K. Perry, R. Staruch, S. Pichardo, Yuexi Huang, M. McGuffin, A. Partanen, Shun Wong, G. Czarnota, K. Hynynen, Kelvin K. W. Chan, W. Chu
{"title":"磁共振引导高强度聚焦超声(MR-HIFU)热疗治疗原发性癌症:一项虚拟可行性分析。","authors":"K. Perry, R. Staruch, S. Pichardo, Yuexi Huang, M. McGuffin, A. Partanen, Shun Wong, G. Czarnota, K. Hynynen, Kelvin K. W. Chan, W. Chu","doi":"10.1200/jgo.2019.5.suppl.77","DOIUrl":null,"url":null,"abstract":"77 Background: MR-HIFU Hyperthermia (HT) is a non-invasive treatment modality with real-time thermometry that ensures accurate and precise heating of a target with minimal effect on adjacent tissue. This energy deposition within a tumour can produce local bioeffects resulting in thermal chemo- and radiosensitization. MR-HIFU has been shown to be safe and feasible in a companion phase I study for recurrent rectal cancer. The purpose of this study is to determine the feasibility of MR-HIFU in treating primary rectal tumours. Methods: With ethics approval, the anatomic characteristics and surrounding structures of rectal tumours diagnosed at Sunnybrook from 2014-2019 were retrospectively analyzed. Three orthogonal views of MR images were used to determine the potential ultrasound (US) beam path and organs at risk (OAR). In part 2 of the study, the gross tumour volume was delineated for 30 rectal tumours (10 low, mid &high). Image datasets were imported into the Sonalleve MR-HIFU workstation for virtual treatment simulation and planning to determine tumour targetability, coverage, optimal patient set-up, and transducer positioning. Results: Of the 105 tumours analyzed, 36, 52, and 17 were low, mid, and high, respectively. The average width of the acoustic window (sciatic notch) for the US beam path was 5.8 ± 1.4cm, average tumour length was 5.24 ± 2.0cm, and average beam path (skin to tumour edge) was 7.3 ± 1.9cm. Eighty one percent of tumours were ≤ 0.3cm from an OAR. Of the 24 virtually simulated tumours to date, 6/8 lower, 6/8 mid, and 1/8 upper rectal tumours were targetable by MR-HIFU. Conclusions: This is the first virtual analysis to evaluate MR-HIFU HT targetability in primary rectal cancer. Results from this study will support MR-HIFU HT as an option to enhance the treatment of primary rectal cancer. Acknowledgments: This study has been funded by the Canadian Cancer Society. Patient & tumour characteristics. [Table: see text]","PeriodicalId":15862,"journal":{"name":"Journal of global oncology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Magnetic resonance-guided high intensity focused ultrasound (MR-HIFU) hyperthermia for primary rectal cancer: A virtual feasibility analysis.\",\"authors\":\"K. Perry, R. Staruch, S. Pichardo, Yuexi Huang, M. McGuffin, A. Partanen, Shun Wong, G. Czarnota, K. Hynynen, Kelvin K. W. Chan, W. Chu\",\"doi\":\"10.1200/jgo.2019.5.suppl.77\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"77 Background: MR-HIFU Hyperthermia (HT) is a non-invasive treatment modality with real-time thermometry that ensures accurate and precise heating of a target with minimal effect on adjacent tissue. This energy deposition within a tumour can produce local bioeffects resulting in thermal chemo- and radiosensitization. MR-HIFU has been shown to be safe and feasible in a companion phase I study for recurrent rectal cancer. The purpose of this study is to determine the feasibility of MR-HIFU in treating primary rectal tumours. Methods: With ethics approval, the anatomic characteristics and surrounding structures of rectal tumours diagnosed at Sunnybrook from 2014-2019 were retrospectively analyzed. Three orthogonal views of MR images were used to determine the potential ultrasound (US) beam path and organs at risk (OAR). In part 2 of the study, the gross tumour volume was delineated for 30 rectal tumours (10 low, mid &high). Image datasets were imported into the Sonalleve MR-HIFU workstation for virtual treatment simulation and planning to determine tumour targetability, coverage, optimal patient set-up, and transducer positioning. Results: Of the 105 tumours analyzed, 36, 52, and 17 were low, mid, and high, respectively. The average width of the acoustic window (sciatic notch) for the US beam path was 5.8 ± 1.4cm, average tumour length was 5.24 ± 2.0cm, and average beam path (skin to tumour edge) was 7.3 ± 1.9cm. Eighty one percent of tumours were ≤ 0.3cm from an OAR. Of the 24 virtually simulated tumours to date, 6/8 lower, 6/8 mid, and 1/8 upper rectal tumours were targetable by MR-HIFU. Conclusions: This is the first virtual analysis to evaluate MR-HIFU HT targetability in primary rectal cancer. Results from this study will support MR-HIFU HT as an option to enhance the treatment of primary rectal cancer. Acknowledgments: This study has been funded by the Canadian Cancer Society. Patient & tumour characteristics. [Table: see text]\",\"PeriodicalId\":15862,\"journal\":{\"name\":\"Journal of global oncology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of global oncology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1200/jgo.2019.5.suppl.77\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of global oncology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1200/jgo.2019.5.suppl.77","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Magnetic resonance-guided high intensity focused ultrasound (MR-HIFU) hyperthermia for primary rectal cancer: A virtual feasibility analysis.
77 Background: MR-HIFU Hyperthermia (HT) is a non-invasive treatment modality with real-time thermometry that ensures accurate and precise heating of a target with minimal effect on adjacent tissue. This energy deposition within a tumour can produce local bioeffects resulting in thermal chemo- and radiosensitization. MR-HIFU has been shown to be safe and feasible in a companion phase I study for recurrent rectal cancer. The purpose of this study is to determine the feasibility of MR-HIFU in treating primary rectal tumours. Methods: With ethics approval, the anatomic characteristics and surrounding structures of rectal tumours diagnosed at Sunnybrook from 2014-2019 were retrospectively analyzed. Three orthogonal views of MR images were used to determine the potential ultrasound (US) beam path and organs at risk (OAR). In part 2 of the study, the gross tumour volume was delineated for 30 rectal tumours (10 low, mid &high). Image datasets were imported into the Sonalleve MR-HIFU workstation for virtual treatment simulation and planning to determine tumour targetability, coverage, optimal patient set-up, and transducer positioning. Results: Of the 105 tumours analyzed, 36, 52, and 17 were low, mid, and high, respectively. The average width of the acoustic window (sciatic notch) for the US beam path was 5.8 ± 1.4cm, average tumour length was 5.24 ± 2.0cm, and average beam path (skin to tumour edge) was 7.3 ± 1.9cm. Eighty one percent of tumours were ≤ 0.3cm from an OAR. Of the 24 virtually simulated tumours to date, 6/8 lower, 6/8 mid, and 1/8 upper rectal tumours were targetable by MR-HIFU. Conclusions: This is the first virtual analysis to evaluate MR-HIFU HT targetability in primary rectal cancer. Results from this study will support MR-HIFU HT as an option to enhance the treatment of primary rectal cancer. Acknowledgments: This study has been funded by the Canadian Cancer Society. Patient & tumour characteristics. [Table: see text]
期刊介绍:
The Journal of Global Oncology (JGO) is an online only, open access journal focused on cancer care, research and care delivery issues unique to countries and settings with limited healthcare resources. JGO aims to provide a home for high-quality literature that fulfills a growing need for content describing the array of challenges health care professionals in resource-constrained settings face. Article types include original reports, review articles, commentaries, correspondence/replies, special articles and editorials.