建筑设计与抗震规范的协调

IF 0.3 4区 艺术学 0 ARCHITECTURE
Prostor Pub Date : 2021-06-30 DOI:10.31522/p.29.1(61).4
Cengiz Özmen
{"title":"建筑设计与抗震规范的协调","authors":"Cengiz Özmen","doi":"10.31522/p.29.1(61).4","DOIUrl":null,"url":null,"abstract":"Seismic codes include strict requirements for the design and construction of mid-rise reinforced concrete residential buildings. These requirements call for the symmetric and regular arrangement of the structural system, increased cross-sections for columns, and the introduction of shear walls to counteract the effects of lateral seismic loads. It is challenging for architects to reconcile the demands of these codes with the spatial arrangement and commercial appeal of their designs.\nThis study argues that such reconciliation is possible through an architectural analysis. First, the effectiveness of applying the seismic design principles required by the codes is demonstrated with the comparative analysis of two finite element models. Then three pairs of architectural models, representing the most common floor plan arrangements for such buildings in Turkey, are architecturally analyzed before and after the application of seismic design principles in terms of floor area and access to view. The results demonstrate that within the context defined by the methodology of this study, considerable seismic achievement can be achieved in mid-rise reinforced concrete residential buildings by the application of relatively few, basic design features by the architects.","PeriodicalId":42738,"journal":{"name":"Prostor","volume":null,"pages":null},"PeriodicalIF":0.3000,"publicationDate":"2021-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Reconciling Architectural Design with Seismic Codes\",\"authors\":\"Cengiz Özmen\",\"doi\":\"10.31522/p.29.1(61).4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Seismic codes include strict requirements for the design and construction of mid-rise reinforced concrete residential buildings. These requirements call for the symmetric and regular arrangement of the structural system, increased cross-sections for columns, and the introduction of shear walls to counteract the effects of lateral seismic loads. It is challenging for architects to reconcile the demands of these codes with the spatial arrangement and commercial appeal of their designs.\\nThis study argues that such reconciliation is possible through an architectural analysis. First, the effectiveness of applying the seismic design principles required by the codes is demonstrated with the comparative analysis of two finite element models. Then three pairs of architectural models, representing the most common floor plan arrangements for such buildings in Turkey, are architecturally analyzed before and after the application of seismic design principles in terms of floor area and access to view. The results demonstrate that within the context defined by the methodology of this study, considerable seismic achievement can be achieved in mid-rise reinforced concrete residential buildings by the application of relatively few, basic design features by the architects.\",\"PeriodicalId\":42738,\"journal\":{\"name\":\"Prostor\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.3000,\"publicationDate\":\"2021-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Prostor\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31522/p.29.1(61).4\",\"RegionNum\":4,\"RegionCategory\":\"艺术学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"0\",\"JCRName\":\"ARCHITECTURE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Prostor","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31522/p.29.1(61).4","RegionNum":4,"RegionCategory":"艺术学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"0","JCRName":"ARCHITECTURE","Score":null,"Total":0}
引用次数: 1

摘要

抗震规范对中高层钢筋混凝土住宅的设计和施工提出了严格要求。这些要求要求结构系统的对称和规则布置,增加柱的横截面,并引入剪力墙来抵消横向地震荷载的影响。建筑师很难将这些规范的要求与设计的空间安排和商业吸引力相协调。这项研究认为,通过架构分析,这种协调是可能的。首先,通过对两个有限元模型的比较分析,证明了应用规范要求的抗震设计原则的有效性。然后,从建筑面积和视野角度,对应用抗震设计原则前后的三对建筑模型进行了建筑分析,这些模型代表了土耳其此类建筑最常见的平面布置。结果表明,在本研究方法所定义的背景下,通过建筑师应用相对较少的基本设计特征,可以在中高层钢筋混凝土住宅中取得相当大的抗震成就。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reconciling Architectural Design with Seismic Codes
Seismic codes include strict requirements for the design and construction of mid-rise reinforced concrete residential buildings. These requirements call for the symmetric and regular arrangement of the structural system, increased cross-sections for columns, and the introduction of shear walls to counteract the effects of lateral seismic loads. It is challenging for architects to reconcile the demands of these codes with the spatial arrangement and commercial appeal of their designs. This study argues that such reconciliation is possible through an architectural analysis. First, the effectiveness of applying the seismic design principles required by the codes is demonstrated with the comparative analysis of two finite element models. Then three pairs of architectural models, representing the most common floor plan arrangements for such buildings in Turkey, are architecturally analyzed before and after the application of seismic design principles in terms of floor area and access to view. The results demonstrate that within the context defined by the methodology of this study, considerable seismic achievement can be achieved in mid-rise reinforced concrete residential buildings by the application of relatively few, basic design features by the architects.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Prostor
Prostor ARCHITECTURE-
自引率
66.70%
发文量
10
审稿时长
12 weeks
期刊介绍: The journal PROSTOR publishes scientific papers from all branches of architecture and urban planning as well as texts from other fields of science (art history, archaeology, ethnology, sociology, geography, civil engineering, geodesy, forestry, design...) if their content relates to architectural issues.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信