{"title":"偏心荷载作用下方形连接和非连接桩筏基础的试验研究","authors":"A. S. Azizkandi, R. Taherkhani, A. Taji","doi":"10.22059/CEIJ.2019.261279.1498","DOIUrl":null,"url":null,"abstract":"In the recent years, non-connected piled raft foundation has been considered as an economical and practical deep foundation in the situation that high shear and concentrated loads may occur at the connection of the raft and pile head. This paper was presented an experimental study of a square foundation on the effects of parameters such as S/D, L/D and etc. in two cases of connected or non-connected piled raft system under the eccentrically loaded raft. The results was showed that square raft in the case of S/D = 3 and L/D = 8, the bearing capacity of the non-connected piles is more than that of the connected piles. The results of the experiments was showed pile length is more effective than the pile spacing in connected pile raft system. However by decreasing pile spacing, bearing capacity is increased in non-connected pile raft and pile spacing is more effective than the pile spacing in non-connected pile raft system. Comparison of bearing capacity and settlement indicated in the non-connected piled raft system, the longer piles not only has not much effect in increasing bearing capacity significantly, but also has lower effect on the reduction of the settlement. Also in non-connected piled raft system by increasing the pile spacing reduced BPI (bearing pile index) wile in connected piled raft system increased.","PeriodicalId":43959,"journal":{"name":"Civil Engineering Infrastructures Journal-CEIJ","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Experimental Study of a Square Foundation with Connected and Non-Connected Piled Raft Foundation Under Eccentrically Loaded\",\"authors\":\"A. S. Azizkandi, R. Taherkhani, A. Taji\",\"doi\":\"10.22059/CEIJ.2019.261279.1498\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the recent years, non-connected piled raft foundation has been considered as an economical and practical deep foundation in the situation that high shear and concentrated loads may occur at the connection of the raft and pile head. This paper was presented an experimental study of a square foundation on the effects of parameters such as S/D, L/D and etc. in two cases of connected or non-connected piled raft system under the eccentrically loaded raft. The results was showed that square raft in the case of S/D = 3 and L/D = 8, the bearing capacity of the non-connected piles is more than that of the connected piles. The results of the experiments was showed pile length is more effective than the pile spacing in connected pile raft system. However by decreasing pile spacing, bearing capacity is increased in non-connected pile raft and pile spacing is more effective than the pile spacing in non-connected pile raft system. Comparison of bearing capacity and settlement indicated in the non-connected piled raft system, the longer piles not only has not much effect in increasing bearing capacity significantly, but also has lower effect on the reduction of the settlement. Also in non-connected piled raft system by increasing the pile spacing reduced BPI (bearing pile index) wile in connected piled raft system increased.\",\"PeriodicalId\":43959,\"journal\":{\"name\":\"Civil Engineering Infrastructures Journal-CEIJ\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2019-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Civil Engineering Infrastructures Journal-CEIJ\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22059/CEIJ.2019.261279.1498\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, CIVIL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Civil Engineering Infrastructures Journal-CEIJ","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22059/CEIJ.2019.261279.1498","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 3

摘要

近年来,无连接桩筏基础被认为是一种经济实用的深基础,适用于筏板与桩头连接处可能发生高剪切和集中荷载的情况。本文以方形基础为试验对象,研究了在偏心筏板荷载作用下两种连接或不连接的桩筏体系中S/D、L/D等参数的影响。结果表明:方筏在S/D = 3、L/D = 8时,非连通桩的承载力大于连通桩的承载力;试验结果表明,在连接桩筏系统中,桩长比桩间距更有效。而减小桩间距可以提高非连通桩筏系统的承载力,且桩间距比非连通桩筏系统的桩间距更有效。非连通桩筏体系的承载力与沉降对比表明,较长的桩不仅对显著提高承载力的作用不大,而且对减小沉降的作用也较低。在非连通桩筏体系中,增大桩间距会降低承载桩指数,而在连通桩筏体系中则会提高承载桩指数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Experimental Study of a Square Foundation with Connected and Non-Connected Piled Raft Foundation Under Eccentrically Loaded
In the recent years, non-connected piled raft foundation has been considered as an economical and practical deep foundation in the situation that high shear and concentrated loads may occur at the connection of the raft and pile head. This paper was presented an experimental study of a square foundation on the effects of parameters such as S/D, L/D and etc. in two cases of connected or non-connected piled raft system under the eccentrically loaded raft. The results was showed that square raft in the case of S/D = 3 and L/D = 8, the bearing capacity of the non-connected piles is more than that of the connected piles. The results of the experiments was showed pile length is more effective than the pile spacing in connected pile raft system. However by decreasing pile spacing, bearing capacity is increased in non-connected pile raft and pile spacing is more effective than the pile spacing in non-connected pile raft system. Comparison of bearing capacity and settlement indicated in the non-connected piled raft system, the longer piles not only has not much effect in increasing bearing capacity significantly, but also has lower effect on the reduction of the settlement. Also in non-connected piled raft system by increasing the pile spacing reduced BPI (bearing pile index) wile in connected piled raft system increased.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.30
自引率
60.00%
发文量
0
审稿时长
47 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信