R. van Malderen, H. De Backer, A. Delcloo, M. Allaart
{"title":"通过与附近De Bilt的比较,在Uccle臭氧探测资料中识别对流层高层异常臭氧的来源","authors":"R. van Malderen, H. De Backer, A. Delcloo, M. Allaart","doi":"10.1080/07055900.2014.886552","DOIUrl":null,"url":null,"abstract":"Abstract The ozonesonde stations at Uccle (Belgium) and De Bilt (Netherlands), separated by only 175 km, offer a unique opportunity to test the influence of different ozonesonde types and different correction strategies, as well as to detect the presence of inhomogeneities in the ozonesonde time series resulting from changes in sounding equipment (solution, radiosonde, ozonesonde, interface, sounding software, etc.). In particular, we highlight a 2.5 year period (beginning of 2007 to mid-2009) of anomalous high tropospheric ozone values measured by ozonesondes at Uccle and compare these with the observations from De Bilt. Because the ozone deviations are only observed in the free troposphere where ozone concentrations are relatively low, and not in the boundary layer or the stratosphere, this issue is directly related to the sensitivity of ozonesondes. Therefore, the effect of every instrumental change, even though small, during this 2.5 year anomalous period is analyzed considering a change in the radiosounding equipment, different ozonesonde batches, operational differences at the stations, differences on ascent and descent during the anomalous period; an environmental cause is also examined. Unfortunately, one single, specific cause for the observed high tropospheric ozone values at Uccle could not be identified. There are two explanations consistent with the observations and not ruled out by the analysis here: 1) the majority of the ozonesondes used at Uccle between March 2007 and August 2009 needed longer conditioning of their sensors and, therefore, behaved more accurately at low ozone concentrations during their descent or when used a second time, and 2) an environmental origin arising from a local difference in the air mass between Uccle and De Bilt and between the ascent and descent.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2015-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/07055900.2014.886552","citationCount":"3","resultStr":"{\"title\":\"Identifying the Origin of Anomalous High Tropospheric Ozone in the Ozonesonde Data at Uccle by Comparison with Nearby De Bilt\",\"authors\":\"R. van Malderen, H. De Backer, A. Delcloo, M. Allaart\",\"doi\":\"10.1080/07055900.2014.886552\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The ozonesonde stations at Uccle (Belgium) and De Bilt (Netherlands), separated by only 175 km, offer a unique opportunity to test the influence of different ozonesonde types and different correction strategies, as well as to detect the presence of inhomogeneities in the ozonesonde time series resulting from changes in sounding equipment (solution, radiosonde, ozonesonde, interface, sounding software, etc.). In particular, we highlight a 2.5 year period (beginning of 2007 to mid-2009) of anomalous high tropospheric ozone values measured by ozonesondes at Uccle and compare these with the observations from De Bilt. Because the ozone deviations are only observed in the free troposphere where ozone concentrations are relatively low, and not in the boundary layer or the stratosphere, this issue is directly related to the sensitivity of ozonesondes. Therefore, the effect of every instrumental change, even though small, during this 2.5 year anomalous period is analyzed considering a change in the radiosounding equipment, different ozonesonde batches, operational differences at the stations, differences on ascent and descent during the anomalous period; an environmental cause is also examined. Unfortunately, one single, specific cause for the observed high tropospheric ozone values at Uccle could not be identified. There are two explanations consistent with the observations and not ruled out by the analysis here: 1) the majority of the ozonesondes used at Uccle between March 2007 and August 2009 needed longer conditioning of their sensors and, therefore, behaved more accurately at low ozone concentrations during their descent or when used a second time, and 2) an environmental origin arising from a local difference in the air mass between Uccle and De Bilt and between the ascent and descent.\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2015-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/07055900.2014.886552\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"89\",\"ListUrlMain\":\"https://doi.org/10.1080/07055900.2014.886552\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"89","ListUrlMain":"https://doi.org/10.1080/07055900.2014.886552","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Identifying the Origin of Anomalous High Tropospheric Ozone in the Ozonesonde Data at Uccle by Comparison with Nearby De Bilt
Abstract The ozonesonde stations at Uccle (Belgium) and De Bilt (Netherlands), separated by only 175 km, offer a unique opportunity to test the influence of different ozonesonde types and different correction strategies, as well as to detect the presence of inhomogeneities in the ozonesonde time series resulting from changes in sounding equipment (solution, radiosonde, ozonesonde, interface, sounding software, etc.). In particular, we highlight a 2.5 year period (beginning of 2007 to mid-2009) of anomalous high tropospheric ozone values measured by ozonesondes at Uccle and compare these with the observations from De Bilt. Because the ozone deviations are only observed in the free troposphere where ozone concentrations are relatively low, and not in the boundary layer or the stratosphere, this issue is directly related to the sensitivity of ozonesondes. Therefore, the effect of every instrumental change, even though small, during this 2.5 year anomalous period is analyzed considering a change in the radiosounding equipment, different ozonesonde batches, operational differences at the stations, differences on ascent and descent during the anomalous period; an environmental cause is also examined. Unfortunately, one single, specific cause for the observed high tropospheric ozone values at Uccle could not be identified. There are two explanations consistent with the observations and not ruled out by the analysis here: 1) the majority of the ozonesondes used at Uccle between March 2007 and August 2009 needed longer conditioning of their sensors and, therefore, behaved more accurately at low ozone concentrations during their descent or when used a second time, and 2) an environmental origin arising from a local difference in the air mass between Uccle and De Bilt and between the ascent and descent.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.