心脏功率的不同估计:与改变负荷条件的关系

M. Firstenberg, G. Armstrong, N. Greenberg, M.J. Garcia, J.D. Thomas
{"title":"心脏功率的不同估计:与改变负荷条件的关系","authors":"M. Firstenberg, G. Armstrong, N. Greenberg, M.J. Garcia, J.D. Thomas","doi":"10.1109/CIC.2002.1166872","DOIUrl":null,"url":null,"abstract":"Peak instantaneous power is a prognostic index of LV function but is difficult to measure. It is relatively load independent when corrected by preload (EDV/sup 2/). Easier to acquire power estimates have been proposed ncluding mean and simplified power. These require only echo Doppler flow and cuff pressures, but their relationship to invasively derived results has not been studied. Using a well-validated numerical model of the cardiovascular system, different estimates of power were compared for varying preload, afterload, and contractility. All power results were divided by EDV/sup 2/. Estimates of power correlate with peak power over a wide range of physiology. Corrected power estimates were independent of preload and afterload, but predictably increased with contractility. Different estimates of preload corrected power can be derived from non-invasively obtained variables and correlate with corrected peak instantaneous power.","PeriodicalId":80984,"journal":{"name":"Computers in cardiology","volume":"1 1","pages":"713-716"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/CIC.2002.1166872","citationCount":"2","resultStr":"{\"title\":\"Different estimates of cardiac power: relationship to altered loading conditions\",\"authors\":\"M. Firstenberg, G. Armstrong, N. Greenberg, M.J. Garcia, J.D. Thomas\",\"doi\":\"10.1109/CIC.2002.1166872\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Peak instantaneous power is a prognostic index of LV function but is difficult to measure. It is relatively load independent when corrected by preload (EDV/sup 2/). Easier to acquire power estimates have been proposed ncluding mean and simplified power. These require only echo Doppler flow and cuff pressures, but their relationship to invasively derived results has not been studied. Using a well-validated numerical model of the cardiovascular system, different estimates of power were compared for varying preload, afterload, and contractility. All power results were divided by EDV/sup 2/. Estimates of power correlate with peak power over a wide range of physiology. Corrected power estimates were independent of preload and afterload, but predictably increased with contractility. Different estimates of preload corrected power can be derived from non-invasively obtained variables and correlate with corrected peak instantaneous power.\",\"PeriodicalId\":80984,\"journal\":{\"name\":\"Computers in cardiology\",\"volume\":\"1 1\",\"pages\":\"713-716\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/CIC.2002.1166872\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computers in cardiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIC.2002.1166872\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computers in cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.2002.1166872","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

峰值瞬时功率是左室功能的预后指标,但测量难度较大。当通过预紧力(EDV/sup 2/)校正时,它相对独立于负载。提出了更容易获得的功率估计方法,包括平均功率和简化功率。这些只需要回波多普勒血流和袖带压力,但它们与侵入性衍生结果的关系尚未研究。使用经过验证的心血管系统数值模型,比较了不同的预负荷、后负荷和收缩力对功率的不同估计。所有功率结果除以EDV/sup 2/。在广泛的生理范围内,功率估计与峰值功率相关。修正后的功率估计值与预负荷和后负荷无关,但可预测地随着收缩性而增加。预载校正功率的不同估计可以从非侵入性获得的变量中得出,并与校正的峰值瞬时功率相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Different estimates of cardiac power: relationship to altered loading conditions
Peak instantaneous power is a prognostic index of LV function but is difficult to measure. It is relatively load independent when corrected by preload (EDV/sup 2/). Easier to acquire power estimates have been proposed ncluding mean and simplified power. These require only echo Doppler flow and cuff pressures, but their relationship to invasively derived results has not been studied. Using a well-validated numerical model of the cardiovascular system, different estimates of power were compared for varying preload, afterload, and contractility. All power results were divided by EDV/sup 2/. Estimates of power correlate with peak power over a wide range of physiology. Corrected power estimates were independent of preload and afterload, but predictably increased with contractility. Different estimates of preload corrected power can be derived from non-invasively obtained variables and correlate with corrected peak instantaneous power.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信