6K极低温拉伸试验:Fe-Mn-Cr钢的组织和力学性能

IF 1.1 4区 材料科学 Q4 MATERIALS SCIENCE, MULTIDISCIPLINARY
Young-Kyun Kim, K. Lim, Y. Na
{"title":"6K极低温拉伸试验:Fe-Mn-Cr钢的组织和力学性能","authors":"Young-Kyun Kim, K. Lim, Y. Na","doi":"10.3365/kjmm.2023.61.6.389","DOIUrl":null,"url":null,"abstract":"Materials with superior cryogenic strength and good ductility are increasingly in demand for resident friendly liquid-hydrogen (20K) storage tanks. Additionally, the space industry also requires materials that retain excellent mechanical properties at extremely low temperatures. However, mechanical testing at such low temperatures is highly limited due to the difficulties in achieving and maintaining such conditions, while also providing adequate thermal insulation to prevent heat transfer from the surrounding environment. In this study, we present a novel tensile testing technique for a Fe-15Mn-13Cr-3Si-3Ni-0.1C (wt.%) steel at the temperature of liquid helium. To minimize the use of expensive liquid helium, we adopted a method of injecting liquid helium vapor and set the temperature for tensile testing at 6 K. The present alloy has a single face-centered cubic (FCC) structure with a large amount of stacking faults after annealing treatment. The Fe-Mn-Cr steel exhibited a superior ultimate tensile strength of 1200 MPa and good ductility of 35% at 6K. Moreover, compared with room temperature tensile tests, discontinuous plastic flow, i.e. serrated flow, occurred at extremely low temperature.","PeriodicalId":17894,"journal":{"name":"Korean Journal of Metals and Materials","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2023-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Tensile testing at the Extremely Low Temperature of 6K : Microstructure and Mechanical Properties of a Fe-Mn-Cr Steel\",\"authors\":\"Young-Kyun Kim, K. Lim, Y. Na\",\"doi\":\"10.3365/kjmm.2023.61.6.389\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Materials with superior cryogenic strength and good ductility are increasingly in demand for resident friendly liquid-hydrogen (20K) storage tanks. Additionally, the space industry also requires materials that retain excellent mechanical properties at extremely low temperatures. However, mechanical testing at such low temperatures is highly limited due to the difficulties in achieving and maintaining such conditions, while also providing adequate thermal insulation to prevent heat transfer from the surrounding environment. In this study, we present a novel tensile testing technique for a Fe-15Mn-13Cr-3Si-3Ni-0.1C (wt.%) steel at the temperature of liquid helium. To minimize the use of expensive liquid helium, we adopted a method of injecting liquid helium vapor and set the temperature for tensile testing at 6 K. The present alloy has a single face-centered cubic (FCC) structure with a large amount of stacking faults after annealing treatment. The Fe-Mn-Cr steel exhibited a superior ultimate tensile strength of 1200 MPa and good ductility of 35% at 6K. Moreover, compared with room temperature tensile tests, discontinuous plastic flow, i.e. serrated flow, occurred at extremely low temperature.\",\"PeriodicalId\":17894,\"journal\":{\"name\":\"Korean Journal of Metals and Materials\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-06-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Korean Journal of Metals and Materials\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://doi.org/10.3365/kjmm.2023.61.6.389\",\"RegionNum\":4,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MATERIALS SCIENCE, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Metals and Materials","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.3365/kjmm.2023.61.6.389","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

具有优异低温强度和良好延展性的材料越来越多地被用于居民友好型液氢(20K)储罐。此外,航天工业还需要在极低温度下保持优异机械性能的材料。然而,在如此低的温度下进行机械测试是非常有限的,这是由于难以实现和保持这样的条件,同时还提供足够的隔热以防止热量从周围环境传递。在本研究中,我们提出了一种新的Fe-15Mn-13Cr-3Si-3Ni-0.1C(wt.%)钢在液氦温度下的拉伸试验技术。为了最大限度地减少昂贵的液氦的使用,我们采用了注入液氦蒸汽的方法,并将拉伸测试的温度设定为6 K。本合金在退火处理后具有单面心立方(FCC)结构,具有大量的层错。Fe-Mn-Cr钢在6K下表现出1200MPa的优异极限抗拉强度和35%的良好延展性。此外,与室温拉伸试验相比,在极低的温度下发生了不连续的塑性流动,即锯齿状流动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Tensile testing at the Extremely Low Temperature of 6K : Microstructure and Mechanical Properties of a Fe-Mn-Cr Steel
Materials with superior cryogenic strength and good ductility are increasingly in demand for resident friendly liquid-hydrogen (20K) storage tanks. Additionally, the space industry also requires materials that retain excellent mechanical properties at extremely low temperatures. However, mechanical testing at such low temperatures is highly limited due to the difficulties in achieving and maintaining such conditions, while also providing adequate thermal insulation to prevent heat transfer from the surrounding environment. In this study, we present a novel tensile testing technique for a Fe-15Mn-13Cr-3Si-3Ni-0.1C (wt.%) steel at the temperature of liquid helium. To minimize the use of expensive liquid helium, we adopted a method of injecting liquid helium vapor and set the temperature for tensile testing at 6 K. The present alloy has a single face-centered cubic (FCC) structure with a large amount of stacking faults after annealing treatment. The Fe-Mn-Cr steel exhibited a superior ultimate tensile strength of 1200 MPa and good ductility of 35% at 6K. Moreover, compared with room temperature tensile tests, discontinuous plastic flow, i.e. serrated flow, occurred at extremely low temperature.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Korean Journal of Metals and Materials
Korean Journal of Metals and Materials MATERIALS SCIENCE, MULTIDISCIPLINARY-METALLURGY & METALLURGICAL ENGINEERING
CiteScore
1.80
自引率
58.30%
发文量
100
审稿时长
4-8 weeks
期刊介绍: The Korean Journal of Metals and Materials is a representative Korean-language journal of the Korean Institute of Metals and Materials (KIM); it publishes domestic and foreign academic papers related to metals and materials, in abroad range of fields from metals and materials to nano-materials, biomaterials, functional materials, energy materials, and new materials, and its official ISO designation is Korean J. Met. Mater.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信