通过与附近De Bilt的比较,在Uccle臭氧探测资料中识别对流层高层异常臭氧的来源

IF 1.6 4区 地球科学 Q4 METEOROLOGY & ATMOSPHERIC SCIENCES
R. van Malderen, H. De Backer, A. Delcloo, M. Allaart
{"title":"通过与附近De Bilt的比较,在Uccle臭氧探测资料中识别对流层高层异常臭氧的来源","authors":"R. van Malderen, H. De Backer, A. Delcloo, M. Allaart","doi":"10.1080/07055900.2014.886552","DOIUrl":null,"url":null,"abstract":"Abstract The ozonesonde stations at Uccle (Belgium) and De Bilt (Netherlands), separated by only 175 km, offer a unique opportunity to test the influence of different ozonesonde types and different correction strategies, as well as to detect the presence of inhomogeneities in the ozonesonde time series resulting from changes in sounding equipment (solution, radiosonde, ozonesonde, interface, sounding software, etc.). In particular, we highlight a 2.5 year period (beginning of 2007 to mid-2009) of anomalous high tropospheric ozone values measured by ozonesondes at Uccle and compare these with the observations from De Bilt. Because the ozone deviations are only observed in the free troposphere where ozone concentrations are relatively low, and not in the boundary layer or the stratosphere, this issue is directly related to the sensitivity of ozonesondes. Therefore, the effect of every instrumental change, even though small, during this 2.5 year anomalous period is analyzed considering a change in the radiosounding equipment, different ozonesonde batches, operational differences at the stations, differences on ascent and descent during the anomalous period; an environmental cause is also examined. Unfortunately, one single, specific cause for the observed high tropospheric ozone values at Uccle could not be identified. There are two explanations consistent with the observations and not ruled out by the analysis here: 1) the majority of the ozonesondes used at Uccle between March 2007 and August 2009 needed longer conditioning of their sensors and, therefore, behaved more accurately at low ozone concentrations during their descent or when used a second time, and 2) an environmental origin arising from a local difference in the air mass between Uccle and De Bilt and between the ascent and descent.","PeriodicalId":55434,"journal":{"name":"Atmosphere-Ocean","volume":"36 1","pages":"102 - 116"},"PeriodicalIF":1.6000,"publicationDate":"2015-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/07055900.2014.886552","citationCount":"3","resultStr":"{\"title\":\"Identifying the Origin of Anomalous High Tropospheric Ozone in the Ozonesonde Data at Uccle by Comparison with Nearby De Bilt\",\"authors\":\"R. van Malderen, H. De Backer, A. Delcloo, M. Allaart\",\"doi\":\"10.1080/07055900.2014.886552\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The ozonesonde stations at Uccle (Belgium) and De Bilt (Netherlands), separated by only 175 km, offer a unique opportunity to test the influence of different ozonesonde types and different correction strategies, as well as to detect the presence of inhomogeneities in the ozonesonde time series resulting from changes in sounding equipment (solution, radiosonde, ozonesonde, interface, sounding software, etc.). In particular, we highlight a 2.5 year period (beginning of 2007 to mid-2009) of anomalous high tropospheric ozone values measured by ozonesondes at Uccle and compare these with the observations from De Bilt. Because the ozone deviations are only observed in the free troposphere where ozone concentrations are relatively low, and not in the boundary layer or the stratosphere, this issue is directly related to the sensitivity of ozonesondes. Therefore, the effect of every instrumental change, even though small, during this 2.5 year anomalous period is analyzed considering a change in the radiosounding equipment, different ozonesonde batches, operational differences at the stations, differences on ascent and descent during the anomalous period; an environmental cause is also examined. Unfortunately, one single, specific cause for the observed high tropospheric ozone values at Uccle could not be identified. There are two explanations consistent with the observations and not ruled out by the analysis here: 1) the majority of the ozonesondes used at Uccle between March 2007 and August 2009 needed longer conditioning of their sensors and, therefore, behaved more accurately at low ozone concentrations during their descent or when used a second time, and 2) an environmental origin arising from a local difference in the air mass between Uccle and De Bilt and between the ascent and descent.\",\"PeriodicalId\":55434,\"journal\":{\"name\":\"Atmosphere-Ocean\",\"volume\":\"36 1\",\"pages\":\"102 - 116\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2015-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/07055900.2014.886552\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Atmosphere-Ocean\",\"FirstCategoryId\":\"89\",\"ListUrlMain\":\"https://doi.org/10.1080/07055900.2014.886552\",\"RegionNum\":4,\"RegionCategory\":\"地球科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"METEOROLOGY & ATMOSPHERIC SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Atmosphere-Ocean","FirstCategoryId":"89","ListUrlMain":"https://doi.org/10.1080/07055900.2014.886552","RegionNum":4,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"METEOROLOGY & ATMOSPHERIC SCIENCES","Score":null,"Total":0}
引用次数: 3

摘要

比利时Uccle和荷兰De Bilt的臭氧探空站相距仅175公里,提供了一个独特的机会来测试不同臭氧探空类型和不同校正策略的影响,以及检测由于探测设备(溶液、无线电探空仪、臭氧探空仪、接口、探测软件等)变化而导致的臭氧探空时间序列不均匀性的存在。特别地,我们强调了2.5年期间(2007年初至2009年年中)由Uccle的臭氧仪测量到的对流层臭氧异常高值,并将其与De Bilt的观测结果进行了比较。由于臭氧偏差只在臭氧浓度相对较低的自由对流层中观测到,而在边界层或平流层中没有观测到,因此这一问题与臭氧探测器的灵敏度直接相关。因此,在这2.5年的异常期间,考虑到无线电探测设备的变化、不同的臭氧探空批次、台站的操作差异、异常期间上升和下降的差异,分析了每一次仪器变化的影响,即使很小;环境因素也被研究。不幸的是,无法确定在ucle观测到的高对流层臭氧值的一个单一的具体原因。有两种解释与观测一致,不排除分析:1)大部分臭氧探测仪使用Uccle 2007年3月和2009年8月之间需要长调节传感器和,因此,表现得更准确地在低臭氧浓度下降或第二次使用时,和2)环境产生的起源从当地空气质量差Uccle和德印度之间之间的上升和下降。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Identifying the Origin of Anomalous High Tropospheric Ozone in the Ozonesonde Data at Uccle by Comparison with Nearby De Bilt
Abstract The ozonesonde stations at Uccle (Belgium) and De Bilt (Netherlands), separated by only 175 km, offer a unique opportunity to test the influence of different ozonesonde types and different correction strategies, as well as to detect the presence of inhomogeneities in the ozonesonde time series resulting from changes in sounding equipment (solution, radiosonde, ozonesonde, interface, sounding software, etc.). In particular, we highlight a 2.5 year period (beginning of 2007 to mid-2009) of anomalous high tropospheric ozone values measured by ozonesondes at Uccle and compare these with the observations from De Bilt. Because the ozone deviations are only observed in the free troposphere where ozone concentrations are relatively low, and not in the boundary layer or the stratosphere, this issue is directly related to the sensitivity of ozonesondes. Therefore, the effect of every instrumental change, even though small, during this 2.5 year anomalous period is analyzed considering a change in the radiosounding equipment, different ozonesonde batches, operational differences at the stations, differences on ascent and descent during the anomalous period; an environmental cause is also examined. Unfortunately, one single, specific cause for the observed high tropospheric ozone values at Uccle could not be identified. There are two explanations consistent with the observations and not ruled out by the analysis here: 1) the majority of the ozonesondes used at Uccle between March 2007 and August 2009 needed longer conditioning of their sensors and, therefore, behaved more accurately at low ozone concentrations during their descent or when used a second time, and 2) an environmental origin arising from a local difference in the air mass between Uccle and De Bilt and between the ascent and descent.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Atmosphere-Ocean
Atmosphere-Ocean 地学-海洋学
CiteScore
2.50
自引率
16.70%
发文量
33
审稿时长
>12 weeks
期刊介绍: Atmosphere-Ocean is the principal scientific journal of the Canadian Meteorological and Oceanographic Society (CMOS). It contains results of original research, survey articles, notes and comments on published papers in all fields of the atmospheric, oceanographic and hydrological sciences. Arctic, coastal and mid- to high-latitude regions are areas of particular interest. Applied or fundamental research contributions in English or French on the following topics are welcomed: climate and climatology; observation technology, remote sensing; forecasting, modelling, numerical methods; physics, dynamics, chemistry, biogeochemistry; boundary layers, pollution, aerosols; circulation, cloud physics, hydrology, air-sea interactions; waves, ice, energy exchange and related environmental topics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信