{"title":"考虑对称三相故障的高穿透并网光伏发电机组的扰动观测","authors":"Tha'er O. Sweidan, M. Widyan, M. Rifai","doi":"10.1504/IJPEC.2019.10018718","DOIUrl":null,"url":null,"abstract":"This paper presents perturbation and observation (P&O) as maximum power point tracking (MPPT) technique applied on grid-integrated PV generator. The interfacing is carried out via DC-DC buck-boost converter, three-phase sinusoidal DC-AC inverter, LC filter, transformer and two identical transmission lines. Large-signal stability analysis has been carried out considering symmetrical three-phase to ground fault as a case study at the middle of one of the transmission lines. The idea behind introducing the DC-DC converter is to adjust its duty cycle using the P&O algorithm such that to extract the maximum power available in the PV generator at all practical solar irradiance levels. The results show that the highly penetrated grid-integrated PV generator can keep the stability of its operating point despite the large-disturbance considered. It is also concluded that overshoot and settling time of the power system are highly affected by the fault clearing time and solar irradiance level. The higher the solar irradiance level is, the higher the critical clearing time, the larger the overshoot and the lower the settling time tend to be.","PeriodicalId":38524,"journal":{"name":"International Journal of Power and Energy Conversion","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Perturbation and observation as MPPT for highly penetrated grid-integrated PV generator considering symmetrical three-phase fault\",\"authors\":\"Tha'er O. Sweidan, M. Widyan, M. Rifai\",\"doi\":\"10.1504/IJPEC.2019.10018718\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents perturbation and observation (P&O) as maximum power point tracking (MPPT) technique applied on grid-integrated PV generator. The interfacing is carried out via DC-DC buck-boost converter, three-phase sinusoidal DC-AC inverter, LC filter, transformer and two identical transmission lines. Large-signal stability analysis has been carried out considering symmetrical three-phase to ground fault as a case study at the middle of one of the transmission lines. The idea behind introducing the DC-DC converter is to adjust its duty cycle using the P&O algorithm such that to extract the maximum power available in the PV generator at all practical solar irradiance levels. The results show that the highly penetrated grid-integrated PV generator can keep the stability of its operating point despite the large-disturbance considered. It is also concluded that overshoot and settling time of the power system are highly affected by the fault clearing time and solar irradiance level. The higher the solar irradiance level is, the higher the critical clearing time, the larger the overshoot and the lower the settling time tend to be.\",\"PeriodicalId\":38524,\"journal\":{\"name\":\"International Journal of Power and Energy Conversion\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Power and Energy Conversion\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1504/IJPEC.2019.10018718\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Energy\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Power and Energy Conversion","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1504/IJPEC.2019.10018718","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Energy","Score":null,"Total":0}
Perturbation and observation as MPPT for highly penetrated grid-integrated PV generator considering symmetrical three-phase fault
This paper presents perturbation and observation (P&O) as maximum power point tracking (MPPT) technique applied on grid-integrated PV generator. The interfacing is carried out via DC-DC buck-boost converter, three-phase sinusoidal DC-AC inverter, LC filter, transformer and two identical transmission lines. Large-signal stability analysis has been carried out considering symmetrical three-phase to ground fault as a case study at the middle of one of the transmission lines. The idea behind introducing the DC-DC converter is to adjust its duty cycle using the P&O algorithm such that to extract the maximum power available in the PV generator at all practical solar irradiance levels. The results show that the highly penetrated grid-integrated PV generator can keep the stability of its operating point despite the large-disturbance considered. It is also concluded that overshoot and settling time of the power system are highly affected by the fault clearing time and solar irradiance level. The higher the solar irradiance level is, the higher the critical clearing time, the larger the overshoot and the lower the settling time tend to be.
期刊介绍:
IJPEC highlights the latest trends in research in the field of power generation, transmission and distribution. Currently there exist significant challenges in the power sector, particularly in deregulated/restructured power markets. A key challenge to the operation, control and protection of the power system is the proliferation of power electronic devices within power systems. The main thrust of IJPEC is to disseminate the latest research trends in the power sector as well as in energy conversion technologies. Topics covered include: -Power system modelling and analysis -Computing and economics -FACTS and HVDC -Challenges in restructured energy systems -Power system control, operation, communications, SCADA -Power system relaying/protection -Energy management systems/distribution automation -Applications of power electronics to power systems -Power quality -Distributed generation and renewable energy sources -Electrical machines and drives -Utilisation of electrical energy -Modelling and control of machines -Fault diagnosis in machines and drives -Special machines