{"title":"装有热管的墙体夏季动态传热分析","authors":"Zhigang Zhang, Guanxiang Xie, T. Cao","doi":"10.1080/17512549.2019.1592706","DOIUrl":null,"url":null,"abstract":"ABSTRACT The wall implanted with heat pipes overcomes the contradiction between building energy efficiency and wall insulation by transferring the radiant heat from the sun to room during heating season and transferring the heat from room to outside during cooling season. This paper establishes the dynamic thermal transfer model of wall implanted with heat pipes (WIHP) in summer and simulates the dynamic heat transfer process. As revealed by the results, WIHP works 6.2 hours per day on average during the cold season. The rise in the average heat transfer from indoor to outdoor was measured to be 16.66 W/m2, and the surface temperature was found to drop by 2°C on average as compared to the conventional wall. In comparison, the new wall exhibited an improved capability in terms of heat dissipation, indicating that it was effective in lowering energy consumption and boosting indoor thermal comfort.","PeriodicalId":46184,"journal":{"name":"Advances in Building Energy Research","volume":"14 1","pages":"403 - 423"},"PeriodicalIF":2.1000,"publicationDate":"2020-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/17512549.2019.1592706","citationCount":"1","resultStr":"{\"title\":\"Dynamic heat transfer analysis of the wall implanted with heat pipes in summer\",\"authors\":\"Zhigang Zhang, Guanxiang Xie, T. Cao\",\"doi\":\"10.1080/17512549.2019.1592706\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT The wall implanted with heat pipes overcomes the contradiction between building energy efficiency and wall insulation by transferring the radiant heat from the sun to room during heating season and transferring the heat from room to outside during cooling season. This paper establishes the dynamic thermal transfer model of wall implanted with heat pipes (WIHP) in summer and simulates the dynamic heat transfer process. As revealed by the results, WIHP works 6.2 hours per day on average during the cold season. The rise in the average heat transfer from indoor to outdoor was measured to be 16.66 W/m2, and the surface temperature was found to drop by 2°C on average as compared to the conventional wall. In comparison, the new wall exhibited an improved capability in terms of heat dissipation, indicating that it was effective in lowering energy consumption and boosting indoor thermal comfort.\",\"PeriodicalId\":46184,\"journal\":{\"name\":\"Advances in Building Energy Research\",\"volume\":\"14 1\",\"pages\":\"403 - 423\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2020-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/17512549.2019.1592706\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in Building Energy Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/17512549.2019.1592706\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Building Energy Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/17512549.2019.1592706","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 1

摘要

摘要:墙体植入热管解决了建筑节能与墙体保温之间的矛盾,在采暖季节将太阳的辐射热传递到室内,在制冷季节将室内的热量传递到室外。本文建立了夏季墙体植入热管的动态传热模型,模拟了墙体植入热管的动态传热过程。结果显示,在寒冷季节,WIHP平均每天工作6.2小时。从室内到室外的平均换热量增加了16.66 W/m2,与传统墙体相比,表面温度平均下降了2℃。相比之下,新墙体在散热方面表现出更好的能力,表明它在降低能耗和提高室内热舒适方面是有效的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dynamic heat transfer analysis of the wall implanted with heat pipes in summer
ABSTRACT The wall implanted with heat pipes overcomes the contradiction between building energy efficiency and wall insulation by transferring the radiant heat from the sun to room during heating season and transferring the heat from room to outside during cooling season. This paper establishes the dynamic thermal transfer model of wall implanted with heat pipes (WIHP) in summer and simulates the dynamic heat transfer process. As revealed by the results, WIHP works 6.2 hours per day on average during the cold season. The rise in the average heat transfer from indoor to outdoor was measured to be 16.66 W/m2, and the surface temperature was found to drop by 2°C on average as compared to the conventional wall. In comparison, the new wall exhibited an improved capability in terms of heat dissipation, indicating that it was effective in lowering energy consumption and boosting indoor thermal comfort.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Advances in Building Energy Research
Advances in Building Energy Research CONSTRUCTION & BUILDING TECHNOLOGY-
CiteScore
4.80
自引率
5.00%
发文量
11
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信