{"title":"在低收入和中等收入国家使用的任务转移避孕植入插入装置的临床前评估","authors":"I. Mohedas, Carrie Bell, Betregiorgis Hailu Zegeye, KevinC Jiang, Caroline Soyars, Madeleine Walsh, K. Sienko","doi":"10.1115/1.4054684","DOIUrl":null,"url":null,"abstract":"\n Worldwide, 225 million women have unmet contraceptive needs which, every year, leads to 52 million unintended pregnancies. A challenge to providing universal access to contraception is the large proportion of the population living in rural, difficult to access settings in low- and middle-income countries. The availability and delivery of effective contraception in rural areas is limited by the lack of trained healthcare providers. Barriers to the use of long-acting contraceptives in rural areas are more pronounced due to the advanced skill and training to administer. In this study, we describe the design and testing of the SubQ Assist, a task-shifting contraceptive implant insertion device that aims to reduce the training requirements for administering contraceptive implants while simultaneously ensuring safe and high quality administration. Cadaver testing in conjunction with ultrasound depth measurements were used to evaluate the efficacy of the SubQ Assist. Implant insertion between the SubQ Assist and a trained physician are compared. Cadaver testing and ultrasound depth measurements demonstrate that the SubQ Assist results in implant insertions that are statistically equivalent to implants inserted by a trained physician. Additionally, the results show that the lateral positioning of these implants would facilitate uncomplicated removal at a later date. These findings demonstrate proof of concept for the SubQ Assist and provide evidence for moving towards clinical testing. They demonstrate that the SubQ Assist may be an effective method of task-shifting the insertion of contraceptive implants to minimally trained providers in order to expand access in rural areas.","PeriodicalId":49305,"journal":{"name":"Journal of Medical Devices-Transactions of the Asme","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2022-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Pre-Clinical Evaluation of a Task-Shifting Contraceptive Implant Insertion Device for Use in Low- and Middle-Income Countries\",\"authors\":\"I. Mohedas, Carrie Bell, Betregiorgis Hailu Zegeye, KevinC Jiang, Caroline Soyars, Madeleine Walsh, K. Sienko\",\"doi\":\"10.1115/1.4054684\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Worldwide, 225 million women have unmet contraceptive needs which, every year, leads to 52 million unintended pregnancies. A challenge to providing universal access to contraception is the large proportion of the population living in rural, difficult to access settings in low- and middle-income countries. The availability and delivery of effective contraception in rural areas is limited by the lack of trained healthcare providers. Barriers to the use of long-acting contraceptives in rural areas are more pronounced due to the advanced skill and training to administer. In this study, we describe the design and testing of the SubQ Assist, a task-shifting contraceptive implant insertion device that aims to reduce the training requirements for administering contraceptive implants while simultaneously ensuring safe and high quality administration. Cadaver testing in conjunction with ultrasound depth measurements were used to evaluate the efficacy of the SubQ Assist. Implant insertion between the SubQ Assist and a trained physician are compared. Cadaver testing and ultrasound depth measurements demonstrate that the SubQ Assist results in implant insertions that are statistically equivalent to implants inserted by a trained physician. Additionally, the results show that the lateral positioning of these implants would facilitate uncomplicated removal at a later date. These findings demonstrate proof of concept for the SubQ Assist and provide evidence for moving towards clinical testing. They demonstrate that the SubQ Assist may be an effective method of task-shifting the insertion of contraceptive implants to minimally trained providers in order to expand access in rural areas.\",\"PeriodicalId\":49305,\"journal\":{\"name\":\"Journal of Medical Devices-Transactions of the Asme\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2022-05-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Devices-Transactions of the Asme\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4054684\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Devices-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4054684","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Pre-Clinical Evaluation of a Task-Shifting Contraceptive Implant Insertion Device for Use in Low- and Middle-Income Countries
Worldwide, 225 million women have unmet contraceptive needs which, every year, leads to 52 million unintended pregnancies. A challenge to providing universal access to contraception is the large proportion of the population living in rural, difficult to access settings in low- and middle-income countries. The availability and delivery of effective contraception in rural areas is limited by the lack of trained healthcare providers. Barriers to the use of long-acting contraceptives in rural areas are more pronounced due to the advanced skill and training to administer. In this study, we describe the design and testing of the SubQ Assist, a task-shifting contraceptive implant insertion device that aims to reduce the training requirements for administering contraceptive implants while simultaneously ensuring safe and high quality administration. Cadaver testing in conjunction with ultrasound depth measurements were used to evaluate the efficacy of the SubQ Assist. Implant insertion between the SubQ Assist and a trained physician are compared. Cadaver testing and ultrasound depth measurements demonstrate that the SubQ Assist results in implant insertions that are statistically equivalent to implants inserted by a trained physician. Additionally, the results show that the lateral positioning of these implants would facilitate uncomplicated removal at a later date. These findings demonstrate proof of concept for the SubQ Assist and provide evidence for moving towards clinical testing. They demonstrate that the SubQ Assist may be an effective method of task-shifting the insertion of contraceptive implants to minimally trained providers in order to expand access in rural areas.
期刊介绍:
The Journal of Medical Devices presents papers on medical devices that improve diagnostic, interventional and therapeutic treatments focusing on applied research and the development of new medical devices or instrumentation. It provides special coverage of novel devices that allow new surgical strategies, new methods of drug delivery, or possible reductions in the complexity, cost, or adverse results of health care. The Design Innovation category features papers focusing on novel devices, including papers with limited clinical or engineering results. The Medical Device News section provides coverage of advances, trends, and events.