{"title":"导管测绘时代右室流出道起源的心电图预测算法的价值","authors":"Raluca Sirbu Prisecaru, L. Riahi, M. Abagiu, O. Purcar, I. Manițiu","doi":"10.55453/rjmm.2023.126.4.3","DOIUrl":null,"url":null,"abstract":"Background: The 12-lead electrocardiogram (ECG) is an extremely useful tool for analyzing cardiac arrhythmias and numerous ECG algorithms have been developed to predict the origin of right ventricular outflow tract (RVOT) arrhythmias. Aim: To determine if using complex, time-consuming analysis, and difficult-to-memorize ECG algorithms is feasible and preferable before the ablation procedure when compared with the use of multipolar mapping catheter use during the ablation procedure. Methods: 47 consecutive patients admitted for radiofrequency catheter ablation of idiopathic PVC were included prospectively in this study. Of the algorithms selected for comparison, three have a memorable design and easy applicability (Dixit, Joshi, Pytkowski) and the fourth has a complex, detailed design and is more difficult to memorize (Zhang). Results: The greatest accuracy was observed for the algorithms proposed by Dixit and Pytkowski – 92. 3%. However, when the algorithms were compared for their accuracy, specificity, and sensitivity, no significant differences were found (p=0. 96). Conclusions: 3-D guided mapping using a conventional ablation catheter in a narrower, precise area of interest in the RVOT, based on ECG algorithms is not inferior compared to the multielectrode catheter mapping in the whole RVOT, in terms of mapping time, total procedural time, and radiofrequency application time.","PeriodicalId":21298,"journal":{"name":"Romanian Journal of Military Medicine","volume":null,"pages":null},"PeriodicalIF":0.1000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Value of Electrocardiogram Algorithms Predicting Right Ventricular Outflow Tract Origin in the Era of Catheter Mapping\",\"authors\":\"Raluca Sirbu Prisecaru, L. Riahi, M. Abagiu, O. Purcar, I. Manițiu\",\"doi\":\"10.55453/rjmm.2023.126.4.3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: The 12-lead electrocardiogram (ECG) is an extremely useful tool for analyzing cardiac arrhythmias and numerous ECG algorithms have been developed to predict the origin of right ventricular outflow tract (RVOT) arrhythmias. Aim: To determine if using complex, time-consuming analysis, and difficult-to-memorize ECG algorithms is feasible and preferable before the ablation procedure when compared with the use of multipolar mapping catheter use during the ablation procedure. Methods: 47 consecutive patients admitted for radiofrequency catheter ablation of idiopathic PVC were included prospectively in this study. Of the algorithms selected for comparison, three have a memorable design and easy applicability (Dixit, Joshi, Pytkowski) and the fourth has a complex, detailed design and is more difficult to memorize (Zhang). Results: The greatest accuracy was observed for the algorithms proposed by Dixit and Pytkowski – 92. 3%. However, when the algorithms were compared for their accuracy, specificity, and sensitivity, no significant differences were found (p=0. 96). Conclusions: 3-D guided mapping using a conventional ablation catheter in a narrower, precise area of interest in the RVOT, based on ECG algorithms is not inferior compared to the multielectrode catheter mapping in the whole RVOT, in terms of mapping time, total procedural time, and radiofrequency application time.\",\"PeriodicalId\":21298,\"journal\":{\"name\":\"Romanian Journal of Military Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.1000,\"publicationDate\":\"2023-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Romanian Journal of Military Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.55453/rjmm.2023.126.4.3\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Romanian Journal of Military Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.55453/rjmm.2023.126.4.3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

摘要

背景:12导联心电图(ECG)是一种非常有用的分析心律失常的工具,许多ECG算法已被开发用于预测右心室流出道(RVOT)心律失常的起源。目的:比较在消融过程中使用多极定位导管与在消融过程中使用多极定位导管相比,在消融前使用复杂、耗时且难以记忆的ECG算法是否可行和可取。方法:前瞻性研究纳入47例连续接受特发性PVC射频导管消融治疗的患者。在选择进行比较的算法中,有三个算法具有令人难忘的设计和易于应用(Dixit, Joshi, Pytkowski),而第四个算法具有复杂,详细的设计并且更难以记忆(Zhang)。结果:Dixit和Pytkowski - 92提出的算法精度最高。3%。然而,当比较算法的准确性、特异性和敏感性时,没有发现显著差异(p=0。96)。结论:基于ECG算法,在RVOT中更窄、更精确的兴趣区域使用传统消融导管进行三维引导测绘,在整个RVOT中,在测绘时间、总手术时间和射频应用时间方面,与多电极导管测绘相比并不逊色。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Value of Electrocardiogram Algorithms Predicting Right Ventricular Outflow Tract Origin in the Era of Catheter Mapping
Background: The 12-lead electrocardiogram (ECG) is an extremely useful tool for analyzing cardiac arrhythmias and numerous ECG algorithms have been developed to predict the origin of right ventricular outflow tract (RVOT) arrhythmias. Aim: To determine if using complex, time-consuming analysis, and difficult-to-memorize ECG algorithms is feasible and preferable before the ablation procedure when compared with the use of multipolar mapping catheter use during the ablation procedure. Methods: 47 consecutive patients admitted for radiofrequency catheter ablation of idiopathic PVC were included prospectively in this study. Of the algorithms selected for comparison, three have a memorable design and easy applicability (Dixit, Joshi, Pytkowski) and the fourth has a complex, detailed design and is more difficult to memorize (Zhang). Results: The greatest accuracy was observed for the algorithms proposed by Dixit and Pytkowski – 92. 3%. However, when the algorithms were compared for their accuracy, specificity, and sensitivity, no significant differences were found (p=0. 96). Conclusions: 3-D guided mapping using a conventional ablation catheter in a narrower, precise area of interest in the RVOT, based on ECG algorithms is not inferior compared to the multielectrode catheter mapping in the whole RVOT, in terms of mapping time, total procedural time, and radiofrequency application time.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Romanian Journal of Military Medicine
Romanian Journal of Military Medicine MEDICINE, GENERAL & INTERNAL-
自引率
33.30%
发文量
2
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信