纳米颗粒透射电子显微镜图像表面应变测量的准确性

IF 3.56 Q1 Medicine
Jacob Madsen, Pei Liu, Jakob B. Wagner, Thomas W. Hansen, Jakob Schiøtz
{"title":"纳米颗粒透射电子显微镜图像表面应变测量的准确性","authors":"Jacob Madsen,&nbsp;Pei Liu,&nbsp;Jakob B. Wagner,&nbsp;Thomas W. Hansen,&nbsp;Jakob Schiøtz","doi":"10.1186/s40679-017-0047-0","DOIUrl":null,"url":null,"abstract":"<p>Strain analysis from high-resolution transmission electron microscopy (HRTEM) images offers a convenient tool for measuring strain in materials at the atomic scale. In this paper we present a theoretical study of the precision and accuracy of surface strain measurements directly from aberration-corrected HRTEM images. We examine the influence of defocus, crystal tilt and noise, and find that absolute errors of at least 1–2% strain should be expected. The model structures include surface relaxations determined using molecular dynamics, and we show that this is important for correctly evaluating the errors introduced by image aberrations.</p>","PeriodicalId":460,"journal":{"name":"Advanced Structural and Chemical Imaging","volume":null,"pages":null},"PeriodicalIF":3.5600,"publicationDate":"2017-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/s40679-017-0047-0","citationCount":"18","resultStr":"{\"title\":\"Accuracy of surface strain measurements from transmission electron microscopy images of nanoparticles\",\"authors\":\"Jacob Madsen,&nbsp;Pei Liu,&nbsp;Jakob B. Wagner,&nbsp;Thomas W. Hansen,&nbsp;Jakob Schiøtz\",\"doi\":\"10.1186/s40679-017-0047-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Strain analysis from high-resolution transmission electron microscopy (HRTEM) images offers a convenient tool for measuring strain in materials at the atomic scale. In this paper we present a theoretical study of the precision and accuracy of surface strain measurements directly from aberration-corrected HRTEM images. We examine the influence of defocus, crystal tilt and noise, and find that absolute errors of at least 1–2% strain should be expected. The model structures include surface relaxations determined using molecular dynamics, and we show that this is important for correctly evaluating the errors introduced by image aberrations.</p>\",\"PeriodicalId\":460,\"journal\":{\"name\":\"Advanced Structural and Chemical Imaging\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.5600,\"publicationDate\":\"2017-10-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1186/s40679-017-0047-0\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advanced Structural and Chemical Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://link.springer.com/article/10.1186/s40679-017-0047-0\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Structural and Chemical Imaging","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1186/s40679-017-0047-0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 18

摘要

高分辨率透射电子显微镜(HRTEM)图像的应变分析为在原子尺度上测量材料的应变提供了一种方便的工具。本文对直接从像差校正的HRTEM图像测量表面应变的精度和准确性进行了理论研究。我们研究了离焦、晶体倾斜和噪声的影响,发现至少有1-2%的应变绝对误差应该是预期的。模型结构包括使用分子动力学确定的表面弛豫,我们表明这对于正确评估由像差引入的误差是重要的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Accuracy of surface strain measurements from transmission electron microscopy images of nanoparticles

Accuracy of surface strain measurements from transmission electron microscopy images of nanoparticles

Strain analysis from high-resolution transmission electron microscopy (HRTEM) images offers a convenient tool for measuring strain in materials at the atomic scale. In this paper we present a theoretical study of the precision and accuracy of surface strain measurements directly from aberration-corrected HRTEM images. We examine the influence of defocus, crystal tilt and noise, and find that absolute errors of at least 1–2% strain should be expected. The model structures include surface relaxations determined using molecular dynamics, and we show that this is important for correctly evaluating the errors introduced by image aberrations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Advanced Structural and Chemical Imaging
Advanced Structural and Chemical Imaging Medicine-Radiology, Nuclear Medicine and Imaging
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信