Kalingga Titon, Nur Ihsan, A. Sakti, Atsushi Higuchi, Hideaki Takenaka, D. Suwardhi, K. Wikantika
{"title":"不同建筑细节层次的屋顶建模中太阳辐射势能的比较","authors":"Kalingga Titon, Nur Ihsan, A. Sakti, Atsushi Higuchi, Hideaki Takenaka, D. Suwardhi, K. Wikantika","doi":"10.5194/isprs-archives-xlviii-m-3-2023-115-2023","DOIUrl":null,"url":null,"abstract":"Abstract. The potential for future energy crises is a problem the world is currently facing. Many countries are switching from fossil to renewable energy to prevent an energy crisis. One of the most developed renewable energy today is solar energy. Easy installation makes solar energy installation not only on a large scale but also on a home scale. Urban areas will be very suitable for building solar photovoltaic (PV) roofs due to minimal open areas. In installing rooftop solar PV, sound planning is needed to predict the energy potential that can be provided by solar energy on the rooftop of a building. Spatial modeling can be done to determine the energy potential and suitable location for rooftop solar PV installation. In building rooftop solar PV modeling, the level of detail of the building will affect the results of the model. The rooftop's shape and the building's height will affect the amount of solar radiation going into the building. However, the higher the level of detail of the building, the higher the cost and processing time will be. This study will review the differences in modeling the potential of rooftop solar PV using different levels of detail. This research will integrate solar radiation data from remote sensing to determine the energy potential of solar radiation and digital surface model data from photogrammetry to create a level of detail for buildings. Integration of solar radiation data and the level of detail of the building will use hillshade analysis. Hillshade analysis can review the shadow effect on the rooftop of a building which will be directly related to the potential of solar energy on the rooftop of the building. This study determines the energy potential on the rooftop of the building with different levels of detail, namely 0, 1, and actual shape, to determine the difference in energy potential in the three scenarios. Hopefully, this research will determine the best level of detail for modeling rooftop solar PV. The best model that can show high accuracy value but at a lower price. Hopefully, this research can also assist policymakers and the public in planning for rooftop solar PV installations to develop renewable energy.\n","PeriodicalId":30634,"journal":{"name":"The International Archives of the Photogrammetry Remote Sensing and Spatial Information Sciences","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"COMPARISON OF POTENTIAL ENERGY OF SOLAR RADIATION IN ROOFTOP MODELING USING DIFFERENT BUILDING LEVELS OF DETAIL\",\"authors\":\"Kalingga Titon, Nur Ihsan, A. Sakti, Atsushi Higuchi, Hideaki Takenaka, D. Suwardhi, K. Wikantika\",\"doi\":\"10.5194/isprs-archives-xlviii-m-3-2023-115-2023\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract. The potential for future energy crises is a problem the world is currently facing. Many countries are switching from fossil to renewable energy to prevent an energy crisis. One of the most developed renewable energy today is solar energy. Easy installation makes solar energy installation not only on a large scale but also on a home scale. Urban areas will be very suitable for building solar photovoltaic (PV) roofs due to minimal open areas. In installing rooftop solar PV, sound planning is needed to predict the energy potential that can be provided by solar energy on the rooftop of a building. Spatial modeling can be done to determine the energy potential and suitable location for rooftop solar PV installation. In building rooftop solar PV modeling, the level of detail of the building will affect the results of the model. The rooftop's shape and the building's height will affect the amount of solar radiation going into the building. However, the higher the level of detail of the building, the higher the cost and processing time will be. This study will review the differences in modeling the potential of rooftop solar PV using different levels of detail. This research will integrate solar radiation data from remote sensing to determine the energy potential of solar radiation and digital surface model data from photogrammetry to create a level of detail for buildings. Integration of solar radiation data and the level of detail of the building will use hillshade analysis. Hillshade analysis can review the shadow effect on the rooftop of a building which will be directly related to the potential of solar energy on the rooftop of the building. This study determines the energy potential on the rooftop of the building with different levels of detail, namely 0, 1, and actual shape, to determine the difference in energy potential in the three scenarios. Hopefully, this research will determine the best level of detail for modeling rooftop solar PV. The best model that can show high accuracy value but at a lower price. Hopefully, this research can also assist policymakers and the public in planning for rooftop solar PV installations to develop renewable energy.\\n\",\"PeriodicalId\":30634,\"journal\":{\"name\":\"The International Archives of the Photogrammetry Remote Sensing and Spatial Information Sciences\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The International Archives of the Photogrammetry Remote Sensing and Spatial Information Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5194/isprs-archives-xlviii-m-3-2023-115-2023\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Social Sciences\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International Archives of the Photogrammetry Remote Sensing and Spatial Information Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5194/isprs-archives-xlviii-m-3-2023-115-2023","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Social Sciences","Score":null,"Total":0}
COMPARISON OF POTENTIAL ENERGY OF SOLAR RADIATION IN ROOFTOP MODELING USING DIFFERENT BUILDING LEVELS OF DETAIL
Abstract. The potential for future energy crises is a problem the world is currently facing. Many countries are switching from fossil to renewable energy to prevent an energy crisis. One of the most developed renewable energy today is solar energy. Easy installation makes solar energy installation not only on a large scale but also on a home scale. Urban areas will be very suitable for building solar photovoltaic (PV) roofs due to minimal open areas. In installing rooftop solar PV, sound planning is needed to predict the energy potential that can be provided by solar energy on the rooftop of a building. Spatial modeling can be done to determine the energy potential and suitable location for rooftop solar PV installation. In building rooftop solar PV modeling, the level of detail of the building will affect the results of the model. The rooftop's shape and the building's height will affect the amount of solar radiation going into the building. However, the higher the level of detail of the building, the higher the cost and processing time will be. This study will review the differences in modeling the potential of rooftop solar PV using different levels of detail. This research will integrate solar radiation data from remote sensing to determine the energy potential of solar radiation and digital surface model data from photogrammetry to create a level of detail for buildings. Integration of solar radiation data and the level of detail of the building will use hillshade analysis. Hillshade analysis can review the shadow effect on the rooftop of a building which will be directly related to the potential of solar energy on the rooftop of the building. This study determines the energy potential on the rooftop of the building with different levels of detail, namely 0, 1, and actual shape, to determine the difference in energy potential in the three scenarios. Hopefully, this research will determine the best level of detail for modeling rooftop solar PV. The best model that can show high accuracy value but at a lower price. Hopefully, this research can also assist policymakers and the public in planning for rooftop solar PV installations to develop renewable energy.