{"title":"微孔板减振器在降低铁路曲线噪声中的应用","authors":"Woong-yong Lee, Jae-chul Kim, H. Noh","doi":"10.3397/1/376948","DOIUrl":null,"url":null,"abstract":"A micro-perforated panel absorber (MPPA) can reduce noise without the use of sound-absorbing materials. It is made of various materials and is poten- tially applicable in a variety of fields. However, the application of MPPAs is limited owing to the narrow absorption band. In a previous\n study, to enhance the sound- absorption performance of MPPAs, we proposed a parallel arrangement of multi- layer MPPAs. Based on the results of this previous study, we carried out the present study to apply an MPPA to the curve squeal noise of railways. Squeal noise, which occurs at approximately\n 500 to 5000 Hz, has high-level peaks. We designed and fabricated an MPPAwith the proposed structure according to the characteris- tics of the squeal noise. The noise reduction was analyzed after an MPPA barrier was installed in the field with a curve radius of 120 m. The reduction in noise\n level was approximately 17 dB(A) on the first floor and approximately 7 dB(A) on the fourth floor of the building. At 630 to 5000 Hz, the noise reduction level was at least approximately 5 dB(A). To analyze the noise absorption effect of the MPPA bar- rier, a simulation was carried out and\n subsequently verified by comparing the measurement results with the simulation results. In the simulation, the difference in noise reduction level between the MPPA and reflective barrier was analyzed. The noise reduction level of the MPPA barrier was approximately 7.5 dB(A) higher than that\n of the reflective barrier on the second and third floors of the build- ing at 630 to 5000 Hz. These results support the viability of MPPA application in re- ducing noise from curve squeal noise.","PeriodicalId":49748,"journal":{"name":"Noise Control Engineering Journal","volume":" ","pages":""},"PeriodicalIF":0.3000,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Application of a micro-perforated panel absorber to reduce the curve squeal noise of railways\",\"authors\":\"Woong-yong Lee, Jae-chul Kim, H. Noh\",\"doi\":\"10.3397/1/376948\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A micro-perforated panel absorber (MPPA) can reduce noise without the use of sound-absorbing materials. It is made of various materials and is poten- tially applicable in a variety of fields. However, the application of MPPAs is limited owing to the narrow absorption band. In a previous\\n study, to enhance the sound- absorption performance of MPPAs, we proposed a parallel arrangement of multi- layer MPPAs. Based on the results of this previous study, we carried out the present study to apply an MPPA to the curve squeal noise of railways. Squeal noise, which occurs at approximately\\n 500 to 5000 Hz, has high-level peaks. We designed and fabricated an MPPAwith the proposed structure according to the characteris- tics of the squeal noise. The noise reduction was analyzed after an MPPA barrier was installed in the field with a curve radius of 120 m. The reduction in noise\\n level was approximately 17 dB(A) on the first floor and approximately 7 dB(A) on the fourth floor of the building. At 630 to 5000 Hz, the noise reduction level was at least approximately 5 dB(A). To analyze the noise absorption effect of the MPPA bar- rier, a simulation was carried out and\\n subsequently verified by comparing the measurement results with the simulation results. In the simulation, the difference in noise reduction level between the MPPA and reflective barrier was analyzed. The noise reduction level of the MPPA barrier was approximately 7.5 dB(A) higher than that\\n of the reflective barrier on the second and third floors of the build- ing at 630 to 5000 Hz. These results support the viability of MPPA application in re- ducing noise from curve squeal noise.\",\"PeriodicalId\":49748,\"journal\":{\"name\":\"Noise Control Engineering Journal\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.3000,\"publicationDate\":\"2021-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Noise Control Engineering Journal\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3397/1/376948\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Noise Control Engineering Journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3397/1/376948","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ACOUSTICS","Score":null,"Total":0}
Application of a micro-perforated panel absorber to reduce the curve squeal noise of railways
A micro-perforated panel absorber (MPPA) can reduce noise without the use of sound-absorbing materials. It is made of various materials and is poten- tially applicable in a variety of fields. However, the application of MPPAs is limited owing to the narrow absorption band. In a previous
study, to enhance the sound- absorption performance of MPPAs, we proposed a parallel arrangement of multi- layer MPPAs. Based on the results of this previous study, we carried out the present study to apply an MPPA to the curve squeal noise of railways. Squeal noise, which occurs at approximately
500 to 5000 Hz, has high-level peaks. We designed and fabricated an MPPAwith the proposed structure according to the characteris- tics of the squeal noise. The noise reduction was analyzed after an MPPA barrier was installed in the field with a curve radius of 120 m. The reduction in noise
level was approximately 17 dB(A) on the first floor and approximately 7 dB(A) on the fourth floor of the building. At 630 to 5000 Hz, the noise reduction level was at least approximately 5 dB(A). To analyze the noise absorption effect of the MPPA bar- rier, a simulation was carried out and
subsequently verified by comparing the measurement results with the simulation results. In the simulation, the difference in noise reduction level between the MPPA and reflective barrier was analyzed. The noise reduction level of the MPPA barrier was approximately 7.5 dB(A) higher than that
of the reflective barrier on the second and third floors of the build- ing at 630 to 5000 Hz. These results support the viability of MPPA application in re- ducing noise from curve squeal noise.
期刊介绍:
NCEJ is the pre-eminent academic journal of noise control. It is the International Journal of the Institute of Noise Control Engineering of the USA. It is also produced with the participation and assistance of the Korean Society of Noise and Vibration Engineering (KSNVE).
NCEJ reaches noise control professionals around the world, covering over 50 national noise control societies and institutes.
INCE encourages you to submit your next paper to NCEJ. Choosing NCEJ:
Provides the opportunity to reach a global audience of NCE professionals, academics, and students;
Enhances the prestige of your work;
Validates your work by formal peer review.