{"title":"远端悬臂延伸对杆固位无腭覆盖义齿连接四种植体周围应力的影响(体外应力分析)","authors":"nesreen El Mekawy, A. Khalifa, Z. Baker, Pham El Quan, Wael Qashout","doi":"10.4172/2332-0702.1000218","DOIUrl":null,"url":null,"abstract":"Aim: This in vitro research was aimed to compare the impact of distal cantilever extension on the stress around four implants retained palateless overdenture by means of a bar. Materials and methods: Four implants were placed bilaterally in lateral incisor and the first premolar positions of edentulous acrylic resin maxillary model; connected bar with 7 mm distal cantilever extension with soft liner female retentive element was used. Eight strain gauges were bonded to the acrylic resin at the mesial and distal surfaces of each implant, stress was measured, then the 7 mm cantilever extension was trimmed and the stress measured for the bar without distal cantilever extension. Results: Bar with distal cantilever extension demonstrate a significant increase in stress compared to the bar without distal cantilever extension in unilateral loading and bilateral loading. During unilateral loading in bar with distal cantilever extension and bar without distal cantilever extension the maximum stress was recorded at mesial side of posterior implant of loading side. Conclusion: The four implants connected with the bar without distal cantilever extension demonstrates lower stress than bar with distal cantilever extension.","PeriodicalId":90904,"journal":{"name":"Journal of oral hygiene & health","volume":"5 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2017-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4172/2332-0702.1000218","citationCount":"1","resultStr":"{\"title\":\"The Impact of Distal Cantilever Extension on the Stress Around FourImplants Connected by a Bar Retained Palateless Overdenture (In VitroStress Analysis)\",\"authors\":\"nesreen El Mekawy, A. Khalifa, Z. Baker, Pham El Quan, Wael Qashout\",\"doi\":\"10.4172/2332-0702.1000218\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Aim: This in vitro research was aimed to compare the impact of distal cantilever extension on the stress around four implants retained palateless overdenture by means of a bar. Materials and methods: Four implants were placed bilaterally in lateral incisor and the first premolar positions of edentulous acrylic resin maxillary model; connected bar with 7 mm distal cantilever extension with soft liner female retentive element was used. Eight strain gauges were bonded to the acrylic resin at the mesial and distal surfaces of each implant, stress was measured, then the 7 mm cantilever extension was trimmed and the stress measured for the bar without distal cantilever extension. Results: Bar with distal cantilever extension demonstrate a significant increase in stress compared to the bar without distal cantilever extension in unilateral loading and bilateral loading. During unilateral loading in bar with distal cantilever extension and bar without distal cantilever extension the maximum stress was recorded at mesial side of posterior implant of loading side. Conclusion: The four implants connected with the bar without distal cantilever extension demonstrates lower stress than bar with distal cantilever extension.\",\"PeriodicalId\":90904,\"journal\":{\"name\":\"Journal of oral hygiene & health\",\"volume\":\"5 1\",\"pages\":\"1-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.4172/2332-0702.1000218\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of oral hygiene & health\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4172/2332-0702.1000218\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of oral hygiene & health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2332-0702.1000218","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

目的:本体外研究旨在比较远端悬臂延伸对四种种植体保留无腭覆盖义齿周围应力的影响。材料和方法:在无牙丙烯酸树脂上颌模型的侧切牙和第一前磨牙位置,双侧放置4个种植体;使用具有7mm远端悬臂延伸部的连接杆,该连接杆具有软衬垫阴性保持元件。在每个植入物的近中表面和远端表面,将八个应变仪连接到丙烯酸树脂上,测量应力,然后修剪7mm的悬臂延伸,并测量没有远端悬臂延伸的杆的应力。结果:在单侧和双侧加载中,与没有远端悬臂延伸的钢筋相比,远端悬臂延伸钢筋的应力显著增加。在有远端悬臂延伸和没有远端悬臂延伸的杆中进行单侧加载时,最大应力记录在加载侧后植入物的近中侧。结论:四个植入体与无远端悬臂延伸的杆连接,其应力低于有远端悬臂延伸杆连接。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Impact of Distal Cantilever Extension on the Stress Around FourImplants Connected by a Bar Retained Palateless Overdenture (In VitroStress Analysis)
Aim: This in vitro research was aimed to compare the impact of distal cantilever extension on the stress around four implants retained palateless overdenture by means of a bar. Materials and methods: Four implants were placed bilaterally in lateral incisor and the first premolar positions of edentulous acrylic resin maxillary model; connected bar with 7 mm distal cantilever extension with soft liner female retentive element was used. Eight strain gauges were bonded to the acrylic resin at the mesial and distal surfaces of each implant, stress was measured, then the 7 mm cantilever extension was trimmed and the stress measured for the bar without distal cantilever extension. Results: Bar with distal cantilever extension demonstrate a significant increase in stress compared to the bar without distal cantilever extension in unilateral loading and bilateral loading. During unilateral loading in bar with distal cantilever extension and bar without distal cantilever extension the maximum stress was recorded at mesial side of posterior implant of loading side. Conclusion: The four implants connected with the bar without distal cantilever extension demonstrates lower stress than bar with distal cantilever extension.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信