基于超声的体积计算机辅助显示心脏在定量评估胎儿主动脉和肺动脉直径中的价值

Q4 Medicine
L. Dai, Bowen Zhao, Y. Yu, M. Pan, Bei Wang, Xiaohui Peng, Ran Chen
{"title":"基于超声的体积计算机辅助显示心脏在定量评估胎儿主动脉和肺动脉直径中的价值","authors":"L. Dai, Bowen Zhao, Y. Yu, M. Pan, Bei Wang, Xiaohui Peng, Ran Chen","doi":"10.3760/CMA.J.ISSN.1004-4477.2020.01.006","DOIUrl":null,"url":null,"abstract":"Objective \nTo explore the feasibility of Sonography based Volume Computer Aided Display Heart (SonoVCADheart) in the display of the fetal ventricular outflow views, and compare diameters of fetal aorta (AO) and pulmonary artery (PA) measured by two-dimensional echocardiography (2DE) and SonoVCADheart. \n \n \nMethods \nEighty singleton fetuses in the second and third trimesters of pregnancy in January 2019 in Sir Run Run Shaw Hospital, Zhejiang University College of Medicine were enrolled. Conventional 2DE examinations were performed. The volume datasets were analyzed offline using the new automatic image processing software SonoVCADheart. The diameters of AO and PA were measured by 2DE and SonoVCADheart, respectively. Pearson correlation analysis was used to evaluate the correlation between the two methods. The consistency of the two methods was verified by Bland-Altman analysis, and he reliability of SonoVCADheart was assessed using the intraclass correlation coefficient (ICC). \n \n \nResults \nFetal ventricular outflow views were successfully obtained using SonoVCADheart in 73(91.2%) of 80 fetuses. There were good correlations between the two methods for measuring the diameters of AO and PA (r=0.953, 0.971; all P<0.001). The 95% agreement limits of AO and PA were (-0.669, 0.568)mm and (-0.632, 0.580)mm, respectively. ICC demonstrated that SonoVCADheart achieved great repeatability both between and within observers. \n \n \nConclusions \nSonoVCADheart may have potentials for the quantitative evaluation of fetal ventricular outflow tracts with its good repeatability and reliability. \n \n \nKey words: \nEchocardiography; Sonography based Volume Computer Aided Display Heart; Aorta diameters; Pulmonary artery diameters","PeriodicalId":10224,"journal":{"name":"中华超声影像学杂志","volume":"29 1","pages":"31-36"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Value of sonography based volume computer aided display heart in quantitative evaluation of fetal aortic and pulmonary artery diameters\",\"authors\":\"L. Dai, Bowen Zhao, Y. Yu, M. Pan, Bei Wang, Xiaohui Peng, Ran Chen\",\"doi\":\"10.3760/CMA.J.ISSN.1004-4477.2020.01.006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective \\nTo explore the feasibility of Sonography based Volume Computer Aided Display Heart (SonoVCADheart) in the display of the fetal ventricular outflow views, and compare diameters of fetal aorta (AO) and pulmonary artery (PA) measured by two-dimensional echocardiography (2DE) and SonoVCADheart. \\n \\n \\nMethods \\nEighty singleton fetuses in the second and third trimesters of pregnancy in January 2019 in Sir Run Run Shaw Hospital, Zhejiang University College of Medicine were enrolled. Conventional 2DE examinations were performed. The volume datasets were analyzed offline using the new automatic image processing software SonoVCADheart. The diameters of AO and PA were measured by 2DE and SonoVCADheart, respectively. Pearson correlation analysis was used to evaluate the correlation between the two methods. The consistency of the two methods was verified by Bland-Altman analysis, and he reliability of SonoVCADheart was assessed using the intraclass correlation coefficient (ICC). \\n \\n \\nResults \\nFetal ventricular outflow views were successfully obtained using SonoVCADheart in 73(91.2%) of 80 fetuses. There were good correlations between the two methods for measuring the diameters of AO and PA (r=0.953, 0.971; all P<0.001). The 95% agreement limits of AO and PA were (-0.669, 0.568)mm and (-0.632, 0.580)mm, respectively. ICC demonstrated that SonoVCADheart achieved great repeatability both between and within observers. \\n \\n \\nConclusions \\nSonoVCADheart may have potentials for the quantitative evaluation of fetal ventricular outflow tracts with its good repeatability and reliability. \\n \\n \\nKey words: \\nEchocardiography; Sonography based Volume Computer Aided Display Heart; Aorta diameters; Pulmonary artery diameters\",\"PeriodicalId\":10224,\"journal\":{\"name\":\"中华超声影像学杂志\",\"volume\":\"29 1\",\"pages\":\"31-36\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中华超声影像学杂志\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3760/CMA.J.ISSN.1004-4477.2020.01.006\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华超声影像学杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/CMA.J.ISSN.1004-4477.2020.01.006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的探讨超声容积计算机辅助显示心脏(SonoVCADheart)显示胎儿心室流出面图像的可行性,并比较二维超声心动图(2DE)和SonoVCADheart测量的胎儿主动脉(AO)和肺动脉(PA)直径。方法选取2019年1月浙江大学医学院邵逸夫医院中晚期妊娠单胎胎儿80例。进行常规2DE检查。使用新的自动图像处理软件SonoVCADheart对体积数据集进行离线分析。分别用2DE和SonoVCADheart测量AO和PA的直径。采用Pearson相关分析评价两种方法的相关性。采用Bland-Altman分析验证两种方法的一致性,采用类内相关系数(intraclass correlation coefficient, ICC)评价SonoVCADheart的可靠性。结果80例胎儿中73例(91.2%)使用SonoVCADheart成功获得胎儿心室流出图。两种方法测定AO和PA的直径具有良好的相关性(r=0.953, 0.971;所有P < 0.001)。AO和PA的95%一致性限分别为(-0.669,0.568)mm和(-0.632,0.580)mm。ICC证明了SonoVCADheart在观察者之间和观察者内部都具有很高的可重复性。结论SonoVCADheart具有良好的重复性和可靠性,可用于胎儿心室流出道的定量评价。关键词:超声心动图;基于超声的体积计算机辅助显示心脏主动脉直径;肺动脉直径
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Value of sonography based volume computer aided display heart in quantitative evaluation of fetal aortic and pulmonary artery diameters
Objective To explore the feasibility of Sonography based Volume Computer Aided Display Heart (SonoVCADheart) in the display of the fetal ventricular outflow views, and compare diameters of fetal aorta (AO) and pulmonary artery (PA) measured by two-dimensional echocardiography (2DE) and SonoVCADheart. Methods Eighty singleton fetuses in the second and third trimesters of pregnancy in January 2019 in Sir Run Run Shaw Hospital, Zhejiang University College of Medicine were enrolled. Conventional 2DE examinations were performed. The volume datasets were analyzed offline using the new automatic image processing software SonoVCADheart. The diameters of AO and PA were measured by 2DE and SonoVCADheart, respectively. Pearson correlation analysis was used to evaluate the correlation between the two methods. The consistency of the two methods was verified by Bland-Altman analysis, and he reliability of SonoVCADheart was assessed using the intraclass correlation coefficient (ICC). Results Fetal ventricular outflow views were successfully obtained using SonoVCADheart in 73(91.2%) of 80 fetuses. There were good correlations between the two methods for measuring the diameters of AO and PA (r=0.953, 0.971; all P<0.001). The 95% agreement limits of AO and PA were (-0.669, 0.568)mm and (-0.632, 0.580)mm, respectively. ICC demonstrated that SonoVCADheart achieved great repeatability both between and within observers. Conclusions SonoVCADheart may have potentials for the quantitative evaluation of fetal ventricular outflow tracts with its good repeatability and reliability. Key words: Echocardiography; Sonography based Volume Computer Aided Display Heart; Aorta diameters; Pulmonary artery diameters
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
中华超声影像学杂志
中华超声影像学杂志 Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
0.80
自引率
0.00%
发文量
9126
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信