高效液相色谱法同时测定原料药中还原型和氧化型谷胱甘肽的开发与验证

N. Singh, Akhtar Mj, A. Anchliya
{"title":"高效液相色谱法同时测定原料药中还原型和氧化型谷胱甘肽的开发与验证","authors":"N. Singh, Akhtar Mj, A. Anchliya","doi":"10.26420/AUSTININTERNMED.2021.1129","DOIUrl":null,"url":null,"abstract":"The objective of this study was the development, optimization, and validation of a RP-HPLC method for the quantification of reduced glutathione (GSH) and oxidized glutathione (GSSG) in pharmaceutical formulations The separation utilized a C18 column at room temperature with absorption wavelength 210nm. The mobile phase was an isocratic flow of a 95:5 (v/v) mixture of 25mM phosphate buffer (pH 2.7) and methanol with flow rate at 1.0 mL/min. Validation of the method assessed with the methods ability in seven categories: linearity, range, limit of detection, limit of quantification, accuracy, precision, and selectivity. The method show an acceptable degree of linearity with r²=0.9994 and 0.999 over a concentration range of 10-200 μg/mL for GSH and GSSG respectively. The detection limit and quantification limit for GSH 20.7μg/mL and 69.24μg/mL and for GSSG 17.22μg/mL and 57.42μg/mL respectively. The percent recovery of the method was 99.98-100.93 %. Following validation, the method was employed in the determination of glutathione in pharmaceutical formulations in the form of a liposome. The proposed method offers a simple, accurate, and inexpensive way to quantify reduced glutathione.","PeriodicalId":91055,"journal":{"name":"Austin journal of analytical and pharmaceutical chemistry","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Development and Validation of HPLC Method for Simultaneous Estimation of Reduced and Oxidized Glutathione in Bulk Pharmaceutical Formulation\",\"authors\":\"N. Singh, Akhtar Mj, A. Anchliya\",\"doi\":\"10.26420/AUSTININTERNMED.2021.1129\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The objective of this study was the development, optimization, and validation of a RP-HPLC method for the quantification of reduced glutathione (GSH) and oxidized glutathione (GSSG) in pharmaceutical formulations The separation utilized a C18 column at room temperature with absorption wavelength 210nm. The mobile phase was an isocratic flow of a 95:5 (v/v) mixture of 25mM phosphate buffer (pH 2.7) and methanol with flow rate at 1.0 mL/min. Validation of the method assessed with the methods ability in seven categories: linearity, range, limit of detection, limit of quantification, accuracy, precision, and selectivity. The method show an acceptable degree of linearity with r²=0.9994 and 0.999 over a concentration range of 10-200 μg/mL for GSH and GSSG respectively. The detection limit and quantification limit for GSH 20.7μg/mL and 69.24μg/mL and for GSSG 17.22μg/mL and 57.42μg/mL respectively. The percent recovery of the method was 99.98-100.93 %. Following validation, the method was employed in the determination of glutathione in pharmaceutical formulations in the form of a liposome. The proposed method offers a simple, accurate, and inexpensive way to quantify reduced glutathione.\",\"PeriodicalId\":91055,\"journal\":{\"name\":\"Austin journal of analytical and pharmaceutical chemistry\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-03-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Austin journal of analytical and pharmaceutical chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.26420/AUSTININTERNMED.2021.1129\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Austin journal of analytical and pharmaceutical chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26420/AUSTININTERNMED.2021.1129","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本研究的目的是开发、优化和验证RP-HPLC方法,用于定量药物制剂中的还原型谷胱甘肽(GSH)和氧化型谷胱甘肽(GSSG)。分离采用C18柱,室温下,吸收波长210nm。流动相为25mM磷酸盐缓冲液(pH 2.7)和甲醇的95∶5(v/v)混合物的等度流,流速为1.0mL/min。通过七类方法能力评估方法的有效性:线性、范围、检测限、定量限、准确度、精密度和选择性。该方法在10-200μg/mL的GSH和GSSG浓度范围内显示出可接受的线性度,r²分别为0.9994和0.999。GSH的检测限和定量限分别为20.7μg/mL和69.24μg/mL,GSSG分别为17.22μg/mL、57.42μg/mL。方法的回收率为99.98~100.93%。验证后,该方法被用于脂质体形式的药物制剂中谷胱甘肽的测定。所提出的方法提供了一种简单、准确和廉价的方法来量化还原型谷胱甘肽。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development and Validation of HPLC Method for Simultaneous Estimation of Reduced and Oxidized Glutathione in Bulk Pharmaceutical Formulation
The objective of this study was the development, optimization, and validation of a RP-HPLC method for the quantification of reduced glutathione (GSH) and oxidized glutathione (GSSG) in pharmaceutical formulations The separation utilized a C18 column at room temperature with absorption wavelength 210nm. The mobile phase was an isocratic flow of a 95:5 (v/v) mixture of 25mM phosphate buffer (pH 2.7) and methanol with flow rate at 1.0 mL/min. Validation of the method assessed with the methods ability in seven categories: linearity, range, limit of detection, limit of quantification, accuracy, precision, and selectivity. The method show an acceptable degree of linearity with r²=0.9994 and 0.999 over a concentration range of 10-200 μg/mL for GSH and GSSG respectively. The detection limit and quantification limit for GSH 20.7μg/mL and 69.24μg/mL and for GSSG 17.22μg/mL and 57.42μg/mL respectively. The percent recovery of the method was 99.98-100.93 %. Following validation, the method was employed in the determination of glutathione in pharmaceutical formulations in the form of a liposome. The proposed method offers a simple, accurate, and inexpensive way to quantify reduced glutathione.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信