N. Basaglia, N. Mazzini, P. Boldrini, P. Bacciglieri, E. Contenti, G. Ferraresi
{"title":"利用带声信号的测角器生物反馈治疗膝反曲。一年的随访。","authors":"N. Basaglia, N. Mazzini, P. Boldrini, P. Bacciglieri, E. Contenti, G. Ferraresi","doi":"10.2340/165019778921125130","DOIUrl":null,"url":null,"abstract":"The aim was to evaluate the effect of a biofeedback electrogoniometer in the control of recurvation of the knee while walking in patients with neurological diseases. Eighteen patients were trained daily for 12.8 sessions on average with an electrogoniometer attached to the knee, which gave a signal at a threshold value of 180 degrees in order to avoid hypertension of the knee. The improvement was statistically significant even after one year.","PeriodicalId":76523,"journal":{"name":"Scandinavian journal of rehabilitation medicine","volume":"21 3 1","pages":"125-30"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"25","resultStr":"{\"title\":\"Biofeedback treatment of genu-recurvatum using an electrogoniometric device with an acoustic signal. One-year follow-up.\",\"authors\":\"N. Basaglia, N. Mazzini, P. Boldrini, P. Bacciglieri, E. Contenti, G. Ferraresi\",\"doi\":\"10.2340/165019778921125130\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The aim was to evaluate the effect of a biofeedback electrogoniometer in the control of recurvation of the knee while walking in patients with neurological diseases. Eighteen patients were trained daily for 12.8 sessions on average with an electrogoniometer attached to the knee, which gave a signal at a threshold value of 180 degrees in order to avoid hypertension of the knee. The improvement was statistically significant even after one year.\",\"PeriodicalId\":76523,\"journal\":{\"name\":\"Scandinavian journal of rehabilitation medicine\",\"volume\":\"21 3 1\",\"pages\":\"125-30\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-05-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"25\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Scandinavian journal of rehabilitation medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2340/165019778921125130\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scandinavian journal of rehabilitation medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2340/165019778921125130","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Biofeedback treatment of genu-recurvatum using an electrogoniometric device with an acoustic signal. One-year follow-up.
The aim was to evaluate the effect of a biofeedback electrogoniometer in the control of recurvation of the knee while walking in patients with neurological diseases. Eighteen patients were trained daily for 12.8 sessions on average with an electrogoniometer attached to the knee, which gave a signal at a threshold value of 180 degrees in order to avoid hypertension of the knee. The improvement was statistically significant even after one year.