改性Cu-Zn-Al生物合金的体外生物医学腐蚀及酶活性抑制

IF 2.7 4区 材料科学 Q3 ELECTROCHEMISTRY
S. Herenda, V. Asanović, E. Hasković, Dragan Radonjic, J. Scepanovic
{"title":"改性Cu-Zn-Al生物合金的体外生物医学腐蚀及酶活性抑制","authors":"S. Herenda, V. Asanović, E. Hasković, Dragan Radonjic, J. Scepanovic","doi":"10.1515/corrrev-2022-0025","DOIUrl":null,"url":null,"abstract":"Abstract The amperometric biosensor was created using a flat sheet of the Cu-Zn-Al shape memory alloy, with a shiny surface and uniform thickness below 1 mm. The high biocompatibility and a large specific surface area for enzyme loading are evaluated. In vitro biomedical corrosion testing of samples revealed successful immobilization of catalase, which has undergone quasi-reversible electron transfer from the surface and saline solution. A catalase that had been immobilized retained its basic structure and bioactivity and demonstrated a remarkable electrocatalytic response to hydrogen peroxide reduction. The reduction of hydrogen peroxide on the catalase-modified Cu-25.38Zn-3.3Al alloy was investigated using hydrodynamic amperometry in both the absence and presence of l-cysteine and K2[B3O3F4OH] inhibitors. Catalytic reduction currents have increased as a result of the gradual increase in hydrogen peroxide concentration. The study on enzyme activity inhibition has shown a lower corrosion rate of catalase-modified bioalloy than the initial sample because inhibitor ions occupy all sites of the immobilized enzyme.","PeriodicalId":10721,"journal":{"name":"Corrosion Reviews","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2023-04-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In vitro biomedical corrosion and enzyme activity inhibition on modified Cu-Zn-Al bioalloy\",\"authors\":\"S. Herenda, V. Asanović, E. Hasković, Dragan Radonjic, J. Scepanovic\",\"doi\":\"10.1515/corrrev-2022-0025\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The amperometric biosensor was created using a flat sheet of the Cu-Zn-Al shape memory alloy, with a shiny surface and uniform thickness below 1 mm. The high biocompatibility and a large specific surface area for enzyme loading are evaluated. In vitro biomedical corrosion testing of samples revealed successful immobilization of catalase, which has undergone quasi-reversible electron transfer from the surface and saline solution. A catalase that had been immobilized retained its basic structure and bioactivity and demonstrated a remarkable electrocatalytic response to hydrogen peroxide reduction. The reduction of hydrogen peroxide on the catalase-modified Cu-25.38Zn-3.3Al alloy was investigated using hydrodynamic amperometry in both the absence and presence of l-cysteine and K2[B3O3F4OH] inhibitors. Catalytic reduction currents have increased as a result of the gradual increase in hydrogen peroxide concentration. The study on enzyme activity inhibition has shown a lower corrosion rate of catalase-modified bioalloy than the initial sample because inhibitor ions occupy all sites of the immobilized enzyme.\",\"PeriodicalId\":10721,\"journal\":{\"name\":\"Corrosion Reviews\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2023-04-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Corrosion Reviews\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://doi.org/10.1515/corrrev-2022-0025\",\"RegionNum\":4,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ELECTROCHEMISTRY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Corrosion Reviews","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1515/corrrev-2022-0025","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ELECTROCHEMISTRY","Score":null,"Total":0}
引用次数: 0

摘要

摘要用Cu-Zn-Al形状记忆合金平板制作了一种电流型生物传感器,表面光滑,厚度均匀,小于1mm。该生物传感器具有较高的生物相容性和较大的酶负载比表面积。样品的体外生物医学腐蚀测试表明,过氧化氢酶已成功固定化,从表面和盐水溶液中进行了准可逆的电子转移。固定化的过氧化氢酶保留了其基本结构和生物活性,并对过氧化氢还原表现出显著的电催化反应。在不存在和存在l-半胱氨酸和K2[B3O3F4OH]抑制剂的情况下,使用流体动力学安培法研究了过氧化氢酶修饰的Cu-25.38Zn-3.3Al合金上过氧化氢的还原。催化还原电流由于过氧化氢浓度的逐渐增加而增加。对酶活性抑制的研究表明,过氧化氢酶修饰的生物合金的腐蚀速率低于初始样品,因为抑制剂离子占据了固定化酶的所有位点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
In vitro biomedical corrosion and enzyme activity inhibition on modified Cu-Zn-Al bioalloy
Abstract The amperometric biosensor was created using a flat sheet of the Cu-Zn-Al shape memory alloy, with a shiny surface and uniform thickness below 1 mm. The high biocompatibility and a large specific surface area for enzyme loading are evaluated. In vitro biomedical corrosion testing of samples revealed successful immobilization of catalase, which has undergone quasi-reversible electron transfer from the surface and saline solution. A catalase that had been immobilized retained its basic structure and bioactivity and demonstrated a remarkable electrocatalytic response to hydrogen peroxide reduction. The reduction of hydrogen peroxide on the catalase-modified Cu-25.38Zn-3.3Al alloy was investigated using hydrodynamic amperometry in both the absence and presence of l-cysteine and K2[B3O3F4OH] inhibitors. Catalytic reduction currents have increased as a result of the gradual increase in hydrogen peroxide concentration. The study on enzyme activity inhibition has shown a lower corrosion rate of catalase-modified bioalloy than the initial sample because inhibitor ions occupy all sites of the immobilized enzyme.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Corrosion Reviews
Corrosion Reviews 工程技术-材料科学:膜
CiteScore
5.20
自引率
3.10%
发文量
44
审稿时长
4.5 months
期刊介绍: Corrosion Reviews is an international bimonthly journal devoted to critical reviews and, to a lesser extent, outstanding original articles that are key to advancing the understanding and application of corrosion science and engineering in the service of society. Papers may be of a theoretical, experimental or practical nature, provided that they make a significant contribution to knowledge in the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信