自动测量颈动脉直径和壁厚超声图像

M. A. Gutierrez, P. E. Pilon, S. Lage, L. Kopel, R. T. Carvalho, Sergio Shiguemi Furuie
{"title":"自动测量颈动脉直径和壁厚超声图像","authors":"M. A. Gutierrez, P. E. Pilon, S. Lage, L. Kopel, R. T. Carvalho, Sergio Shiguemi Furuie","doi":"10.1109/CIC.2002.1166783","DOIUrl":null,"url":null,"abstract":"Carotid vessel ultrasound imaging is a reliable noninvasive technique to measure the arterial morphology. Lumen Diameter (LD), intima-media thickness (IMT) of the far wall, and plaque presence can be reliably determined using B-mode ultrasound. In order to measure the carotid IMT as well as any other more complex quantitative indices of vessel morphology, it is necessary to identify lumen-intima and media-adventitia borders in the ultrasound images. In this paper we describe an automatic approach to measure LD and IMT based on an active contour technique improved by a multiresolution analysis. The measurements of LD and IMT were compared to manual tracing of the vessels border in terms of coefficients of variability (CV) and correlation (R). The results have shown that the method is a reliable and reproducible way of assessing the LD and far wall IMT in the carotid artery.","PeriodicalId":80984,"journal":{"name":"Computers in cardiology","volume":"1 1","pages":"359-362"},"PeriodicalIF":0.0000,"publicationDate":"2002-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/CIC.2002.1166783","citationCount":"92","resultStr":"{\"title\":\"Automatic measurement of carotid diameter and wall thickness in ultrasound images\",\"authors\":\"M. A. Gutierrez, P. E. Pilon, S. Lage, L. Kopel, R. T. Carvalho, Sergio Shiguemi Furuie\",\"doi\":\"10.1109/CIC.2002.1166783\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Carotid vessel ultrasound imaging is a reliable noninvasive technique to measure the arterial morphology. Lumen Diameter (LD), intima-media thickness (IMT) of the far wall, and plaque presence can be reliably determined using B-mode ultrasound. In order to measure the carotid IMT as well as any other more complex quantitative indices of vessel morphology, it is necessary to identify lumen-intima and media-adventitia borders in the ultrasound images. In this paper we describe an automatic approach to measure LD and IMT based on an active contour technique improved by a multiresolution analysis. The measurements of LD and IMT were compared to manual tracing of the vessels border in terms of coefficients of variability (CV) and correlation (R). The results have shown that the method is a reliable and reproducible way of assessing the LD and far wall IMT in the carotid artery.\",\"PeriodicalId\":80984,\"journal\":{\"name\":\"Computers in cardiology\",\"volume\":\"1 1\",\"pages\":\"359-362\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-09-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/CIC.2002.1166783\",\"citationCount\":\"92\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computers in cardiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIC.2002.1166783\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computers in cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.2002.1166783","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 92

摘要

颈动脉血管超声成像是一种可靠的无创技术来测量动脉形态。b超可以可靠地确定远壁管腔直径(LD)、内膜-中膜厚度(IMT)和斑块的存在。为了测量颈动脉IMT以及任何其他更复杂的血管形态学定量指标,有必要在超声图像中识别管腔内膜和中膜外膜边界。本文描述了一种基于多分辨率分析改进的主动轮廓技术的LD和IMT自动测量方法。在变异系数(CV)和相关系数(R)方面,将LD和IMT的测量与手工追踪血管边界进行比较。结果表明,该方法是评估颈动脉LD和远壁IMT的可靠且可重复的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Automatic measurement of carotid diameter and wall thickness in ultrasound images
Carotid vessel ultrasound imaging is a reliable noninvasive technique to measure the arterial morphology. Lumen Diameter (LD), intima-media thickness (IMT) of the far wall, and plaque presence can be reliably determined using B-mode ultrasound. In order to measure the carotid IMT as well as any other more complex quantitative indices of vessel morphology, it is necessary to identify lumen-intima and media-adventitia borders in the ultrasound images. In this paper we describe an automatic approach to measure LD and IMT based on an active contour technique improved by a multiresolution analysis. The measurements of LD and IMT were compared to manual tracing of the vessels border in terms of coefficients of variability (CV) and correlation (R). The results have shown that the method is a reliable and reproducible way of assessing the LD and far wall IMT in the carotid artery.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信