{"title":"两种新的立体定向放射治疗方法,用于局部晚期、既往放疗过的头颈癌患者。","authors":"Damodar Pokhrel PhD, Josh Misa BS, Shane McCarthy MS, Eddy S. Yang MD, PhD","doi":"10.1016/j.meddos.2023.09.003","DOIUrl":null,"url":null,"abstract":"<div><p><span>To determine the feasibility and utility of conebeam CT-guided stereotactic radiotherapy<span><span> for locally recurrent, previously irradiated head and neck cancer<span> (HNC) patients on the Halcyon, a ring delivery system (RDS). This research aims to quantify plan quality, treatment delivery accuracy, and overall efficacy by comparing against novel clinical </span></span>TrueBeam<span><span> HyperArc method. Ten recurrent HNC patients who were treated at our institution on TrueBeam (6MV-FFF) for 30 to 40 Gy in 3 to 5 fractions with noncoplanar HyperArc plans were re-planned on Halcyon (6MV-FFF). These plans were re-planned with the same Acuros-based dose engine. Additionally, we used site-specific full/partial coplanar VMAT arcs. PTV coverage, mean dose to </span>GTV<span>, maximum dose to organs-at-risk (OAR), beam-on time (BOT), and quality assurance (QA) results were investigated and compared. Halcyon provided highly conformal HNC SRT plans with slightly superior mean PTVD99 coverage (96.7% </span></span></span></span><em>vs</em> 95.5%, <em>p</em> = 0.071), and slightly lower mean GTV dose (37.8 Gy <em>vs</em> 38.2 Gy, <em>p</em> = 0.241) when compared to the HyperArc plans. Differences in plan conformality and maximum dose to OARs were statistically insignificant. Due to Halcyon's coplanar geometry, D2cm was significantly higher (<em>p</em> = 0.001) but Halcyon did result in a reduced normal brain dose by 1 Gy on average and up to 5.2 Gy in some cases. Halcyon provided similar patient-specific QA pass rates with a 2%/2mm gamma criteria (98.2% <em>vs</em> 98.5%) and independent in-house Monte Carlo second check results (97.7% <em>vs</em> 98.2%), suggesting identical treatment delivery accuracy. Halcyon plans resulted in slightly longer beam-on time (3.16 vs 2.30 minutes, <em>p</em> = 0.010), however door-to-door patient time is expected to be <10 minutes. Compared to clinical TrueBeam HyperArc, Halcyon SRT plans provided similar plan quality and treatment delivery accuracy with a potentially faster overall treatment using fully automated patient setup and verification. Rapid delivery of recurrent HNC SRT may reduce intrafraction motion errors while also improving patient compliance and comfort. To provide high-quality of HNC SRT similar to HyperArc, we recommend Halcyon users consider commissioning this novel method. This method will be useful for remote and underserved patient cohorts including Halcyon-only clinics as well.</p></div>","PeriodicalId":49837,"journal":{"name":"Medical Dosimetry","volume":"49 2","pages":"Pages 114-120"},"PeriodicalIF":1.1000,"publicationDate":"2023-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Two novel stereotactic radiotherapy methods for locally advanced, previously irradiated head and neck cancers patients\",\"authors\":\"Damodar Pokhrel PhD, Josh Misa BS, Shane McCarthy MS, Eddy S. Yang MD, PhD\",\"doi\":\"10.1016/j.meddos.2023.09.003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p><span>To determine the feasibility and utility of conebeam CT-guided stereotactic radiotherapy<span><span> for locally recurrent, previously irradiated head and neck cancer<span> (HNC) patients on the Halcyon, a ring delivery system (RDS). This research aims to quantify plan quality, treatment delivery accuracy, and overall efficacy by comparing against novel clinical </span></span>TrueBeam<span><span> HyperArc method. Ten recurrent HNC patients who were treated at our institution on TrueBeam (6MV-FFF) for 30 to 40 Gy in 3 to 5 fractions with noncoplanar HyperArc plans were re-planned on Halcyon (6MV-FFF). These plans were re-planned with the same Acuros-based dose engine. Additionally, we used site-specific full/partial coplanar VMAT arcs. PTV coverage, mean dose to </span>GTV<span>, maximum dose to organs-at-risk (OAR), beam-on time (BOT), and quality assurance (QA) results were investigated and compared. Halcyon provided highly conformal HNC SRT plans with slightly superior mean PTVD99 coverage (96.7% </span></span></span></span><em>vs</em> 95.5%, <em>p</em> = 0.071), and slightly lower mean GTV dose (37.8 Gy <em>vs</em> 38.2 Gy, <em>p</em> = 0.241) when compared to the HyperArc plans. Differences in plan conformality and maximum dose to OARs were statistically insignificant. Due to Halcyon's coplanar geometry, D2cm was significantly higher (<em>p</em> = 0.001) but Halcyon did result in a reduced normal brain dose by 1 Gy on average and up to 5.2 Gy in some cases. Halcyon provided similar patient-specific QA pass rates with a 2%/2mm gamma criteria (98.2% <em>vs</em> 98.5%) and independent in-house Monte Carlo second check results (97.7% <em>vs</em> 98.2%), suggesting identical treatment delivery accuracy. Halcyon plans resulted in slightly longer beam-on time (3.16 vs 2.30 minutes, <em>p</em> = 0.010), however door-to-door patient time is expected to be <10 minutes. Compared to clinical TrueBeam HyperArc, Halcyon SRT plans provided similar plan quality and treatment delivery accuracy with a potentially faster overall treatment using fully automated patient setup and verification. Rapid delivery of recurrent HNC SRT may reduce intrafraction motion errors while also improving patient compliance and comfort. To provide high-quality of HNC SRT similar to HyperArc, we recommend Halcyon users consider commissioning this novel method. This method will be useful for remote and underserved patient cohorts including Halcyon-only clinics as well.</p></div>\",\"PeriodicalId\":49837,\"journal\":{\"name\":\"Medical Dosimetry\",\"volume\":\"49 2\",\"pages\":\"Pages 114-120\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-10-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medical Dosimetry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0958394723000791\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ONCOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Dosimetry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0958394723000791","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ONCOLOGY","Score":null,"Total":0}
Two novel stereotactic radiotherapy methods for locally advanced, previously irradiated head and neck cancers patients
To determine the feasibility and utility of conebeam CT-guided stereotactic radiotherapy for locally recurrent, previously irradiated head and neck cancer (HNC) patients on the Halcyon, a ring delivery system (RDS). This research aims to quantify plan quality, treatment delivery accuracy, and overall efficacy by comparing against novel clinical TrueBeam HyperArc method. Ten recurrent HNC patients who were treated at our institution on TrueBeam (6MV-FFF) for 30 to 40 Gy in 3 to 5 fractions with noncoplanar HyperArc plans were re-planned on Halcyon (6MV-FFF). These plans were re-planned with the same Acuros-based dose engine. Additionally, we used site-specific full/partial coplanar VMAT arcs. PTV coverage, mean dose to GTV, maximum dose to organs-at-risk (OAR), beam-on time (BOT), and quality assurance (QA) results were investigated and compared. Halcyon provided highly conformal HNC SRT plans with slightly superior mean PTVD99 coverage (96.7% vs 95.5%, p = 0.071), and slightly lower mean GTV dose (37.8 Gy vs 38.2 Gy, p = 0.241) when compared to the HyperArc plans. Differences in plan conformality and maximum dose to OARs were statistically insignificant. Due to Halcyon's coplanar geometry, D2cm was significantly higher (p = 0.001) but Halcyon did result in a reduced normal brain dose by 1 Gy on average and up to 5.2 Gy in some cases. Halcyon provided similar patient-specific QA pass rates with a 2%/2mm gamma criteria (98.2% vs 98.5%) and independent in-house Monte Carlo second check results (97.7% vs 98.2%), suggesting identical treatment delivery accuracy. Halcyon plans resulted in slightly longer beam-on time (3.16 vs 2.30 minutes, p = 0.010), however door-to-door patient time is expected to be <10 minutes. Compared to clinical TrueBeam HyperArc, Halcyon SRT plans provided similar plan quality and treatment delivery accuracy with a potentially faster overall treatment using fully automated patient setup and verification. Rapid delivery of recurrent HNC SRT may reduce intrafraction motion errors while also improving patient compliance and comfort. To provide high-quality of HNC SRT similar to HyperArc, we recommend Halcyon users consider commissioning this novel method. This method will be useful for remote and underserved patient cohorts including Halcyon-only clinics as well.
期刊介绍:
Medical Dosimetry, the official journal of the American Association of Medical Dosimetrists, is the key source of information on new developments for the medical dosimetrist. Practical and comprehensive in coverage, the journal features original contributions and review articles by medical dosimetrists, oncologists, physicists, and radiation therapy technologists on clinical applications and techniques of external beam, interstitial, intracavitary and intraluminal irradiation in cancer management. Articles dealing primarily with physics will be reviewed by a specially appointed team of experts in the field.