激光焊接不锈钢正畸丝的腐蚀

IF 0.5 Q4 DENTISTRY, ORAL SURGERY & MEDICINE
Takeshi Muguruma, Masahiro Iijima, Itaru Mizoguchi
{"title":"激光焊接不锈钢正畸丝的腐蚀","authors":"Takeshi Muguruma,&nbsp;Masahiro Iijima,&nbsp;Itaru Mizoguchi","doi":"10.1016/j.odw.2017.12.004","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>Fabricating orthodontic<span> appliances using laser welding has the clinical advantage of biocompatibility, because the welded joint does not require soldered alloy. The purpose of this study was to investigate the corrosion of laser-welded stainless steel wires in acidic environments.</span></p></div><div><h3>Materials and methods</h3><p>Laser welding of stainless steel wires with a 0.021<!--> <!-->×<!--> <!-->0.025 in cross-section was performed at an energy output ranging from 0.5 to 1.3<!--> <span><span>kW. A control sample was prepared using conventional soldering. The samples were immersed in 1% lactic acid aqueous solution for 7 days. After immersion, the concentrations of metallic ions in solution were measured using </span>inductively coupled plasma atomic emission spectroscopy. Tensile loading tests were carried out with and without lactic acid immersion. Scanning electron microscopy was used to examine the microstructure of laser-welded samples.</span></p></div><div><h3>Results</h3><p>The concentrations of metallic ions detected in solution for laser-welded samples were significantly lower than that for soldered sample. There was no significant difference among the mean tensile strengths with and without immersion for laser-welded samples. The penetration depth and the localized region fused by laser irradiation increased with energy output, and ductile fractures were observed in the fused region of laser-welded samples.</p></div><div><h3>Conclusion</h3><p>Laser welding of stainless steel orthodontic wires should be acceptable for clinical use, because the joints showed sufficient strength and the original structure was not significantly altered. Immersion in acidic solution had minimal effect on the mechanical performance at the joint regions, and showed minimal acceleration of metallic ion release.</p></div>","PeriodicalId":43169,"journal":{"name":"Orthodontic Waves","volume":"77 1","pages":"Pages 18-23"},"PeriodicalIF":0.5000,"publicationDate":"2018-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.odw.2017.12.004","citationCount":"6","resultStr":"{\"title\":\"Corrosion of laser-welded stainless steel orthodontic wires\",\"authors\":\"Takeshi Muguruma,&nbsp;Masahiro Iijima,&nbsp;Itaru Mizoguchi\",\"doi\":\"10.1016/j.odw.2017.12.004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Purpose</h3><p>Fabricating orthodontic<span> appliances using laser welding has the clinical advantage of biocompatibility, because the welded joint does not require soldered alloy. The purpose of this study was to investigate the corrosion of laser-welded stainless steel wires in acidic environments.</span></p></div><div><h3>Materials and methods</h3><p>Laser welding of stainless steel wires with a 0.021<!--> <!-->×<!--> <!-->0.025 in cross-section was performed at an energy output ranging from 0.5 to 1.3<!--> <span><span>kW. A control sample was prepared using conventional soldering. The samples were immersed in 1% lactic acid aqueous solution for 7 days. After immersion, the concentrations of metallic ions in solution were measured using </span>inductively coupled plasma atomic emission spectroscopy. Tensile loading tests were carried out with and without lactic acid immersion. Scanning electron microscopy was used to examine the microstructure of laser-welded samples.</span></p></div><div><h3>Results</h3><p>The concentrations of metallic ions detected in solution for laser-welded samples were significantly lower than that for soldered sample. There was no significant difference among the mean tensile strengths with and without immersion for laser-welded samples. The penetration depth and the localized region fused by laser irradiation increased with energy output, and ductile fractures were observed in the fused region of laser-welded samples.</p></div><div><h3>Conclusion</h3><p>Laser welding of stainless steel orthodontic wires should be acceptable for clinical use, because the joints showed sufficient strength and the original structure was not significantly altered. Immersion in acidic solution had minimal effect on the mechanical performance at the joint regions, and showed minimal acceleration of metallic ion release.</p></div>\",\"PeriodicalId\":43169,\"journal\":{\"name\":\"Orthodontic Waves\",\"volume\":\"77 1\",\"pages\":\"Pages 18-23\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2018-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.odw.2017.12.004\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Orthodontic Waves\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1344024117301814\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthodontic Waves","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1344024117301814","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 6

摘要

目的激光焊接制造正畸矫治器具有生物相容性强的临床优势,焊接接头不需要焊接合金。本研究的目的是研究激光焊接不锈钢丝在酸性环境中的腐蚀。材料和方法在0.5 ~ 1.3 kW的功率输出下,对截面为0.021 × 0.025的不锈钢丝进行激光焊接。采用常规焊接工艺制备对照样品。样品在1%乳酸水溶液中浸泡7天。浸泡后,用电感耦合等离子体原子发射光谱法测定溶液中金属离子的浓度。在乳酸浸泡和不浸泡的情况下进行拉伸加载试验。采用扫描电镜对激光焊接试样的显微组织进行了观察。结果激光焊接样品溶液中金属离子的检测浓度明显低于焊接样品。激光焊接试样浸泡前后的平均抗拉强度无显著差异。随着能量输出的增加,激光辐照的熔透深度和局部熔接区域增加,熔接区域出现韧性断裂。结论激光焊接不锈钢正畸丝,其关节强度足够,且对原有结构无明显改变,可用于临床。浸泡在酸性溶液中对接头区域的力学性能影响最小,金属离子释放的加速最小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Corrosion of laser-welded stainless steel orthodontic wires

Purpose

Fabricating orthodontic appliances using laser welding has the clinical advantage of biocompatibility, because the welded joint does not require soldered alloy. The purpose of this study was to investigate the corrosion of laser-welded stainless steel wires in acidic environments.

Materials and methods

Laser welding of stainless steel wires with a 0.021 × 0.025 in cross-section was performed at an energy output ranging from 0.5 to 1.3 kW. A control sample was prepared using conventional soldering. The samples were immersed in 1% lactic acid aqueous solution for 7 days. After immersion, the concentrations of metallic ions in solution were measured using inductively coupled plasma atomic emission spectroscopy. Tensile loading tests were carried out with and without lactic acid immersion. Scanning electron microscopy was used to examine the microstructure of laser-welded samples.

Results

The concentrations of metallic ions detected in solution for laser-welded samples were significantly lower than that for soldered sample. There was no significant difference among the mean tensile strengths with and without immersion for laser-welded samples. The penetration depth and the localized region fused by laser irradiation increased with energy output, and ductile fractures were observed in the fused region of laser-welded samples.

Conclusion

Laser welding of stainless steel orthodontic wires should be acceptable for clinical use, because the joints showed sufficient strength and the original structure was not significantly altered. Immersion in acidic solution had minimal effect on the mechanical performance at the joint regions, and showed minimal acceleration of metallic ion release.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Orthodontic Waves
Orthodontic Waves DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
0.40
自引率
0.00%
发文量
0
期刊介绍: Orthodontic Waves is the official publication of the Japanese Orthodontic Society. The aim of this journal is to foster the advancement of orthodontic research and practice. The journal seeks to publish original articles (i) definitive reports of wide interest to the orthodontic community, (ii) Case Reports and (iii) Short Communications. Research papers stand on the scientific basis of orthodontics. Clinical topics covered include all techniques and approaches to treatment planning. All submissions are subject to peer review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信