{"title":"膝关节外骨骼系统的分数阶多回路自抗扰控制","authors":"N. A. Al-awad, A. Humaidi, A. Al-Araji","doi":"10.14311/ap.2023.63.0158","DOIUrl":null,"url":null,"abstract":"Rehabilitation Exoskeleton is becoming more and more important in physiotherapists’ routine work. To improve the treatment performance, such as reducing the recovery period and/or monitoring and reacting to unpredictable situations, the rehabilitation manipulators need to help the patients in various physical trainings. A special case of the active disturbance rejection control (ADRC) is applied to govern a proper realisation of basic limb rehabilitation trainings. The experimental study is performed on a model of a flexible joint manipulator, whose behaviour resembles a real exoskeleton rehabilitation device (a one-degree-of-freedom, rigid-link, flexible-joint manipulator). The fractional (FADRC) is an unconventional model-independent approach, acknowledged as an effective controller in the existence of total plant uncertainties, and these uncertainties are inclusive of the total disturbances and unknown dynamics of the plant. In this work, three FADRC schemes are used, the first one using a fractional state observer (FSO), or FADRC1, second one using a fractional proportional-derivative controller (FPD), or FADRC2, and the third one a Multi-loop fractional in PD-loop controller and the observer-loop (Feedforward and Feedback), or FADRC3. The simulated Exoskeleton system is subjected to a noise disturbance and the FADRC3 shows the effectiveness to compensate all these effects and satisfies the desired position when compared with FADRC1 and FADRC2. The design and simulation were carried out in MATLAB/Simulink.","PeriodicalId":45804,"journal":{"name":"Acta Polytechnica","volume":" ","pages":""},"PeriodicalIF":0.6000,"publicationDate":"2023-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fractional multi-loop active disturbance rejection control for a lower knee exoskeleton system\",\"authors\":\"N. A. Al-awad, A. Humaidi, A. Al-Araji\",\"doi\":\"10.14311/ap.2023.63.0158\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Rehabilitation Exoskeleton is becoming more and more important in physiotherapists’ routine work. To improve the treatment performance, such as reducing the recovery period and/or monitoring and reacting to unpredictable situations, the rehabilitation manipulators need to help the patients in various physical trainings. A special case of the active disturbance rejection control (ADRC) is applied to govern a proper realisation of basic limb rehabilitation trainings. The experimental study is performed on a model of a flexible joint manipulator, whose behaviour resembles a real exoskeleton rehabilitation device (a one-degree-of-freedom, rigid-link, flexible-joint manipulator). The fractional (FADRC) is an unconventional model-independent approach, acknowledged as an effective controller in the existence of total plant uncertainties, and these uncertainties are inclusive of the total disturbances and unknown dynamics of the plant. In this work, three FADRC schemes are used, the first one using a fractional state observer (FSO), or FADRC1, second one using a fractional proportional-derivative controller (FPD), or FADRC2, and the third one a Multi-loop fractional in PD-loop controller and the observer-loop (Feedforward and Feedback), or FADRC3. The simulated Exoskeleton system is subjected to a noise disturbance and the FADRC3 shows the effectiveness to compensate all these effects and satisfies the desired position when compared with FADRC1 and FADRC2. The design and simulation were carried out in MATLAB/Simulink.\",\"PeriodicalId\":45804,\"journal\":{\"name\":\"Acta Polytechnica\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2023-07-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Polytechnica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14311/ap.2023.63.0158\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Polytechnica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14311/ap.2023.63.0158","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
Fractional multi-loop active disturbance rejection control for a lower knee exoskeleton system
Rehabilitation Exoskeleton is becoming more and more important in physiotherapists’ routine work. To improve the treatment performance, such as reducing the recovery period and/or monitoring and reacting to unpredictable situations, the rehabilitation manipulators need to help the patients in various physical trainings. A special case of the active disturbance rejection control (ADRC) is applied to govern a proper realisation of basic limb rehabilitation trainings. The experimental study is performed on a model of a flexible joint manipulator, whose behaviour resembles a real exoskeleton rehabilitation device (a one-degree-of-freedom, rigid-link, flexible-joint manipulator). The fractional (FADRC) is an unconventional model-independent approach, acknowledged as an effective controller in the existence of total plant uncertainties, and these uncertainties are inclusive of the total disturbances and unknown dynamics of the plant. In this work, three FADRC schemes are used, the first one using a fractional state observer (FSO), or FADRC1, second one using a fractional proportional-derivative controller (FPD), or FADRC2, and the third one a Multi-loop fractional in PD-loop controller and the observer-loop (Feedforward and Feedback), or FADRC3. The simulated Exoskeleton system is subjected to a noise disturbance and the FADRC3 shows the effectiveness to compensate all these effects and satisfies the desired position when compared with FADRC1 and FADRC2. The design and simulation were carried out in MATLAB/Simulink.
期刊介绍:
Acta Polytechnica is a scientific journal published by CTU in Prague. The main title, Acta Polytechnica, is accompanied by the subtitle Journal of Advanced Engineering, which defines the scope of the journal more precisely - Acta Polytechnica covers a wide spectrum of engineering topics, physics and mathematics. Our aim is to be a high-quality multi-disciplinary journal publishing the results of basic research and also applied research. We place emphasis on the quality of all published papers. The journal should also serve as a bridge between basic research in natural sciences and applied research in all technical disciplines. The innovative research results published by young researchers or by postdoctoral fellows, and also the high-quality papers by researchers from the international scientific community, reflect the good position of CTU in the World University Rankings. We hope that you will find our journal interesting, and that it will serve as a valuable source of scientific information.