应力测试心电图记录中ST/HR迟滞的鲁棒测量

R. Bailón, S. Olmos, P. Serrano, J. García, P. Laguna
{"title":"应力测试心电图记录中ST/HR迟滞的鲁棒测量","authors":"R. Bailón, S. Olmos, P. Serrano, J. García, P. Laguna","doi":"10.1109/CIC.2002.1166775","DOIUrl":null,"url":null,"abstract":"In stress test ECG analysis, the so-called ST/HR hysteresis has recently been suggested to improve coronary artery disease (CAD) diagnosis. This parameter is estimated from the ST versus HR diagram including exercise and recovery phases. Unluckily, ST measurements are adversely affected by noise during the test. In this study we propose a method to automatically estimate the ST/HR hysteresis, incorporating multiple stage noise attenuation. The method is based on averaging and rejection of noisy beats. Evaluation is done on simulated exercise test recordings, constructed from real ECG averaged beats adding actual noise from stress test records. Results on a total of 216 different records, with RMS noise levels ranging from 114 to 979 /spl mu/V, give a reduction in estimation error in the ST/HR diagram of 77.98% (from 168 to 37 /spl mu/V) in mean and of 76.38% (from 271 to 63 /spl mu/V) in standard deviation. This method may be considered as a suitable and robust tool for reliable ST/HR hysteresis estimation.","PeriodicalId":80984,"journal":{"name":"Computers in cardiology","volume":"1 1","pages":"329-332"},"PeriodicalIF":0.0000,"publicationDate":"2002-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/CIC.2002.1166775","citationCount":"13","resultStr":"{\"title\":\"Robust measure of ST/HR hysteresis in stress test ECG recordings\",\"authors\":\"R. Bailón, S. Olmos, P. Serrano, J. García, P. Laguna\",\"doi\":\"10.1109/CIC.2002.1166775\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In stress test ECG analysis, the so-called ST/HR hysteresis has recently been suggested to improve coronary artery disease (CAD) diagnosis. This parameter is estimated from the ST versus HR diagram including exercise and recovery phases. Unluckily, ST measurements are adversely affected by noise during the test. In this study we propose a method to automatically estimate the ST/HR hysteresis, incorporating multiple stage noise attenuation. The method is based on averaging and rejection of noisy beats. Evaluation is done on simulated exercise test recordings, constructed from real ECG averaged beats adding actual noise from stress test records. Results on a total of 216 different records, with RMS noise levels ranging from 114 to 979 /spl mu/V, give a reduction in estimation error in the ST/HR diagram of 77.98% (from 168 to 37 /spl mu/V) in mean and of 76.38% (from 271 to 63 /spl mu/V) in standard deviation. This method may be considered as a suitable and robust tool for reliable ST/HR hysteresis estimation.\",\"PeriodicalId\":80984,\"journal\":{\"name\":\"Computers in cardiology\",\"volume\":\"1 1\",\"pages\":\"329-332\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-09-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/CIC.2002.1166775\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computers in cardiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIC.2002.1166775\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computers in cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.2002.1166775","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

摘要

在压力测试心电图分析中,所谓的ST/HR迟滞最近被建议用于改善冠状动脉疾病(CAD)的诊断。这个参数是从包括运动和恢复阶段的ST与HR图中估计出来的。不幸的是,测试期间的ST测量受到噪声的不利影响。在这项研究中,我们提出了一种自动估计ST/HR滞后的方法,并结合了多级噪声衰减。该方法基于噪声节拍的平均和抑制。对模拟运动测试记录进行评估,该记录由真实的心电平均心跳和压力测试记录的实际噪声组成。结果表明,在RMS噪声水平范围为114 - 979 /spl mu/V的216条不同记录上,ST/HR图的估计误差平均降低77.98%(从168 - 37 /spl mu/V),标准差降低76.38%(从271 - 63 /spl mu/V)。该方法可被认为是一种可靠的ST/HR滞后估计的合适且稳健的工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Robust measure of ST/HR hysteresis in stress test ECG recordings
In stress test ECG analysis, the so-called ST/HR hysteresis has recently been suggested to improve coronary artery disease (CAD) diagnosis. This parameter is estimated from the ST versus HR diagram including exercise and recovery phases. Unluckily, ST measurements are adversely affected by noise during the test. In this study we propose a method to automatically estimate the ST/HR hysteresis, incorporating multiple stage noise attenuation. The method is based on averaging and rejection of noisy beats. Evaluation is done on simulated exercise test recordings, constructed from real ECG averaged beats adding actual noise from stress test records. Results on a total of 216 different records, with RMS noise levels ranging from 114 to 979 /spl mu/V, give a reduction in estimation error in the ST/HR diagram of 77.98% (from 168 to 37 /spl mu/V) in mean and of 76.38% (from 271 to 63 /spl mu/V) in standard deviation. This method may be considered as a suitable and robust tool for reliable ST/HR hysteresis estimation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信