{"title":"T-S模糊高超声速飞行器模型执行器故障检测:基于T-S模糊的H∞滑模观测器方法","authors":"Meijie Liu;Ping Luo;Changhua Hu;Rui Guo;Xiaoxiang Hu","doi":"10.1109/JMASS.2023.3278654","DOIUrl":null,"url":null,"abstract":"A T–S fuzzy-based \n<inline-formula> <tex-math>$H\\infty $ </tex-math></inline-formula>\n sliding mode observer (SMO)-based fault detection scheme is conducted to realize the actuator fault detection issue, including stuck fault detection and partial loss of effectiveness (PLOE) fault detection in our work. First, a T–S fuzzy attitude control model with an uncertainty term is derived from the original nonlinear hypersonic flight vehicle (HSV) model by combining local linear models at four equilibrium points. Second, the actuator fault model is introduced to further establish a T–S fuzzy HSV model with actuator faults. Then, a T–S fuzzy-based \n<inline-formula> <tex-math>$H\\infty $ </tex-math></inline-formula>\n SMO is designed for fault detection based on matrix coordinate transformation. Finally, the SMO observer simulation is conducted to the T–S fuzzy HSV model for single-input single-style actuator fault detection. The simulation results show that stuck faults can be timely and accurately detected at the fault time and the state change amplitude is approximately in direct-ratio relation with the amplitude of stuck faults, which is caused by the implicit relationship between the states and the flap. Unfortunately, the detection of PLOE faults encounters some difficulties for acceptable reasons and needs further attention and investigation.","PeriodicalId":100624,"journal":{"name":"IEEE Journal on Miniaturization for Air and Space Systems","volume":"4 3","pages":"274-282"},"PeriodicalIF":0.0000,"publicationDate":"2023-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Actuator Fault Detection of T–S Fuzzy Hypersonic Flight Vehicle Model: A T–S Fuzzy-Based H∞ Sliding Mode Observer Approach\",\"authors\":\"Meijie Liu;Ping Luo;Changhua Hu;Rui Guo;Xiaoxiang Hu\",\"doi\":\"10.1109/JMASS.2023.3278654\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A T–S fuzzy-based \\n<inline-formula> <tex-math>$H\\\\infty $ </tex-math></inline-formula>\\n sliding mode observer (SMO)-based fault detection scheme is conducted to realize the actuator fault detection issue, including stuck fault detection and partial loss of effectiveness (PLOE) fault detection in our work. First, a T–S fuzzy attitude control model with an uncertainty term is derived from the original nonlinear hypersonic flight vehicle (HSV) model by combining local linear models at four equilibrium points. Second, the actuator fault model is introduced to further establish a T–S fuzzy HSV model with actuator faults. Then, a T–S fuzzy-based \\n<inline-formula> <tex-math>$H\\\\infty $ </tex-math></inline-formula>\\n SMO is designed for fault detection based on matrix coordinate transformation. Finally, the SMO observer simulation is conducted to the T–S fuzzy HSV model for single-input single-style actuator fault detection. The simulation results show that stuck faults can be timely and accurately detected at the fault time and the state change amplitude is approximately in direct-ratio relation with the amplitude of stuck faults, which is caused by the implicit relationship between the states and the flap. Unfortunately, the detection of PLOE faults encounters some difficulties for acceptable reasons and needs further attention and investigation.\",\"PeriodicalId\":100624,\"journal\":{\"name\":\"IEEE Journal on Miniaturization for Air and Space Systems\",\"volume\":\"4 3\",\"pages\":\"274-282\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-08-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Journal on Miniaturization for Air and Space Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10226530/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Journal on Miniaturization for Air and Space Systems","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10226530/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

提出了一种基于T–S模糊的$H\infty$滑模观测器(SMO)故障检测方案来实现执行器故障检测问题,包括我们工作中的卡住故障检测和部分失效(PLOE)故障检测。首先,将四个平衡点的局部线性模型相结合,从原始的非线性高超音速飞行器(HSV)模型出发,导出了一个带有不确定性项的T–S模糊姿态控制模型。其次,引入执行器故障模型,进一步建立了执行器故障的T–S模糊HSV模型。然后,设计了一个基于T–S模糊的$H\infty$SMO,用于基于矩阵坐标变换的故障检测。最后,对T–S模糊HSV模型进行了SMO观测器仿真,用于单输入单型执行器故障检测。仿真结果表明,在故障时刻能够及时、准确地检测出卡滞故障,状态变化幅度与卡滞故障幅度近似成正比关系,这是由状态与襟翼之间的隐式关系引起的。不幸的是,由于可接受的原因,PLOE故障的检测遇到了一些困难,需要进一步关注和调查。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Actuator Fault Detection of T–S Fuzzy Hypersonic Flight Vehicle Model: A T–S Fuzzy-Based H∞ Sliding Mode Observer Approach
A T–S fuzzy-based $H\infty $ sliding mode observer (SMO)-based fault detection scheme is conducted to realize the actuator fault detection issue, including stuck fault detection and partial loss of effectiveness (PLOE) fault detection in our work. First, a T–S fuzzy attitude control model with an uncertainty term is derived from the original nonlinear hypersonic flight vehicle (HSV) model by combining local linear models at four equilibrium points. Second, the actuator fault model is introduced to further establish a T–S fuzzy HSV model with actuator faults. Then, a T–S fuzzy-based $H\infty $ SMO is designed for fault detection based on matrix coordinate transformation. Finally, the SMO observer simulation is conducted to the T–S fuzzy HSV model for single-input single-style actuator fault detection. The simulation results show that stuck faults can be timely and accurately detected at the fault time and the state change amplitude is approximately in direct-ratio relation with the amplitude of stuck faults, which is caused by the implicit relationship between the states and the flap. Unfortunately, the detection of PLOE faults encounters some difficulties for acceptable reasons and needs further attention and investigation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.40
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信