人工湿地-微生物燃料电池系统中污染物去除和微生物活性的季节性变化

IF 2.3 Q2 Environmental Science
Xiaoou Wang, Yi-mei Tian
{"title":"人工湿地-微生物燃料电池系统中污染物去除和微生物活性的季节性变化","authors":"Xiaoou Wang, Yi-mei Tian","doi":"10.2166/WRD.2021.094","DOIUrl":null,"url":null,"abstract":"\n This study investigated the seasonal variations of pollutants removal and microbial activity in constructed wetland–microbial fuel cell systems (CW–MFCs). The results showed that the atmospheric temperature significantly influenced the bioelectricity generation and removal of organics and nitrogen in CW–MFCs by primarily influencing the microbial enzymatic activity. The electricity output of CW-MFCs was extremely low below 5 °C, and reached the maximum above 25 °C. The organics and nitrogen removal of closed-circuit CW–MFC reached the highest in summer and autumn, followed by spring, and decreased by an average of 10.5% COD, 14.2% NH3-N and 10.7% TN in winter, demonstrating smaller seasonal fluctuations compared to open-circuit CW–MFC in which the difference between summer and winter was 13.4% COD, 15.1% NH3-N and 15.1% TN. Even at low temperatures, the MFC current could enhance the enzymatic activity and stabilize the growth of microorganisms on the electrodes, moreover, the closed circuit operation can promote the bacteria diversity on CW–MFC anodes as well as the abundance of electrogens on CW–MFC anodes and cathodes, and thus reduce the adverse effect of cooling on organics and nitrogen removal in CWs. However, neither MFC nor temperature had a significant influence on phosphorus removal in CW–MFCs.","PeriodicalId":17556,"journal":{"name":"Journal of Water Reuse and Desalination","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2021-03-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Seasonal variations of pollutants removal and microbial activity in integrated constructed wetland–microbial fuel cell systems\",\"authors\":\"Xiaoou Wang, Yi-mei Tian\",\"doi\":\"10.2166/WRD.2021.094\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n This study investigated the seasonal variations of pollutants removal and microbial activity in constructed wetland–microbial fuel cell systems (CW–MFCs). The results showed that the atmospheric temperature significantly influenced the bioelectricity generation and removal of organics and nitrogen in CW–MFCs by primarily influencing the microbial enzymatic activity. The electricity output of CW-MFCs was extremely low below 5 °C, and reached the maximum above 25 °C. The organics and nitrogen removal of closed-circuit CW–MFC reached the highest in summer and autumn, followed by spring, and decreased by an average of 10.5% COD, 14.2% NH3-N and 10.7% TN in winter, demonstrating smaller seasonal fluctuations compared to open-circuit CW–MFC in which the difference between summer and winter was 13.4% COD, 15.1% NH3-N and 15.1% TN. Even at low temperatures, the MFC current could enhance the enzymatic activity and stabilize the growth of microorganisms on the electrodes, moreover, the closed circuit operation can promote the bacteria diversity on CW–MFC anodes as well as the abundance of electrogens on CW–MFC anodes and cathodes, and thus reduce the adverse effect of cooling on organics and nitrogen removal in CWs. However, neither MFC nor temperature had a significant influence on phosphorus removal in CW–MFCs.\",\"PeriodicalId\":17556,\"journal\":{\"name\":\"Journal of Water Reuse and Desalination\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2021-03-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Water Reuse and Desalination\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2166/WRD.2021.094\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Environmental Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Water Reuse and Desalination","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2166/WRD.2021.094","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Environmental Science","Score":null,"Total":0}
引用次数: 8

摘要

研究了人工湿地-微生物燃料电池系统(cw - mfc)中污染物去除和微生物活性的季节变化。结果表明,大气温度主要通过影响微生物酶活性来显著影响cw - mfc生物发电和有机物、氮的去除。cw - mfc的输出功率在5℃以下极低,在25℃以上达到最大值。闭路CW-MFC的有机物和氮去除率在夏季和秋季最高,春季次之,冬季COD平均下降10.5%,NH3-N平均下降14.2%,TN平均下降10.7%,与开路CW-MFC的夏季和冬季差异13.4%,NH3-N平均下降15.1%,TN平均下降15.1%相比,季节波动较小。MFC电流可以增强酶活性,稳定电极上微生物的生长,并且闭环操作可以促进CW-MFC阳极上细菌的多样性以及w - MFC阳极和阴极上电的丰度,从而减少冷却对cw中有机物和氮去除的不利影响。而MFC和温度对cw - MFC除磷均无显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Seasonal variations of pollutants removal and microbial activity in integrated constructed wetland–microbial fuel cell systems
This study investigated the seasonal variations of pollutants removal and microbial activity in constructed wetland–microbial fuel cell systems (CW–MFCs). The results showed that the atmospheric temperature significantly influenced the bioelectricity generation and removal of organics and nitrogen in CW–MFCs by primarily influencing the microbial enzymatic activity. The electricity output of CW-MFCs was extremely low below 5 °C, and reached the maximum above 25 °C. The organics and nitrogen removal of closed-circuit CW–MFC reached the highest in summer and autumn, followed by spring, and decreased by an average of 10.5% COD, 14.2% NH3-N and 10.7% TN in winter, demonstrating smaller seasonal fluctuations compared to open-circuit CW–MFC in which the difference between summer and winter was 13.4% COD, 15.1% NH3-N and 15.1% TN. Even at low temperatures, the MFC current could enhance the enzymatic activity and stabilize the growth of microorganisms on the electrodes, moreover, the closed circuit operation can promote the bacteria diversity on CW–MFC anodes as well as the abundance of electrogens on CW–MFC anodes and cathodes, and thus reduce the adverse effect of cooling on organics and nitrogen removal in CWs. However, neither MFC nor temperature had a significant influence on phosphorus removal in CW–MFCs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Water Reuse and Desalination
Journal of Water Reuse and Desalination ENGINEERING, ENVIRONMENTAL-WATER RESOURCES
CiteScore
4.30
自引率
0.00%
发文量
23
审稿时长
16 weeks
期刊介绍: Journal of Water Reuse and Desalination publishes refereed review articles, theoretical and experimental research papers, new findings and issues of unplanned and planned reuse. The journal welcomes contributions from developing and developed countries.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信