{"title":"一种四端轴双屏蔽网络","authors":"O. Mikhal","doi":"10.15407/techned2022.06.077","DOIUrl":null,"url":null,"abstract":"An impedance measurement object with an H-shaped four-terminal equivalent substitution circuit is considered. An error analysis was performed for sensors whose non-informative supply resistances are of the same order or exceed the measured impedance. A new definition of four-terminal impedance has been proposed, namely four-terminal axial be-shielded (FTABS) measuring object. Based on such new definition, the scheme of axial-bishielded bridges is proposed for precision measurement of temperature and electrolytic conductivity of liquids. Such bridges differ from the well-known coaxial bridges since the former ones have an additional circuit for equipotential protection, which is located between the flow circuits of direct and reverse currents. References 18, figures 7.","PeriodicalId":38557,"journal":{"name":"Technical Electrodynamics","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-10-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A FOUR TERMINAL AXIAL-BISHIELDED NETWORKS\",\"authors\":\"O. Mikhal\",\"doi\":\"10.15407/techned2022.06.077\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An impedance measurement object with an H-shaped four-terminal equivalent substitution circuit is considered. An error analysis was performed for sensors whose non-informative supply resistances are of the same order or exceed the measured impedance. A new definition of four-terminal impedance has been proposed, namely four-terminal axial be-shielded (FTABS) measuring object. Based on such new definition, the scheme of axial-bishielded bridges is proposed for precision measurement of temperature and electrolytic conductivity of liquids. Such bridges differ from the well-known coaxial bridges since the former ones have an additional circuit for equipotential protection, which is located between the flow circuits of direct and reverse currents. References 18, figures 7.\",\"PeriodicalId\":38557,\"journal\":{\"name\":\"Technical Electrodynamics\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Technical Electrodynamics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15407/techned2022.06.077\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Energy\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technical Electrodynamics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15407/techned2022.06.077","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Energy","Score":null,"Total":0}
An impedance measurement object with an H-shaped four-terminal equivalent substitution circuit is considered. An error analysis was performed for sensors whose non-informative supply resistances are of the same order or exceed the measured impedance. A new definition of four-terminal impedance has been proposed, namely four-terminal axial be-shielded (FTABS) measuring object. Based on such new definition, the scheme of axial-bishielded bridges is proposed for precision measurement of temperature and electrolytic conductivity of liquids. Such bridges differ from the well-known coaxial bridges since the former ones have an additional circuit for equipotential protection, which is located between the flow circuits of direct and reverse currents. References 18, figures 7.