D. N. Katole, M. Daigavane, S. P. Gawande, P. Daigavane
{"title":"基于改进单相SRF -q理论的DVR非线性负载电压骤降控制","authors":"D. N. Katole, M. Daigavane, S. P. Gawande, P. Daigavane","doi":"10.4236/JEMAA.2017.92003","DOIUrl":null,"url":null,"abstract":"This paper mainly concentrates on design of improved controller and its implementation based on single phase synchronous reference frame theory (SRFT) for Dynamic Voltage Restorer (DVR) compensating voltage sag particularly for nonlinear load. In case of single phase distribution line with nonlinear load, the complexity of controller’s design becomes more serious issue. The present single phase and/or three phase theories applicable to DVR shows poor response to restore voltage sag in case of nonlinear load due to presence of harmonics. Hence restoration of voltage sag in single phase nonlinear load connected system has been a serious concern. Therefore, new controller for DVR has been proposed incorporating effective design concept for fundamental component extraction in case of nonlinear load. The single phase SRFT based main controller for DVR works on two separate closed path viz. feed forward path for quick transient response and feedback path for reducing the steady state error. Moreover, pre-sag mitigation strategy of DVR has been adapted through these two aforementioned paths. Complete design of proposed controller is based on phasor analysis. It also consist of proportional integral (PI) controller to reduce the error in the DC-link voltage during compensation time. The controller performance has been verified in MATLAB Simulink for both types (linear and nonlinear) of load. The results obtained indicates that the proposed controller is effective in its performance.","PeriodicalId":58231,"journal":{"name":"电磁分析与应用期刊(英文)","volume":"09 1","pages":"22-33"},"PeriodicalIF":0.0000,"publicationDate":"2017-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Modified Single Phase SRF d-q Theory Based Controller for DVR Mitigating Voltage Sag in Case of Nonlinear Load\",\"authors\":\"D. N. Katole, M. Daigavane, S. P. Gawande, P. Daigavane\",\"doi\":\"10.4236/JEMAA.2017.92003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper mainly concentrates on design of improved controller and its implementation based on single phase synchronous reference frame theory (SRFT) for Dynamic Voltage Restorer (DVR) compensating voltage sag particularly for nonlinear load. In case of single phase distribution line with nonlinear load, the complexity of controller’s design becomes more serious issue. The present single phase and/or three phase theories applicable to DVR shows poor response to restore voltage sag in case of nonlinear load due to presence of harmonics. Hence restoration of voltage sag in single phase nonlinear load connected system has been a serious concern. Therefore, new controller for DVR has been proposed incorporating effective design concept for fundamental component extraction in case of nonlinear load. The single phase SRFT based main controller for DVR works on two separate closed path viz. feed forward path for quick transient response and feedback path for reducing the steady state error. Moreover, pre-sag mitigation strategy of DVR has been adapted through these two aforementioned paths. Complete design of proposed controller is based on phasor analysis. It also consist of proportional integral (PI) controller to reduce the error in the DC-link voltage during compensation time. The controller performance has been verified in MATLAB Simulink for both types (linear and nonlinear) of load. The results obtained indicates that the proposed controller is effective in its performance.\",\"PeriodicalId\":58231,\"journal\":{\"name\":\"电磁分析与应用期刊(英文)\",\"volume\":\"09 1\",\"pages\":\"22-33\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-02-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"电磁分析与应用期刊(英文)\",\"FirstCategoryId\":\"1093\",\"ListUrlMain\":\"https://doi.org/10.4236/JEMAA.2017.92003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"电磁分析与应用期刊(英文)","FirstCategoryId":"1093","ListUrlMain":"https://doi.org/10.4236/JEMAA.2017.92003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

本文主要研究基于单相同步参考系理论(SRFT)的动态电压恢复器(DVR)补偿电压暂降的改进控制器的设计及其实现,特别是对非线性负载的补偿。在单相配电线路带非线性负载的情况下,控制器设计的复杂性问题更加突出。目前适用于DVR的单相和/或三相理论显示,在由于谐波的存在而导致的非线性负载的情况下,恢复电压暂降的响应较差。因此,单相非线性负载连接系统中电压暂降的恢复一直是一个备受关注的问题。因此,提出了一种新的DVR控制器,该控制器结合了在非线性负载情况下提取基本分量的有效设计理念。基于单相SRFT的DVR主控制器工作在两个独立的闭合路径上,即用于快速瞬态响应的前馈路径和用于减少稳态误差的反馈路径。此外,DVR的预下垂缓解策略也通过这两条路径进行了调整。所提出的控制器的完整设计基于相量分析。它还包括比例积分(PI)控制器,以减少补偿时间内直流链路电压的误差。控制器的性能已经在MATLAB Simulink中对两种类型(线性和非线性)的负载进行了验证。结果表明,所提出的控制器在性能上是有效的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Modified Single Phase SRF d-q Theory Based Controller for DVR Mitigating Voltage Sag in Case of Nonlinear Load
This paper mainly concentrates on design of improved controller and its implementation based on single phase synchronous reference frame theory (SRFT) for Dynamic Voltage Restorer (DVR) compensating voltage sag particularly for nonlinear load. In case of single phase distribution line with nonlinear load, the complexity of controller’s design becomes more serious issue. The present single phase and/or three phase theories applicable to DVR shows poor response to restore voltage sag in case of nonlinear load due to presence of harmonics. Hence restoration of voltage sag in single phase nonlinear load connected system has been a serious concern. Therefore, new controller for DVR has been proposed incorporating effective design concept for fundamental component extraction in case of nonlinear load. The single phase SRFT based main controller for DVR works on two separate closed path viz. feed forward path for quick transient response and feedback path for reducing the steady state error. Moreover, pre-sag mitigation strategy of DVR has been adapted through these two aforementioned paths. Complete design of proposed controller is based on phasor analysis. It also consist of proportional integral (PI) controller to reduce the error in the DC-link voltage during compensation time. The controller performance has been verified in MATLAB Simulink for both types (linear and nonlinear) of load. The results obtained indicates that the proposed controller is effective in its performance.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
441
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信