S. Herenda, V. Asanović, E. Hasković, Dragan Radonjic, J. Scepanovic
{"title":"改性Cu-Zn-Al生物合金的体外生物医学腐蚀及酶活性抑制","authors":"S. Herenda, V. Asanović, E. Hasković, Dragan Radonjic, J. Scepanovic","doi":"10.1515/corrrev-2022-0025","DOIUrl":null,"url":null,"abstract":"Abstract The amperometric biosensor was created using a flat sheet of the Cu-Zn-Al shape memory alloy, with a shiny surface and uniform thickness below 1 mm. The high biocompatibility and a large specific surface area for enzyme loading are evaluated. In vitro biomedical corrosion testing of samples revealed successful immobilization of catalase, which has undergone quasi-reversible electron transfer from the surface and saline solution. A catalase that had been immobilized retained its basic structure and bioactivity and demonstrated a remarkable electrocatalytic response to hydrogen peroxide reduction. The reduction of hydrogen peroxide on the catalase-modified Cu-25.38Zn-3.3Al alloy was investigated using hydrodynamic amperometry in both the absence and presence of l-cysteine and K2[B3O3F4OH] inhibitors. Catalytic reduction currents have increased as a result of the gradual increase in hydrogen peroxide concentration. The study on enzyme activity inhibition has shown a lower corrosion rate of catalase-modified bioalloy than the initial sample because inhibitor ions occupy all sites of the immobilized enzyme.","PeriodicalId":10721,"journal":{"name":"Corrosion Reviews","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2023-04-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In vitro biomedical corrosion and enzyme activity inhibition on modified Cu-Zn-Al bioalloy\",\"authors\":\"S. Herenda, V. Asanović, E. Hasković, Dragan Radonjic, J. Scepanovic\",\"doi\":\"10.1515/corrrev-2022-0025\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The amperometric biosensor was created using a flat sheet of the Cu-Zn-Al shape memory alloy, with a shiny surface and uniform thickness below 1 mm. The high biocompatibility and a large specific surface area for enzyme loading are evaluated. In vitro biomedical corrosion testing of samples revealed successful immobilization of catalase, which has undergone quasi-reversible electron transfer from the surface and saline solution. A catalase that had been immobilized retained its basic structure and bioactivity and demonstrated a remarkable electrocatalytic response to hydrogen peroxide reduction. The reduction of hydrogen peroxide on the catalase-modified Cu-25.38Zn-3.3Al alloy was investigated using hydrodynamic amperometry in both the absence and presence of l-cysteine and K2[B3O3F4OH] inhibitors. Catalytic reduction currents have increased as a result of the gradual increase in hydrogen peroxide concentration. The study on enzyme activity inhibition has shown a lower corrosion rate of catalase-modified bioalloy than the initial sample because inhibitor ions occupy all sites of the immobilized enzyme.\",\"PeriodicalId\":10721,\"journal\":{\"name\":\"Corrosion Reviews\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2023-04-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Corrosion Reviews\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://doi.org/10.1515/corrrev-2022-0025\",\"RegionNum\":4,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ELECTROCHEMISTRY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Corrosion Reviews","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1515/corrrev-2022-0025","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ELECTROCHEMISTRY","Score":null,"Total":0}
In vitro biomedical corrosion and enzyme activity inhibition on modified Cu-Zn-Al bioalloy
Abstract The amperometric biosensor was created using a flat sheet of the Cu-Zn-Al shape memory alloy, with a shiny surface and uniform thickness below 1 mm. The high biocompatibility and a large specific surface area for enzyme loading are evaluated. In vitro biomedical corrosion testing of samples revealed successful immobilization of catalase, which has undergone quasi-reversible electron transfer from the surface and saline solution. A catalase that had been immobilized retained its basic structure and bioactivity and demonstrated a remarkable electrocatalytic response to hydrogen peroxide reduction. The reduction of hydrogen peroxide on the catalase-modified Cu-25.38Zn-3.3Al alloy was investigated using hydrodynamic amperometry in both the absence and presence of l-cysteine and K2[B3O3F4OH] inhibitors. Catalytic reduction currents have increased as a result of the gradual increase in hydrogen peroxide concentration. The study on enzyme activity inhibition has shown a lower corrosion rate of catalase-modified bioalloy than the initial sample because inhibitor ions occupy all sites of the immobilized enzyme.
期刊介绍:
Corrosion Reviews is an international bimonthly journal devoted to critical reviews and, to a lesser extent, outstanding original articles that are key to advancing the understanding and application of corrosion science and engineering in the service of society. Papers may be of a theoretical, experimental or practical nature, provided that they make a significant contribution to knowledge in the field.