady-state and transient operations to analyze the performance of the scheme under different operating conditions.","PeriodicalId":55287,"journal":{"name":"Canadian Journal of Electrical and Computer Engineering-Revue Canadienne De Genie Electrique et Informatique","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/CJECE.2020.3002855","citationCount":"10","resultStr":"{\"title\":\"Control and Operation of Dynamic Voltage Restorer With Online Regulated DC-Link Capacitor in Microgrid System\",\"authors\":\"T. Kandil, Mohamed Adel Ahmed\",\"doi\":\"10.1109/CJECE.2020.3002855\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This article presents a dynamic voltage restorer (DVR) topology based on the adaptive noise canceling (ANC) technique, which can be used for both voltage compensation and harmonic mitigation. Furthermore, this article aims to investigate the DVR performance when installed in a microgrid (MG) during both normal operation of the utility and during utility disturbances. One of the main objectives of this article is to reduce the cost of inverter-based DVR by reducing both the size of the dc-link capacitor and rating of switching elements. The voltage of the dc-link capacitor is regulated to low voltage level using a transformer and a pulsewidth modulation (PWM) rectifier to achieve both effective voltage regulation and drawing a sinusoidal line current from the grid and thus not to contribute to the increase of the THD of the utility current. Furthermore, the voltage across the switches can be limited to low value by an adequate design of dc-link capacitor size, capacitor voltage, and sag level to be compensated. Finally, the effectiveness and fast response of the proposed DVR for the compensation of voltage disturbances and current harmonics is confirmed by simulation using MATLAB/Simulink during the steady-state and transient operations to analyze the performance of the scheme under different operating conditions.\",\"PeriodicalId\":55287,\"journal\":{\"name\":\"Canadian Journal of Electrical and Computer Engineering-Revue Canadienne De Genie Electrique et Informatique\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/CJECE.2020.3002855\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Canadian Journal of Electrical and Computer Engineering-Revue Canadienne De Genie Electrique et Informatique\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CJECE.2020.3002855\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian Journal of Electrical and Computer Engineering-Revue Canadienne De Genie Electrique et Informatique","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CJECE.2020.3002855","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
Control and Operation of Dynamic Voltage Restorer With Online Regulated DC-Link Capacitor in Microgrid System
This article presents a dynamic voltage restorer (DVR) topology based on the adaptive noise canceling (ANC) technique, which can be used for both voltage compensation and harmonic mitigation. Furthermore, this article aims to investigate the DVR performance when installed in a microgrid (MG) during both normal operation of the utility and during utility disturbances. One of the main objectives of this article is to reduce the cost of inverter-based DVR by reducing both the size of the dc-link capacitor and rating of switching elements. The voltage of the dc-link capacitor is regulated to low voltage level using a transformer and a pulsewidth modulation (PWM) rectifier to achieve both effective voltage regulation and drawing a sinusoidal line current from the grid and thus not to contribute to the increase of the THD of the utility current. Furthermore, the voltage across the switches can be limited to low value by an adequate design of dc-link capacitor size, capacitor voltage, and sag level to be compensated. Finally, the effectiveness and fast response of the proposed DVR for the compensation of voltage disturbances and current harmonics is confirmed by simulation using MATLAB/Simulink during the steady-state and transient operations to analyze the performance of the scheme under different operating conditions.
期刊介绍:
The Canadian Journal of Electrical and Computer Engineering (ISSN-0840-8688), issued quarterly, has been publishing high-quality refereed scientific papers in all areas of electrical and computer engineering since 1976