III区REBOA和COBRA-OS™: 无意中使用髂动脉装置的安全性

IF 0.4 Q4 EMERGENCY MEDICINE
A. Power, Asha Parekh, Tyler S Beveridge, Adam M R Groh, Laura J Moore
{"title":"III区REBOA和COBRA-OS™: 无意中使用髂动脉装置的安全性","authors":"A. Power, Asha Parekh, Tyler S Beveridge, Adam M R Groh, Laura J Moore","doi":"10.26676/jevtm.v5i2.202","DOIUrl":null,"url":null,"abstract":"Background: REBOA is an emerging technique in trauma. However, inadvertent iliac artery balloon inflation can lead to complications. This study aims to investigate the safety characteristics of the COBRA-OS™ compared to a 7 Fr commercially available device during purposeful iliac artery balloon overinflation. \nMethods:  In vitro: the COBRA-OS™ was inflated in explanted porcine iliac arteries and intentionally overinflated until balloon or vessel rupture occurred. In vivo: the COBRA-OS™ and 7 Fr device were deployed in the iliac arteries and intentionally overinflated until rupture of the balloon or blood vessel. \nResults: In vitro: an average volume of 1mL was required for occlusion using the COBRA-OS™ and the mean balloon rupture volume was 32.5mL. The COBRA-OS™ partially migrated into the aorta in all cases. In vivo: the COBRA-OS™ and 7 Fr device occluded the iliac arteries with a mean volume of 3.5 mL.  Overinflation resulted in no iliac ruptures with the COBRA-OS™ (mean balloon rupture volume = 10mL). Overinflation with the 7 Fr device resulted in 1 iliac rupture at 5mL. The other two 7 Fr devices had a mean balloon rupture volume of 5 mL. All COBRA-OS™ devices moved partially up into the aorta during inflation while all 7 Fr devices remained in the iliac artery. \nConclusions: The COBRA-OS™ allows for significant overinflation when deployed in the common iliac artery of a porcine model due to its unique design. This ultimately may help to prevent balloon and blood vessel rupture during clinical use, however further studies are required.","PeriodicalId":41233,"journal":{"name":"Journal of EndoVascular Resuscitation and Trauma Management","volume":" ","pages":""},"PeriodicalIF":0.4000,"publicationDate":"2021-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Zone III REBOA and the COBRA-OS™: Safety of Inadvertent Iliac Artery Device Deployment\",\"authors\":\"A. Power, Asha Parekh, Tyler S Beveridge, Adam M R Groh, Laura J Moore\",\"doi\":\"10.26676/jevtm.v5i2.202\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: REBOA is an emerging technique in trauma. However, inadvertent iliac artery balloon inflation can lead to complications. This study aims to investigate the safety characteristics of the COBRA-OS™ compared to a 7 Fr commercially available device during purposeful iliac artery balloon overinflation. \\nMethods:  In vitro: the COBRA-OS™ was inflated in explanted porcine iliac arteries and intentionally overinflated until balloon or vessel rupture occurred. In vivo: the COBRA-OS™ and 7 Fr device were deployed in the iliac arteries and intentionally overinflated until rupture of the balloon or blood vessel. \\nResults: In vitro: an average volume of 1mL was required for occlusion using the COBRA-OS™ and the mean balloon rupture volume was 32.5mL. The COBRA-OS™ partially migrated into the aorta in all cases. In vivo: the COBRA-OS™ and 7 Fr device occluded the iliac arteries with a mean volume of 3.5 mL.  Overinflation resulted in no iliac ruptures with the COBRA-OS™ (mean balloon rupture volume = 10mL). Overinflation with the 7 Fr device resulted in 1 iliac rupture at 5mL. The other two 7 Fr devices had a mean balloon rupture volume of 5 mL. All COBRA-OS™ devices moved partially up into the aorta during inflation while all 7 Fr devices remained in the iliac artery. \\nConclusions: The COBRA-OS™ allows for significant overinflation when deployed in the common iliac artery of a porcine model due to its unique design. This ultimately may help to prevent balloon and blood vessel rupture during clinical use, however further studies are required.\",\"PeriodicalId\":41233,\"journal\":{\"name\":\"Journal of EndoVascular Resuscitation and Trauma Management\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2021-10-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of EndoVascular Resuscitation and Trauma Management\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.26676/jevtm.v5i2.202\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"EMERGENCY MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of EndoVascular Resuscitation and Trauma Management","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26676/jevtm.v5i2.202","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 1

摘要

背景:REBOA是一种新兴的创伤治疗技术。然而,不经意的髂动脉球囊扩张会导致并发症。本研究旨在调查COBRA-OS的安全特性™ 相比之下,在有目的的髂动脉球囊过度膨胀期间市售的7Fr装置。方法:体外:COBRA-OS™ 在移植的猪髂动脉中膨胀,并故意过度膨胀,直到发生球囊或血管破裂。体内:COBRA-OS™ 和7Fr装置被部署在髂动脉中并且故意过度膨胀直到球囊或血管破裂。结果:体外:使用COBRA-OS进行闭塞所需的平均体积为1mL™ 平均球囊破裂体积为32.5mL™ 所有病例均部分迁移至主动脉。体内:COBRA-OS™ 7 Fr封堵器闭塞髂动脉,平均体积为3.5mL。过度膨胀导致使用COBRA-OS的髂动脉未破裂™ (平均球囊破裂体积=10mL)。使用7Fr装置过度充气导致1例在5mL时髂骨破裂。另外两个7Fr装置的平均球囊破裂体积为5 mL™ 装置在充气期间部分向上移动到主动脉中,而所有7Fr装置都保留在髂动脉中。结论:COBRA-OS™ 由于其独特的设计,当部署在猪模型的髂总动脉中时允许显著的过度膨胀。这最终可能有助于在临床使用中防止球囊和血管破裂,但还需要进一步的研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Zone III REBOA and the COBRA-OS™: Safety of Inadvertent Iliac Artery Device Deployment
Background: REBOA is an emerging technique in trauma. However, inadvertent iliac artery balloon inflation can lead to complications. This study aims to investigate the safety characteristics of the COBRA-OS™ compared to a 7 Fr commercially available device during purposeful iliac artery balloon overinflation. Methods:  In vitro: the COBRA-OS™ was inflated in explanted porcine iliac arteries and intentionally overinflated until balloon or vessel rupture occurred. In vivo: the COBRA-OS™ and 7 Fr device were deployed in the iliac arteries and intentionally overinflated until rupture of the balloon or blood vessel. Results: In vitro: an average volume of 1mL was required for occlusion using the COBRA-OS™ and the mean balloon rupture volume was 32.5mL. The COBRA-OS™ partially migrated into the aorta in all cases. In vivo: the COBRA-OS™ and 7 Fr device occluded the iliac arteries with a mean volume of 3.5 mL.  Overinflation resulted in no iliac ruptures with the COBRA-OS™ (mean balloon rupture volume = 10mL). Overinflation with the 7 Fr device resulted in 1 iliac rupture at 5mL. The other two 7 Fr devices had a mean balloon rupture volume of 5 mL. All COBRA-OS™ devices moved partially up into the aorta during inflation while all 7 Fr devices remained in the iliac artery. Conclusions: The COBRA-OS™ allows for significant overinflation when deployed in the common iliac artery of a porcine model due to its unique design. This ultimately may help to prevent balloon and blood vessel rupture during clinical use, however further studies are required.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.60
自引率
25.00%
发文量
19
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信