改良的新冠肺炎肺炎玻璃窗胸部X射线成像技术和辐射剂量

IF 0.2 Q4 MEDICINE, RESEARCH & EXPERIMENTAL
I. Suliman, G. Khouqeer, N. Ahmed, M. Abuzaid, A. Sulieman
{"title":"改良的新冠肺炎肺炎玻璃窗胸部X射线成像技术和辐射剂量","authors":"I. Suliman, G. Khouqeer, N. Ahmed, M. Abuzaid, A. Sulieman","doi":"10.21103/article13(2)_ra2","DOIUrl":null,"url":null,"abstract":"The requirement for infection control during the COVID-19 pandemic led to modifying the exposure parameters in conventional radiography for performing chest X-ray radiography (CXR) through-the-glass (TTG) for imaging COVID-19 pneumonia. Herein, we reviewed and reported the current experiences with the TTG protocol, and summarized the current implementation strategies and modified technique factors. For implementing TTG techniques, measurements are required in a simulated environment using a patient equivalent phantom, and a certain number of investigations must be performed before the patient examination. However, the TTG technique requires modification due to the decrease in photon intensity caused by the attenuation in the glass barrier. This study discussed factors affecting CXR and some related radiation dose terminology required for implementing the TTG technique. Moreover, it summarized the exposure factors of CXR using the TTG technique compared with the standard CXR. Radiation exposure to the patient and the staff using the TTG technique remains within the recommended limits for safe practice. Image quality issues arose following the implementation of the TTG technique, mainly related to suboptimal positioning; image artifacts resulted due to glass attenuation, the increased source-to-image distance (SID), and patient movement. Overall, the reviewed results in this study could help formulate international guidelines and recommendations for the TTG technique for COVID-19 patient imaging, thereby minimizing the cost and time required for setting up the protocol.","PeriodicalId":53991,"journal":{"name":"International Journal of Biomedicine","volume":" ","pages":""},"PeriodicalIF":0.2000,"publicationDate":"2023-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Modified Chest X-Ray Radiography through Glass Window for Imaging COVID-19 Pneumonia: Techniques and Radiation Dose\",\"authors\":\"I. Suliman, G. Khouqeer, N. Ahmed, M. Abuzaid, A. Sulieman\",\"doi\":\"10.21103/article13(2)_ra2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The requirement for infection control during the COVID-19 pandemic led to modifying the exposure parameters in conventional radiography for performing chest X-ray radiography (CXR) through-the-glass (TTG) for imaging COVID-19 pneumonia. Herein, we reviewed and reported the current experiences with the TTG protocol, and summarized the current implementation strategies and modified technique factors. For implementing TTG techniques, measurements are required in a simulated environment using a patient equivalent phantom, and a certain number of investigations must be performed before the patient examination. However, the TTG technique requires modification due to the decrease in photon intensity caused by the attenuation in the glass barrier. This study discussed factors affecting CXR and some related radiation dose terminology required for implementing the TTG technique. Moreover, it summarized the exposure factors of CXR using the TTG technique compared with the standard CXR. Radiation exposure to the patient and the staff using the TTG technique remains within the recommended limits for safe practice. Image quality issues arose following the implementation of the TTG technique, mainly related to suboptimal positioning; image artifacts resulted due to glass attenuation, the increased source-to-image distance (SID), and patient movement. Overall, the reviewed results in this study could help formulate international guidelines and recommendations for the TTG technique for COVID-19 patient imaging, thereby minimizing the cost and time required for setting up the protocol.\",\"PeriodicalId\":53991,\"journal\":{\"name\":\"International Journal of Biomedicine\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2023-06-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Biomedicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21103/article13(2)_ra2\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Biomedicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21103/article13(2)_ra2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

新冠肺炎大流行期间对感染控制的要求导致修改了常规放射线照相术中的暴露参数,以进行胸部X射线透视(CXR)穿透玻璃(TTG)成像新冠肺炎肺炎。在此,我们回顾并报告了TTG协议的当前经验,并总结了当前的实施策略和修改的技术因素。为了实施TTG技术,需要在模拟环境中使用患者等效体模进行测量,并且在患者检查之前必须进行一定数量的调查。然而,由于玻璃屏障中的衰减导致光子强度降低,TTG技术需要修改。本研究讨论了影响CXR的因素以及实施TTG技术所需的一些相关辐射剂量术语。此外,还总结了使用TTG技术与标准CXR进行比较的CXR暴露因素。使用TTG技术的患者和工作人员的辐射暴露量仍在安全操作的建议范围内。TTG技术实施后出现了图像质量问题,主要与次优定位有关;图像伪影是由于玻璃衰减、源到图像距离(SID)的增加和患者的移动造成的。总体而言,本研究的审查结果有助于为新冠肺炎患者成像的TTG技术制定国际指南和建议,从而最大限度地减少制定方案所需的成本和时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Modified Chest X-Ray Radiography through Glass Window for Imaging COVID-19 Pneumonia: Techniques and Radiation Dose
The requirement for infection control during the COVID-19 pandemic led to modifying the exposure parameters in conventional radiography for performing chest X-ray radiography (CXR) through-the-glass (TTG) for imaging COVID-19 pneumonia. Herein, we reviewed and reported the current experiences with the TTG protocol, and summarized the current implementation strategies and modified technique factors. For implementing TTG techniques, measurements are required in a simulated environment using a patient equivalent phantom, and a certain number of investigations must be performed before the patient examination. However, the TTG technique requires modification due to the decrease in photon intensity caused by the attenuation in the glass barrier. This study discussed factors affecting CXR and some related radiation dose terminology required for implementing the TTG technique. Moreover, it summarized the exposure factors of CXR using the TTG technique compared with the standard CXR. Radiation exposure to the patient and the staff using the TTG technique remains within the recommended limits for safe practice. Image quality issues arose following the implementation of the TTG technique, mainly related to suboptimal positioning; image artifacts resulted due to glass attenuation, the increased source-to-image distance (SID), and patient movement. Overall, the reviewed results in this study could help formulate international guidelines and recommendations for the TTG technique for COVID-19 patient imaging, thereby minimizing the cost and time required for setting up the protocol.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Biomedicine
International Journal of Biomedicine MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
0.60
自引率
33.30%
发文量
90
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信