尺桡关节远端伸肌腱移植术后肌腱长度和偏移的变化

S. Hashimoto, H. Kato, S. Uchiyama, T. Itsubo, S. Matsuda, M. Hayashi
{"title":"尺桡关节远端伸肌腱移植术后肌腱长度和偏移的变化","authors":"S. Hashimoto, H. Kato, S. Uchiyama, T. Itsubo, S. Matsuda, M. Hayashi","doi":"10.1177/17531934221103688","DOIUrl":null,"url":null,"abstract":"We evaluated the tendon length and excursion after extensor tendon grafting following ruptures at the distal radioulnar joint in eight patients. The mean patient age was 70.8 years (range 58 to 84), and the mean follow-up period was 63 months (range 12 to 129). Radiographic markers were placed on ends of the grafted tendon to assess changes in length and passive excursion. The mean length of the grafted tendon and mean passive excursion were 68.2 mm and 4.4 mm immediately after tendon grafting, 76.1 mm and 7.1 mm at 1 year postoperatively, and 76.3 mm and 7.3 mm at final follow-up, respectively. The mean elongation of the grafted tendon was 12% and mean increase of excursion was 2.9 mm. We recommend that tension set during extensor tendon grafting should be with the metacarpophalangeal joint of the affected finger in a slightly extended position as compared with adjacent fingers. Level of evidence IV","PeriodicalId":73762,"journal":{"name":"Journal of hand surgery (Edinburgh, Scotland)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Changes in tendon length and excursion following extensor tendon grafting at the distal radioulnar joint\",\"authors\":\"S. Hashimoto, H. Kato, S. Uchiyama, T. Itsubo, S. Matsuda, M. Hayashi\",\"doi\":\"10.1177/17531934221103688\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We evaluated the tendon length and excursion after extensor tendon grafting following ruptures at the distal radioulnar joint in eight patients. The mean patient age was 70.8 years (range 58 to 84), and the mean follow-up period was 63 months (range 12 to 129). Radiographic markers were placed on ends of the grafted tendon to assess changes in length and passive excursion. The mean length of the grafted tendon and mean passive excursion were 68.2 mm and 4.4 mm immediately after tendon grafting, 76.1 mm and 7.1 mm at 1 year postoperatively, and 76.3 mm and 7.3 mm at final follow-up, respectively. The mean elongation of the grafted tendon was 12% and mean increase of excursion was 2.9 mm. We recommend that tension set during extensor tendon grafting should be with the metacarpophalangeal joint of the affected finger in a slightly extended position as compared with adjacent fingers. Level of evidence IV\",\"PeriodicalId\":73762,\"journal\":{\"name\":\"Journal of hand surgery (Edinburgh, Scotland)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of hand surgery (Edinburgh, Scotland)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/17531934221103688\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of hand surgery (Edinburgh, Scotland)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/17531934221103688","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

我们评估了8例患者桡尺远端关节断裂后伸肌腱移植后的肌腱长度和偏移。患者平均年龄为70.8岁(58至84岁),平均随访期为63个月(12至129岁)。在移植肌腱末端放置射线照相标记,以评估长度和被动偏移的变化。移植肌腱的平均长度和平均被动偏移为68.2 mm和4.4 肌腱移植后即刻为76.1 mm和7.1 术后1年为76.3 mm和7.3 mm。移植肌腱的平均伸长率为12%,偏移的平均增加量为2.9 mm。我们建议在伸肌腱移植过程中,与相邻手指相比,受影响手指的掌指关节应处于略微伸展的位置。证据级别IV
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Changes in tendon length and excursion following extensor tendon grafting at the distal radioulnar joint
We evaluated the tendon length and excursion after extensor tendon grafting following ruptures at the distal radioulnar joint in eight patients. The mean patient age was 70.8 years (range 58 to 84), and the mean follow-up period was 63 months (range 12 to 129). Radiographic markers were placed on ends of the grafted tendon to assess changes in length and passive excursion. The mean length of the grafted tendon and mean passive excursion were 68.2 mm and 4.4 mm immediately after tendon grafting, 76.1 mm and 7.1 mm at 1 year postoperatively, and 76.3 mm and 7.3 mm at final follow-up, respectively. The mean elongation of the grafted tendon was 12% and mean increase of excursion was 2.9 mm. We recommend that tension set during extensor tendon grafting should be with the metacarpophalangeal joint of the affected finger in a slightly extended position as compared with adjacent fingers. Level of evidence IV
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信