{"title":"酮症酸中毒导致血液丙酮浓度升高的个体对Intoxyzer®8000C的“干扰检测”","authors":"H. Wallage, I. Bugyra","doi":"10.1080/00085030.2017.1328162","DOIUrl":null,"url":null,"abstract":"ABSTRACT A 72-year-old male was arrested for impaired driving. He had a history of chronic alcohol1 consumption and limited food intake on the day of his arrest. The Intoxilyzer® 8000C provided the following communication messages during testing: “Interferent Detect”, “Invalid Sample” and then an additional “Interferent Detect.” This information from the Intoxilyzer® 8000C prompted a medical investigation. The individual was taken to the hospital where ketoacidosis was part of the medical diagnosis. Blood samples were collected and analyzed at two hospital laboratories and the Centre of Forensic Sciences. The results from the hospital analyses were serum ethanol concentrations of 172 and 161 mg/100 mL and an acetone concentration of 18 mg/100 mL; the results from the forensic analyses were blood ethanol, acetone, isopropanol and beta-hydroxybutyrate concentrations of 139 mg/100 mL, 21 mg/100 mL, <5 mg/100 mL and 468 mg/L, respectively.","PeriodicalId":44383,"journal":{"name":"Canadian Society of Forensic Science Journal","volume":"50 1","pages":"157 - 163"},"PeriodicalIF":0.2000,"publicationDate":"2017-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/00085030.2017.1328162","citationCount":"0","resultStr":"{\"title\":\"“Interferent Detect” on the Intoxilyzer® 8000C in an individual with an elevated blood acetone concentration due to ketoacidosis\",\"authors\":\"H. Wallage, I. Bugyra\",\"doi\":\"10.1080/00085030.2017.1328162\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT A 72-year-old male was arrested for impaired driving. He had a history of chronic alcohol1 consumption and limited food intake on the day of his arrest. The Intoxilyzer® 8000C provided the following communication messages during testing: “Interferent Detect”, “Invalid Sample” and then an additional “Interferent Detect.” This information from the Intoxilyzer® 8000C prompted a medical investigation. The individual was taken to the hospital where ketoacidosis was part of the medical diagnosis. Blood samples were collected and analyzed at two hospital laboratories and the Centre of Forensic Sciences. The results from the hospital analyses were serum ethanol concentrations of 172 and 161 mg/100 mL and an acetone concentration of 18 mg/100 mL; the results from the forensic analyses were blood ethanol, acetone, isopropanol and beta-hydroxybutyrate concentrations of 139 mg/100 mL, 21 mg/100 mL, <5 mg/100 mL and 468 mg/L, respectively.\",\"PeriodicalId\":44383,\"journal\":{\"name\":\"Canadian Society of Forensic Science Journal\",\"volume\":\"50 1\",\"pages\":\"157 - 163\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2017-05-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/00085030.2017.1328162\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Canadian Society of Forensic Science Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/00085030.2017.1328162\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, LEGAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian Society of Forensic Science Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/00085030.2017.1328162","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, LEGAL","Score":null,"Total":0}
引用次数: 0

摘要

摘要:一名72岁男性因驾驶障碍被捕。他有长期饮酒史,被捕当天食物摄入有限。Intoxilyzer®8000C在测试过程中提供了以下通信信息:“干扰检测”、“无效样本”,然后是一个额外的“干扰检测。”来自Intoxily®8000C的这些信息促使进行医学调查。患者被送往医院,酮症酸中毒是医学诊断的一部分。在两个医院实验室和法医科学中心采集并分析了血样。医院分析的结果是血清乙醇浓度为172和161毫克/100毫升,丙酮浓度为18毫克/100毫升;法医分析结果显示,血液中乙醇、丙酮、异丙醇和β-羟基丁酸的浓度分别为139 mg/100 mL、21 mg/100 mL,<5 mg/100 mL和468 mg/L。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
“Interferent Detect” on the Intoxilyzer® 8000C in an individual with an elevated blood acetone concentration due to ketoacidosis
ABSTRACT A 72-year-old male was arrested for impaired driving. He had a history of chronic alcohol1 consumption and limited food intake on the day of his arrest. The Intoxilyzer® 8000C provided the following communication messages during testing: “Interferent Detect”, “Invalid Sample” and then an additional “Interferent Detect.” This information from the Intoxilyzer® 8000C prompted a medical investigation. The individual was taken to the hospital where ketoacidosis was part of the medical diagnosis. Blood samples were collected and analyzed at two hospital laboratories and the Centre of Forensic Sciences. The results from the hospital analyses were serum ethanol concentrations of 172 and 161 mg/100 mL and an acetone concentration of 18 mg/100 mL; the results from the forensic analyses were blood ethanol, acetone, isopropanol and beta-hydroxybutyrate concentrations of 139 mg/100 mL, 21 mg/100 mL, <5 mg/100 mL and 468 mg/L, respectively.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.00
自引率
0.00%
发文量
21
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信