低温贮藏容器空气循环条件下温度平衡率与细胞生长/活力的比较

IF 0.8 4区 医学 Q4 ENGINEERING, BIOMEDICAL
Jeong-Yeon Park, Dong-won Lee, Sunray Lee, Dong-Mok Lee, Jienny Lee, Hyun-sook Park, G. Yoon
{"title":"低温贮藏容器空气循环条件下温度平衡率与细胞生长/活力的比较","authors":"Jeong-Yeon Park, Dong-won Lee, Sunray Lee, Dong-Mok Lee, Jienny Lee, Hyun-sook Park, G. Yoon","doi":"10.1115/1.4054833","DOIUrl":null,"url":null,"abstract":"\n With advances in biotechnology, the field of cryopreservation has been continuously developed and improved. Typical cryo-container was designed with minimal flow to avoid possible structural defects in LN2 tank, which has a higher thermal conductivity than vapor nitrogen tank. If cells are placed in typical cryo-container and stored in VN2 tank, cross-contamination can be prevented, but the cell viability after thawing may be reduced. The structure of typical cryo-containers are not optimized for vaporized nitrogen to flow quickly into the container and its circulation well. Therefore, we proposed new cryo-container models that can maintain mechanical strength while optimizing the fluid flow structure, and performed thermal-structural coupled field analysis on cryo-containers. We confirmed the cryo-containers by comparing the equivalent stress distributions formed around through holes and evaluating thermal equilibrium in the cryogenic steady state through flow analysis. Prototype cryo-containers and typical cryo-containers were placed in VN2 tank for a period of time to observe temperature changes. As a result, the time it takes to reach the temperature equilibrium has been reduced to 55% level compared with the typical cryo-containers. Additionally, C2C12 and hADMSC cells were checked after storage under two temperature conditions (-80 and -196°C). In both cell, viability, adhesion and relative cell proliferation were improved by up to 15-20% in new containers compared to typical products. The developed container is expected to maintain stability well by being applied to storage and transportation of advanced medicines that require cryopreservation.","PeriodicalId":49305,"journal":{"name":"Journal of Medical Devices-Transactions of the Asme","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2022-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of Temperature Equilibrium Rate and Cell Growth/Viability Under Air Circulation in Cryogenic Storage Container\",\"authors\":\"Jeong-Yeon Park, Dong-won Lee, Sunray Lee, Dong-Mok Lee, Jienny Lee, Hyun-sook Park, G. Yoon\",\"doi\":\"10.1115/1.4054833\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n With advances in biotechnology, the field of cryopreservation has been continuously developed and improved. Typical cryo-container was designed with minimal flow to avoid possible structural defects in LN2 tank, which has a higher thermal conductivity than vapor nitrogen tank. If cells are placed in typical cryo-container and stored in VN2 tank, cross-contamination can be prevented, but the cell viability after thawing may be reduced. The structure of typical cryo-containers are not optimized for vaporized nitrogen to flow quickly into the container and its circulation well. Therefore, we proposed new cryo-container models that can maintain mechanical strength while optimizing the fluid flow structure, and performed thermal-structural coupled field analysis on cryo-containers. We confirmed the cryo-containers by comparing the equivalent stress distributions formed around through holes and evaluating thermal equilibrium in the cryogenic steady state through flow analysis. Prototype cryo-containers and typical cryo-containers were placed in VN2 tank for a period of time to observe temperature changes. As a result, the time it takes to reach the temperature equilibrium has been reduced to 55% level compared with the typical cryo-containers. Additionally, C2C12 and hADMSC cells were checked after storage under two temperature conditions (-80 and -196°C). In both cell, viability, adhesion and relative cell proliferation were improved by up to 15-20% in new containers compared to typical products. The developed container is expected to maintain stability well by being applied to storage and transportation of advanced medicines that require cryopreservation.\",\"PeriodicalId\":49305,\"journal\":{\"name\":\"Journal of Medical Devices-Transactions of the Asme\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2022-06-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Devices-Transactions of the Asme\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4054833\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Devices-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4054833","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

随着生物技术的进步,冷冻保存领域不断发展和完善。典型的低温容器设计成具有最小流量,以避免LN2罐中可能存在的结构缺陷,LN2罐具有比蒸汽氮罐更高的热导率。如果将细胞放置在典型的冷冻容器中并储存在VN2罐中,可以防止交叉污染,但解冻后的细胞活力可能会降低。典型的低温容器的结构没有针对蒸发的氮气快速流入容器及其循环井中进行优化。因此,我们提出了新的低温容器模型,该模型可以在优化流体流动结构的同时保持机械强度,并对低温容器进行了热结构耦合场分析。我们通过比较通孔周围形成的等效应力分布,并通过流动分析评估低温稳态下的热平衡,来确认低温容器。将原型冷冻容器和典型冷冻容器放置在VN2罐中一段时间,以观察温度变化。因此,与典型的低温容器相比,达到温度平衡所需的时间已减少到55%。此外,在两种温度条件(-80和-196°C)下储存后,对C2C12和hADMSC细胞进行检查。在这两种细胞中,与典型产品相比,在新容器中,活力、粘附力和相对细胞增殖都提高了15-20%。开发的容器有望通过应用于需要冷冻保存的先进药物的储存和运输而保持良好的稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of Temperature Equilibrium Rate and Cell Growth/Viability Under Air Circulation in Cryogenic Storage Container
With advances in biotechnology, the field of cryopreservation has been continuously developed and improved. Typical cryo-container was designed with minimal flow to avoid possible structural defects in LN2 tank, which has a higher thermal conductivity than vapor nitrogen tank. If cells are placed in typical cryo-container and stored in VN2 tank, cross-contamination can be prevented, but the cell viability after thawing may be reduced. The structure of typical cryo-containers are not optimized for vaporized nitrogen to flow quickly into the container and its circulation well. Therefore, we proposed new cryo-container models that can maintain mechanical strength while optimizing the fluid flow structure, and performed thermal-structural coupled field analysis on cryo-containers. We confirmed the cryo-containers by comparing the equivalent stress distributions formed around through holes and evaluating thermal equilibrium in the cryogenic steady state through flow analysis. Prototype cryo-containers and typical cryo-containers were placed in VN2 tank for a period of time to observe temperature changes. As a result, the time it takes to reach the temperature equilibrium has been reduced to 55% level compared with the typical cryo-containers. Additionally, C2C12 and hADMSC cells were checked after storage under two temperature conditions (-80 and -196°C). In both cell, viability, adhesion and relative cell proliferation were improved by up to 15-20% in new containers compared to typical products. The developed container is expected to maintain stability well by being applied to storage and transportation of advanced medicines that require cryopreservation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.80
自引率
11.10%
发文量
56
审稿时长
6-12 weeks
期刊介绍: The Journal of Medical Devices presents papers on medical devices that improve diagnostic, interventional and therapeutic treatments focusing on applied research and the development of new medical devices or instrumentation. It provides special coverage of novel devices that allow new surgical strategies, new methods of drug delivery, or possible reductions in the complexity, cost, or adverse results of health care. The Design Innovation category features papers focusing on novel devices, including papers with limited clinical or engineering results. The Medical Device News section provides coverage of advances, trends, and events.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信