三种D-二聚体检测对疑似深静脉血栓形成患者的诊断性能评估:STA Liatest D-Di-plus、Tina quant D-二聚物Gen.2和INNOVANCE D-二聚器

Q4 Medicine
Brita Tonne (Brita Tønne) , Marit Holmefjord Pedersen , Synne G. Fronas , Camilla Tovik Jorgensen (Camilla Tøvik Jørgensen) , Erik Koldberg Amundsen , Julie Berge Maehlum (Julie Berge Mæhlum) , Thea Berg , Aase-Berit Mathisen (Åse-Berit Mathisen) , Waleed Ghanima , Lamya Garabet
{"title":"三种D-二聚体检测对疑似深静脉血栓形成患者的诊断性能评估:STA Liatest D-Di-plus、Tina quant D-二聚物Gen.2和INNOVANCE D-二聚器","authors":"Brita Tonne (Brita Tønne) ,&nbsp;Marit Holmefjord Pedersen ,&nbsp;Synne G. Fronas ,&nbsp;Camilla Tovik Jorgensen (Camilla Tøvik Jørgensen) ,&nbsp;Erik Koldberg Amundsen ,&nbsp;Julie Berge Maehlum (Julie Berge Mæhlum) ,&nbsp;Thea Berg ,&nbsp;Aase-Berit Mathisen (Åse-Berit Mathisen) ,&nbsp;Waleed Ghanima ,&nbsp;Lamya Garabet","doi":"10.1016/j.tru.2023.100147","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>D-dimer is a crucial test to exclude deep vein thrombosis (DVT). We aimed to evaluate the performance of three D-dimer assays: STA-Liatest D-Di Plus (Diagnostica Stago), Tina-quant D-Dimer Gen. 2 (Roche Diagnostics), and INNOVANCE D-Dimer (Siemens Healthineers Diagnostics) in the exclusion of DVT.</p></div><div><h3>Methods</h3><p>Samples (n = 1032) and clinical data were acquired from a prospective outcome study (Rivaroxaban for Scheduled Work-up of Deep Vein Thrombosis – the Ri-Schedule study), which included patients referred to the emergency department with suspected lower-limb DVT. D-dimer was determined with STA-Liatest, and only patients with positive D-dimer values (≥0.5 μg/mL) as stand-alone, were referred for compression ultrasonography to confirm or exclude DVT. Patients were followed up 90 days after inclusion. Samples were also analyzed with Tina-quant Gen. 2, and INNOVANCE assays. The diagnostic performances of the three assays were investigated.</p></div><div><h3>Results</h3><p>Positive D-dimer (≥0.5 μg/mL) was found in 733 patients (71%) with STA-Liatest, 691 patients (67%) with Tina-quant Gen. 2, and 766 (74%) with INNOVANCE. DVT was confirmed by compression ultrasonography in 196 patients (27%) with positive D-dimer with STA-Liatest. Of those, six (3%) had negative D-dimer (&lt;0.5 μg/mL) with at least one of the three assays yielding a failure rate of 0.7% with STA-Liatest, 2% with Tina-quant Gen. 2, and 2% with INNOVANCE. The sensitivity and negative predictive value (NPV) for STA-Liatest were 99.0% (95% CI 96.4–99.9) and 99.3% (95% CI 97.4–99.8), for Tina-quant Gen. 2 97.5% (95% CI 94.1–99.2) and 98.5% (95% CI 96.6–99.4), and for INNOVANCE 98.0% (95% CI 94.9–99.0) and 98.5% (95% CI 96.1–99.4) respectively. The efficiency to exclude DVT based on D-dimer as a stand-alone test was 29% (95% CI 26–33) for STA-Liatest, 33% (95% CI 30–37) for Tina-quant Gen. 2, and 26% (95% CI 23–29) for INNOVANCE.</p></div><div><h3>Conclusion</h3><p>STA-Liatest, Tina-quant Gen. 2, and INNOVANCE showed good performances with sensitivity ≥97% and NPV ≥98%. The efficiency to exclude DVT varied and was highest for Tina-quant Gen. 2, whereas the failure rate was lowest for STA-Liatest.</p></div>","PeriodicalId":34401,"journal":{"name":"Thrombosis Update","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-08-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the diagnostic performance of three D-dimer assays in patients with suspected deep vein thrombosis: STA-Liatest D-Di plus, Tina-quant D-dimer Gen. 2, and INNOVANCE D-dimer\",\"authors\":\"Brita Tonne (Brita Tønne) ,&nbsp;Marit Holmefjord Pedersen ,&nbsp;Synne G. Fronas ,&nbsp;Camilla Tovik Jorgensen (Camilla Tøvik Jørgensen) ,&nbsp;Erik Koldberg Amundsen ,&nbsp;Julie Berge Maehlum (Julie Berge Mæhlum) ,&nbsp;Thea Berg ,&nbsp;Aase-Berit Mathisen (Åse-Berit Mathisen) ,&nbsp;Waleed Ghanima ,&nbsp;Lamya Garabet\",\"doi\":\"10.1016/j.tru.2023.100147\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><p>D-dimer is a crucial test to exclude deep vein thrombosis (DVT). We aimed to evaluate the performance of three D-dimer assays: STA-Liatest D-Di Plus (Diagnostica Stago), Tina-quant D-Dimer Gen. 2 (Roche Diagnostics), and INNOVANCE D-Dimer (Siemens Healthineers Diagnostics) in the exclusion of DVT.</p></div><div><h3>Methods</h3><p>Samples (n = 1032) and clinical data were acquired from a prospective outcome study (Rivaroxaban for Scheduled Work-up of Deep Vein Thrombosis – the Ri-Schedule study), which included patients referred to the emergency department with suspected lower-limb DVT. D-dimer was determined with STA-Liatest, and only patients with positive D-dimer values (≥0.5 μg/mL) as stand-alone, were referred for compression ultrasonography to confirm or exclude DVT. Patients were followed up 90 days after inclusion. Samples were also analyzed with Tina-quant Gen. 2, and INNOVANCE assays. The diagnostic performances of the three assays were investigated.</p></div><div><h3>Results</h3><p>Positive D-dimer (≥0.5 μg/mL) was found in 733 patients (71%) with STA-Liatest, 691 patients (67%) with Tina-quant Gen. 2, and 766 (74%) with INNOVANCE. DVT was confirmed by compression ultrasonography in 196 patients (27%) with positive D-dimer with STA-Liatest. Of those, six (3%) had negative D-dimer (&lt;0.5 μg/mL) with at least one of the three assays yielding a failure rate of 0.7% with STA-Liatest, 2% with Tina-quant Gen. 2, and 2% with INNOVANCE. The sensitivity and negative predictive value (NPV) for STA-Liatest were 99.0% (95% CI 96.4–99.9) and 99.3% (95% CI 97.4–99.8), for Tina-quant Gen. 2 97.5% (95% CI 94.1–99.2) and 98.5% (95% CI 96.6–99.4), and for INNOVANCE 98.0% (95% CI 94.9–99.0) and 98.5% (95% CI 96.1–99.4) respectively. The efficiency to exclude DVT based on D-dimer as a stand-alone test was 29% (95% CI 26–33) for STA-Liatest, 33% (95% CI 30–37) for Tina-quant Gen. 2, and 26% (95% CI 23–29) for INNOVANCE.</p></div><div><h3>Conclusion</h3><p>STA-Liatest, Tina-quant Gen. 2, and INNOVANCE showed good performances with sensitivity ≥97% and NPV ≥98%. The efficiency to exclude DVT varied and was highest for Tina-quant Gen. 2, whereas the failure rate was lowest for STA-Liatest.</p></div>\",\"PeriodicalId\":34401,\"journal\":{\"name\":\"Thrombosis Update\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-08-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Thrombosis Update\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666572723000184\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Thrombosis Update","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666572723000184","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

引言D二聚体是排除深静脉血栓形成(DVT)的关键测试。我们旨在评估三种D-二聚体测定的性能:STA Liatest D-Di Plus(Diagnostica Stago)、Tina quant D-dimer Gen.2(Roche Diagnostics)、,和INNOVANCE D-二聚体(西门子Healthineers Diagnostics)排除DVT。方法从一项前瞻性结果研究(利伐沙班用于深静脉血栓形成的计划治疗-Ri计划研究)中获得样本(n=1032)和临床数据,该研究包括疑似下肢DVT的急诊患者。用STA Liatest测定D-二聚体,只有D-二聚物值阳性(≥0.5μg/mL)的患者单独接受压缩超声检查以确认或排除DVT。患者在入选后90天进行随访。样品还用Tina quant Gen.2和INNOVANCE分析法进行了分析。研究了三种检测方法的诊断性能。结果STA阳性733例(71%),Tina quant Gen.2阳性691例(67%),INNOVANCE阳性766例(74%)。196例(27%)STA-Liatest阳性D-二聚体患者经压缩超声证实DVT。其中,6例(3%)D-二聚体呈阴性(<0.5μg/mL),三种检测中至少有一种STA Liatest的失败率为0.7%,Tina quant Gen.2的失败率是2%,INNOVANCE的失败率则是2%。STA Liatest的敏感性和阴性预测值(NPV)分别为99.0%(95%CI 96.4-99.9)和99.3%(95%CI 97.4-99.8。将基于D-二聚体的DVT作为一项独立测试排除在外的效率,STA-Liatest为29%(95%CI 26-33),Tina quant Gen.2为33%(95%CI 30-37),INNOVANCE为26%(95%CI 23-29)。排除DVT的效率各不相同,Tina quant Gen.2的效率最高,而STA Liatest的失败率最低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of the diagnostic performance of three D-dimer assays in patients with suspected deep vein thrombosis: STA-Liatest D-Di plus, Tina-quant D-dimer Gen. 2, and INNOVANCE D-dimer

Introduction

D-dimer is a crucial test to exclude deep vein thrombosis (DVT). We aimed to evaluate the performance of three D-dimer assays: STA-Liatest D-Di Plus (Diagnostica Stago), Tina-quant D-Dimer Gen. 2 (Roche Diagnostics), and INNOVANCE D-Dimer (Siemens Healthineers Diagnostics) in the exclusion of DVT.

Methods

Samples (n = 1032) and clinical data were acquired from a prospective outcome study (Rivaroxaban for Scheduled Work-up of Deep Vein Thrombosis – the Ri-Schedule study), which included patients referred to the emergency department with suspected lower-limb DVT. D-dimer was determined with STA-Liatest, and only patients with positive D-dimer values (≥0.5 μg/mL) as stand-alone, were referred for compression ultrasonography to confirm or exclude DVT. Patients were followed up 90 days after inclusion. Samples were also analyzed with Tina-quant Gen. 2, and INNOVANCE assays. The diagnostic performances of the three assays were investigated.

Results

Positive D-dimer (≥0.5 μg/mL) was found in 733 patients (71%) with STA-Liatest, 691 patients (67%) with Tina-quant Gen. 2, and 766 (74%) with INNOVANCE. DVT was confirmed by compression ultrasonography in 196 patients (27%) with positive D-dimer with STA-Liatest. Of those, six (3%) had negative D-dimer (<0.5 μg/mL) with at least one of the three assays yielding a failure rate of 0.7% with STA-Liatest, 2% with Tina-quant Gen. 2, and 2% with INNOVANCE. The sensitivity and negative predictive value (NPV) for STA-Liatest were 99.0% (95% CI 96.4–99.9) and 99.3% (95% CI 97.4–99.8), for Tina-quant Gen. 2 97.5% (95% CI 94.1–99.2) and 98.5% (95% CI 96.6–99.4), and for INNOVANCE 98.0% (95% CI 94.9–99.0) and 98.5% (95% CI 96.1–99.4) respectively. The efficiency to exclude DVT based on D-dimer as a stand-alone test was 29% (95% CI 26–33) for STA-Liatest, 33% (95% CI 30–37) for Tina-quant Gen. 2, and 26% (95% CI 23–29) for INNOVANCE.

Conclusion

STA-Liatest, Tina-quant Gen. 2, and INNOVANCE showed good performances with sensitivity ≥97% and NPV ≥98%. The efficiency to exclude DVT varied and was highest for Tina-quant Gen. 2, whereas the failure rate was lowest for STA-Liatest.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Thrombosis Update
Thrombosis Update Medicine-Hematology
CiteScore
1.90
自引率
0.00%
发文量
33
审稿时长
86 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信