{"title":"使用单音和二元多重听觉稳态反应技术确定正常听力受试者的阈值","authors":"A. Herdman, D. Stapells","doi":"10.1080/010503901750069563","DOIUrl":null,"url":null,"abstract":"Auditory steady-state responses (ASSRs) were elicited by presenting single or multiple, 77-105 Hz amplitude-modulated 0.5, 1, 2, and 4 kHz tones to one or both ears. Objectives of this study were to (i) replicate and extend previous multiple ASSR studies in a quiet double-walled sound booth, and (ii) discover differences (if any) between thresholds assessed in monotic and dichotic conditions, which ranged between 15 and 22 dB SPL. The present study's behavioural and ASSR thresholds are 0-10 dB lower (better) than results of previous monotic studies. Further, there are no significant differences in ASSR thresholds between dichotic and monotic stimulus conditions. Therefore, dichotic multiple AM tone stimulation does not produce a change in the ASSR that affects threshold estimation in a clinically significant manner. Thus, at least for detecting normal hearing, the dichotic multiple ASSR technique is a feasible method for estimating hearing thresholds that would substantially reduce recording time compared to conventional single-stimulus techniques.","PeriodicalId":76516,"journal":{"name":"Scandinavian audiology","volume":"30 1","pages":"41 - 49"},"PeriodicalIF":0.0000,"publicationDate":"2001-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/010503901750069563","citationCount":"153","resultStr":"{\"title\":\"Thresholds determined using the monotic and dichotic multiple auditory steady-state response technique in normal-hearing subjects\",\"authors\":\"A. Herdman, D. Stapells\",\"doi\":\"10.1080/010503901750069563\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Auditory steady-state responses (ASSRs) were elicited by presenting single or multiple, 77-105 Hz amplitude-modulated 0.5, 1, 2, and 4 kHz tones to one or both ears. Objectives of this study were to (i) replicate and extend previous multiple ASSR studies in a quiet double-walled sound booth, and (ii) discover differences (if any) between thresholds assessed in monotic and dichotic conditions, which ranged between 15 and 22 dB SPL. The present study's behavioural and ASSR thresholds are 0-10 dB lower (better) than results of previous monotic studies. Further, there are no significant differences in ASSR thresholds between dichotic and monotic stimulus conditions. Therefore, dichotic multiple AM tone stimulation does not produce a change in the ASSR that affects threshold estimation in a clinically significant manner. Thus, at least for detecting normal hearing, the dichotic multiple ASSR technique is a feasible method for estimating hearing thresholds that would substantially reduce recording time compared to conventional single-stimulus techniques.\",\"PeriodicalId\":76516,\"journal\":{\"name\":\"Scandinavian audiology\",\"volume\":\"30 1\",\"pages\":\"41 - 49\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/010503901750069563\",\"citationCount\":\"153\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Scandinavian audiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/010503901750069563\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scandinavian audiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/010503901750069563","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 153
摘要
听觉稳态反应(ASSRs)是通过向一只或两只耳朵呈现单个或多个77-105 Hz的调幅0.5、1、2和4 kHz的音调引起的。本研究的目的是:(1)在一个安静的双壁声室中复制和扩展以前的多个ASSR研究,(2)发现在单一和二元条件下评估的阈值之间的差异(如果有的话),范围在15和22 dB SPL之间。本研究的行为和ASSR阈值比以往的单一研究结果低0-10 dB(更好)。此外,在二元刺激和单一刺激条件下,ASSR阈值没有显著差异。因此,双重多重AM音调刺激不会产生影响阈值估计的ASSR变化。因此,至少对于检测正常听力而言,二元多重ASSR技术是估计听力阈值的可行方法,与传统的单刺激技术相比,它将大大减少记录时间。
Thresholds determined using the monotic and dichotic multiple auditory steady-state response technique in normal-hearing subjects
Auditory steady-state responses (ASSRs) were elicited by presenting single or multiple, 77-105 Hz amplitude-modulated 0.5, 1, 2, and 4 kHz tones to one or both ears. Objectives of this study were to (i) replicate and extend previous multiple ASSR studies in a quiet double-walled sound booth, and (ii) discover differences (if any) between thresholds assessed in monotic and dichotic conditions, which ranged between 15 and 22 dB SPL. The present study's behavioural and ASSR thresholds are 0-10 dB lower (better) than results of previous monotic studies. Further, there are no significant differences in ASSR thresholds between dichotic and monotic stimulus conditions. Therefore, dichotic multiple AM tone stimulation does not produce a change in the ASSR that affects threshold estimation in a clinically significant manner. Thus, at least for detecting normal hearing, the dichotic multiple ASSR technique is a feasible method for estimating hearing thresholds that would substantially reduce recording time compared to conventional single-stimulus techniques.