用振荡式密度法和折射法测定绝对盐度

Q3 Engineering
A. Furtado, Andreia Napoleão, J. Pereira, S. Moura, R. Quendera, O. Pellegrino
{"title":"用振荡式密度法和折射法测定绝对盐度","authors":"A. Furtado, Andreia Napoleão, J. Pereira, S. Moura, R. Quendera, O. Pellegrino","doi":"10.1051/ijmqe/2022007","DOIUrl":null,"url":null,"abstract":"The determination of salinity values from SI traceable densimetry and refractometry measurement results enable SI traceability of the former. In this work, a short study of the metrological compatibility of salinity determinations via these two methods for sodium chloride in ultrapure water solutions and two different standard seawaters (OSIL and ERM) solutions, in the [35.0; 215.0] g kg−1 interval, is presented. It evidenced the metrological compatibility of the salinity determinations in the referred interval. The largest salinity values enabled to test the matrix effect upon the determinations and concluded the preferable use of densimetry technique, when occurring.","PeriodicalId":38371,"journal":{"name":"International Journal of Metrology and Quality Engineering","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Absolute salinity determination by oscillation-type densimetry and refractometry\",\"authors\":\"A. Furtado, Andreia Napoleão, J. Pereira, S. Moura, R. Quendera, O. Pellegrino\",\"doi\":\"10.1051/ijmqe/2022007\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The determination of salinity values from SI traceable densimetry and refractometry measurement results enable SI traceability of the former. In this work, a short study of the metrological compatibility of salinity determinations via these two methods for sodium chloride in ultrapure water solutions and two different standard seawaters (OSIL and ERM) solutions, in the [35.0; 215.0] g kg−1 interval, is presented. It evidenced the metrological compatibility of the salinity determinations in the referred interval. The largest salinity values enabled to test the matrix effect upon the determinations and concluded the preferable use of densimetry technique, when occurring.\",\"PeriodicalId\":38371,\"journal\":{\"name\":\"International Journal of Metrology and Quality Engineering\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Metrology and Quality Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1051/ijmqe/2022007\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Metrology and Quality Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/ijmqe/2022007","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

摘要

从SI可追溯的密度测量和折射测量结果中确定盐度值使SI可追溯性成为可能。在这项工作中,通过这两种方法在超纯水溶液和两种不同标准海水(OSIL和ERM)溶液中测定氯化钠的盐度的计量兼容性的简短研究,在[35.0;215.0] g kg−1区间,给出。证明了所述区间内盐度测定的计量相容性。当出现最大盐度值时,可以测试基质对测定的影响,并得出密度测定技术的优选使用结论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Absolute salinity determination by oscillation-type densimetry and refractometry
The determination of salinity values from SI traceable densimetry and refractometry measurement results enable SI traceability of the former. In this work, a short study of the metrological compatibility of salinity determinations via these two methods for sodium chloride in ultrapure water solutions and two different standard seawaters (OSIL and ERM) solutions, in the [35.0; 215.0] g kg−1 interval, is presented. It evidenced the metrological compatibility of the salinity determinations in the referred interval. The largest salinity values enabled to test the matrix effect upon the determinations and concluded the preferable use of densimetry technique, when occurring.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Metrology and Quality Engineering
International Journal of Metrology and Quality Engineering Engineering-Safety, Risk, Reliability and Quality
CiteScore
1.70
自引率
0.00%
发文量
8
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信