{"title":"Donnan膜电化学法测定游离Eu(III):实施与评价","authors":"Noémie Janot,&nbsp;Jan E. Groenenberg,&nbsp;Alba Otero-Fariña,&nbsp;José Paulo Pinheiro","doi":"10.1007/s10498-021-09392-4","DOIUrl":null,"url":null,"abstract":"<div><p>The aim of this study was to develop an analytical method to determine free concentrations of Europium (Eu(III)) in natural waters. Europium(III) in solution was detected using cathodic stripping voltammetry after complexation with <i>N</i>-nitroso-<i>N</i>-phenylhydroxylamine (cupferron). Optimization of analytical parameters allowed us to detect nanomolar levels of Eu(III) in solution. Free Eu(III) in solution was measured using the Donnan membrane technique in which a natural solution (the “donor”, containing various ligands) is separated from a ligand-free solution (the “acceptor”) by a cation-exchange membrane. This membrane allows only non-colloidal cationic species to pass through it, and after an adequate time equilibrium is reached between both compartments. Total Eu(III) concentration can then be quantified in the acceptor solution and related to free Eu(III) in the natural sample. Due to its high valency, free Eu(III) tends to adsorb strongly to the cation-exchange membrane. In order to determine the physicochemical conditions minimizing this adsorption, we analyzed solutions of different Eu(III) and Ca(II) (as background ion) concentrations. Results showed that 100 mM of Ca(II) were necessary to make adsorption of Eu(III) onto the membrane negligible. The optimized setup was then used to quantify Eu(III) complexation in a Eu(III)-dissolved organic matter solution.</p></div>","PeriodicalId":8102,"journal":{"name":"Aquatic Geochemistry","volume":"27 2","pages":"127 - 140"},"PeriodicalIF":1.7000,"publicationDate":"2021-02-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s10498-021-09392-4","citationCount":"4","resultStr":"{\"title\":\"Free Eu(III) Determination by Donnan Membrane Technique with Electrochemical Detection: Implementation and Evaluation\",\"authors\":\"Noémie Janot,&nbsp;Jan E. Groenenberg,&nbsp;Alba Otero-Fariña,&nbsp;José Paulo Pinheiro\",\"doi\":\"10.1007/s10498-021-09392-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The aim of this study was to develop an analytical method to determine free concentrations of Europium (Eu(III)) in natural waters. Europium(III) in solution was detected using cathodic stripping voltammetry after complexation with <i>N</i>-nitroso-<i>N</i>-phenylhydroxylamine (cupferron). Optimization of analytical parameters allowed us to detect nanomolar levels of Eu(III) in solution. Free Eu(III) in solution was measured using the Donnan membrane technique in which a natural solution (the “donor”, containing various ligands) is separated from a ligand-free solution (the “acceptor”) by a cation-exchange membrane. This membrane allows only non-colloidal cationic species to pass through it, and after an adequate time equilibrium is reached between both compartments. Total Eu(III) concentration can then be quantified in the acceptor solution and related to free Eu(III) in the natural sample. Due to its high valency, free Eu(III) tends to adsorb strongly to the cation-exchange membrane. In order to determine the physicochemical conditions minimizing this adsorption, we analyzed solutions of different Eu(III) and Ca(II) (as background ion) concentrations. Results showed that 100 mM of Ca(II) were necessary to make adsorption of Eu(III) onto the membrane negligible. The optimized setup was then used to quantify Eu(III) complexation in a Eu(III)-dissolved organic matter solution.</p></div>\",\"PeriodicalId\":8102,\"journal\":{\"name\":\"Aquatic Geochemistry\",\"volume\":\"27 2\",\"pages\":\"127 - 140\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2021-02-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1007/s10498-021-09392-4\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Aquatic Geochemistry\",\"FirstCategoryId\":\"89\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s10498-021-09392-4\",\"RegionNum\":4,\"RegionCategory\":\"地球科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"GEOCHEMISTRY & GEOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Aquatic Geochemistry","FirstCategoryId":"89","ListUrlMain":"https://link.springer.com/article/10.1007/s10498-021-09392-4","RegionNum":4,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"GEOCHEMISTRY & GEOPHYSICS","Score":null,"Total":0}
引用次数: 4

摘要

本研究的目的是建立一种测定天然水体中游离铕(Eu(III))浓度的分析方法。用n -亚硝基-n -苯基羟胺(铜铁)络合后的阴极溶出伏安法检测溶液中的铕(III)。优化分析参数使我们能够检测溶液中Eu(III)的纳摩尔水平。使用Donnan膜技术测量溶液中的游离Eu(III),其中天然溶液(含有各种配体的“供体”)通过阳离子交换膜与无配体溶液(“受体”)分离。这种膜只允许非胶体阳离子物质通过它,在足够的时间后,两个隔室之间达到平衡。然后可以在受体溶液中量化总Eu(III)浓度,并将其与天然样品中的游离Eu(III)相关联。由于其价高,游离Eu(III)倾向于在阳离子交换膜上强烈吸附。为了确定减少这种吸附的物理化学条件,我们分析了不同浓度的Eu(III)和Ca(II)(作为背景离子)溶液。结果表明,100 mM的Ca(II)可以使膜上的Eu(III)吸附忽略不计。然后利用优化后的装置定量Eu(III)在Eu(III)溶解有机物溶液中的络合作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Free Eu(III) Determination by Donnan Membrane Technique with Electrochemical Detection: Implementation and Evaluation

The aim of this study was to develop an analytical method to determine free concentrations of Europium (Eu(III)) in natural waters. Europium(III) in solution was detected using cathodic stripping voltammetry after complexation with N-nitroso-N-phenylhydroxylamine (cupferron). Optimization of analytical parameters allowed us to detect nanomolar levels of Eu(III) in solution. Free Eu(III) in solution was measured using the Donnan membrane technique in which a natural solution (the “donor”, containing various ligands) is separated from a ligand-free solution (the “acceptor”) by a cation-exchange membrane. This membrane allows only non-colloidal cationic species to pass through it, and after an adequate time equilibrium is reached between both compartments. Total Eu(III) concentration can then be quantified in the acceptor solution and related to free Eu(III) in the natural sample. Due to its high valency, free Eu(III) tends to adsorb strongly to the cation-exchange membrane. In order to determine the physicochemical conditions minimizing this adsorption, we analyzed solutions of different Eu(III) and Ca(II) (as background ion) concentrations. Results showed that 100 mM of Ca(II) were necessary to make adsorption of Eu(III) onto the membrane negligible. The optimized setup was then used to quantify Eu(III) complexation in a Eu(III)-dissolved organic matter solution.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Aquatic Geochemistry
Aquatic Geochemistry 地学-地球化学与地球物理
CiteScore
4.30
自引率
0.00%
发文量
6
审稿时长
1 months
期刊介绍: We publish original studies relating to the geochemistry of natural waters and their interactions with rocks and minerals under near Earth-surface conditions. Coverage includes theoretical, experimental, and modeling papers dealing with this subject area, as well as papers presenting observations of natural systems that stress major processes. The journal also presents `letter''-type papers for rapid publication and a limited number of review-type papers on topics of particularly broad interest or current major controversy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信