Yotam Almagor, S. Eventov-Friedman, A. Nir, Awad Sror, Ann Saada
{"title":"肌钙蛋白- t在干血斑和干血浆斑的测量:一项初步研究","authors":"Yotam Almagor, S. Eventov-Friedman, A. Nir, Awad Sror, Ann Saada","doi":"10.1055/s-0036-1586475","DOIUrl":null,"url":null,"abstract":"Abstract Troponin-T (TnT) is a biomarker for cardiac insult, but its significance as a cardiac biomarker in neonates is unclear. A method for measuring TnT in dried blood spots (DBS), which are used worldwide for neonatal screening, will enable access to a very large potential database. We tested concentrations of TnT in dried blood and dried plasma and compared results to the TnT concentrations in the original fresh blood. Troponin results in dried blood were significantly changed and did not allow sufficient test resolution. In contrast, troponin concentrations in dried plasma correlated well to those of all original samples tested. Our preliminary results suggest that TnT can accurately be measured in dried plasma, but TnT concentrations in dried blood are detectable only if troponin values are significantly elevated.","PeriodicalId":89425,"journal":{"name":"Journal of pediatric biochemistry","volume":"04 1","pages":"153 - 157"},"PeriodicalIF":0.0000,"publicationDate":"2014-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measurement of troponin-T in dried blood spots and dried plasma spots: A pilot study\",\"authors\":\"Yotam Almagor, S. Eventov-Friedman, A. Nir, Awad Sror, Ann Saada\",\"doi\":\"10.1055/s-0036-1586475\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Troponin-T (TnT) is a biomarker for cardiac insult, but its significance as a cardiac biomarker in neonates is unclear. A method for measuring TnT in dried blood spots (DBS), which are used worldwide for neonatal screening, will enable access to a very large potential database. We tested concentrations of TnT in dried blood and dried plasma and compared results to the TnT concentrations in the original fresh blood. Troponin results in dried blood were significantly changed and did not allow sufficient test resolution. In contrast, troponin concentrations in dried plasma correlated well to those of all original samples tested. Our preliminary results suggest that TnT can accurately be measured in dried plasma, but TnT concentrations in dried blood are detectable only if troponin values are significantly elevated.\",\"PeriodicalId\":89425,\"journal\":{\"name\":\"Journal of pediatric biochemistry\",\"volume\":\"04 1\",\"pages\":\"153 - 157\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of pediatric biochemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0036-1586475\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of pediatric biochemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0036-1586475","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
肌钙蛋白- t (TnT)是心脏损伤的生物标志物,但其作为新生儿心脏生物标志物的意义尚不清楚。在全世界用于新生儿筛查的干血斑(DBS)中测量TnT的方法将使访问一个非常大的潜在数据库成为可能。我们测试了干血和干血浆中的TnT浓度,并将结果与原始新鲜血液中的TnT浓度进行了比较。肌钙蛋白结果在干血显著改变,不允许足够的测试分辨率。相比之下,干燥血浆中的肌钙蛋白浓度与所有原始测试样品的浓度相关性良好。我们的初步结果表明,在干燥血浆中可以准确地测量TnT,但只有当肌钙蛋白值显著升高时,才能检测到干燥血液中的TnT浓度。
Measurement of troponin-T in dried blood spots and dried plasma spots: A pilot study
Abstract Troponin-T (TnT) is a biomarker for cardiac insult, but its significance as a cardiac biomarker in neonates is unclear. A method for measuring TnT in dried blood spots (DBS), which are used worldwide for neonatal screening, will enable access to a very large potential database. We tested concentrations of TnT in dried blood and dried plasma and compared results to the TnT concentrations in the original fresh blood. Troponin results in dried blood were significantly changed and did not allow sufficient test resolution. In contrast, troponin concentrations in dried plasma correlated well to those of all original samples tested. Our preliminary results suggest that TnT can accurately be measured in dried plasma, but TnT concentrations in dried blood are detectable only if troponin values are significantly elevated.