电感耦合等离子体质谱连续在线浸出法研究小麦、Miswak牙刷和Miswak果实中的生物可及铅

IF 3.4 2区 化学 Q1 SPECTROSCOPY
Randa A. Althobiti, D. Beauchemin
{"title":"电感耦合等离子体质谱连续在线浸出法研究小麦、Miswak牙刷和Miswak果实中的生物可及铅","authors":"Randa A. Althobiti, D. Beauchemin","doi":"10.46770/as.2021.708","DOIUrl":null,"url":null,"abstract":"In this study, sources of Pb are investigated using the 206Pb/207Pb isotopic ratio measured by inductively coupled plasma quadrupole mass spectrometry in the bio-accessible fractions from wheat, Miswak toothbrush (also used as chewing stick) and Miswak fruit. These samples were obtained for the in vitro batch and on-line leaching methods that mimic the human gastrointestinal tract by sequentially using artificial saliva, gastric juice and intestinal fluid for extraction. The two methods provided similar results according to a Student’s t-test at the 95% confidence level. Significant (p < 0.05) differences in 206Pb/207Pb were noted at the 95% confidence level in different artificial body fluids. Except for unpolluted Miswak toothbrush and Miswak fruit, which only contained geogenic Pb, the samples contained a mixture of geogenic and anthropogenic Pb, with bio-accessible Pb in saliva being mainly from a geogenic source, whereas bio-accessible Pb in the stomach and intestinal fluids was mainly from anthropogenic sources. Despite the fact that leaded petrol was phased out in Saudi Arabia in 2001, a Miswak toothbrush collected on the side of a busy road after exposure for only a few days and Safeer wheat were still being contaminated with Pb and had an isotopic composition matching that of Pb added to petrol. The 208Pb/206Pb isotopic ratio for gastric bio-accessible Pb also matched that reported in tetraethyllead. The 206Pb/207Pb isotopic ratios of intestinal bio-accessible Pb from Qassim wheat and Safeer wheat point to coal combustion as the source. Overall, these results highlight the need for continued Pb monitoring and the value of examining bio-accessible fractions periodically to identify Pb sources.","PeriodicalId":8642,"journal":{"name":"Atomic Spectroscopy","volume":" ","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2021-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"An Isotopic Study of Bio-accessible Lead in Wheat, Miswak Toothbrush and Miswak Fruit Using the Continuous On-line Leaching Method with Inductively Coupled Plasma Mass Spectrometry\",\"authors\":\"Randa A. Althobiti, D. Beauchemin\",\"doi\":\"10.46770/as.2021.708\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, sources of Pb are investigated using the 206Pb/207Pb isotopic ratio measured by inductively coupled plasma quadrupole mass spectrometry in the bio-accessible fractions from wheat, Miswak toothbrush (also used as chewing stick) and Miswak fruit. These samples were obtained for the in vitro batch and on-line leaching methods that mimic the human gastrointestinal tract by sequentially using artificial saliva, gastric juice and intestinal fluid for extraction. The two methods provided similar results according to a Student’s t-test at the 95% confidence level. Significant (p < 0.05) differences in 206Pb/207Pb were noted at the 95% confidence level in different artificial body fluids. Except for unpolluted Miswak toothbrush and Miswak fruit, which only contained geogenic Pb, the samples contained a mixture of geogenic and anthropogenic Pb, with bio-accessible Pb in saliva being mainly from a geogenic source, whereas bio-accessible Pb in the stomach and intestinal fluids was mainly from anthropogenic sources. Despite the fact that leaded petrol was phased out in Saudi Arabia in 2001, a Miswak toothbrush collected on the side of a busy road after exposure for only a few days and Safeer wheat were still being contaminated with Pb and had an isotopic composition matching that of Pb added to petrol. The 208Pb/206Pb isotopic ratio for gastric bio-accessible Pb also matched that reported in tetraethyllead. The 206Pb/207Pb isotopic ratios of intestinal bio-accessible Pb from Qassim wheat and Safeer wheat point to coal combustion as the source. Overall, these results highlight the need for continued Pb monitoring and the value of examining bio-accessible fractions periodically to identify Pb sources.\",\"PeriodicalId\":8642,\"journal\":{\"name\":\"Atomic Spectroscopy\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2021-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Atomic Spectroscopy\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.46770/as.2021.708\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"SPECTROSCOPY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Atomic Spectroscopy","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.46770/as.2021.708","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"SPECTROSCOPY","Score":null,"Total":0}
引用次数: 4

摘要

在这项研究中,使用电感耦合等离子体四极杆质谱法测量的小麦、Miswak牙刷(也用作咀嚼棒)和Miswak水果的生物可及组分中的206Pb/207Pb同位素比来研究Pb的来源。这些样品是通过模拟人类胃肠道的体外分批和在线浸出方法获得的,依次使用人工唾液、胃液和肠液进行提取。根据95%置信水平下的Student t检验,这两种方法提供了相似的结果。在不同人工体液的95%置信水平下,206Pb/207Pb存在显著差异(p<0.05)。除了未受污染的Miswak牙刷和Miswak水果只含有地质成因的Pb外,这些样本含有地质成因和人为成因的Pb的混合物,唾液中的生物可及Pb主要来自地质来源,而胃液和肠液中的生物可达Pb主要来自人为来源。尽管2001年沙特阿拉伯逐步淘汰了含铅汽油,但在一条繁忙的路边收集的一把Miswak牙刷在暴露几天后仍然被铅污染,更安全的小麦的同位素组成与添加到汽油中的铅相匹配。胃生物可及Pb的208Pb/206Pb同位素比值也与四乙基铅的报告相匹配。Qassim小麦和Safeer小麦肠道生物可及Pb的206Pb/207Pb同位素比值表明,燃煤是其来源。总的来说,这些结果突出了持续监测铅的必要性,以及定期检查生物可及组分以确定铅来源的价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An Isotopic Study of Bio-accessible Lead in Wheat, Miswak Toothbrush and Miswak Fruit Using the Continuous On-line Leaching Method with Inductively Coupled Plasma Mass Spectrometry
In this study, sources of Pb are investigated using the 206Pb/207Pb isotopic ratio measured by inductively coupled plasma quadrupole mass spectrometry in the bio-accessible fractions from wheat, Miswak toothbrush (also used as chewing stick) and Miswak fruit. These samples were obtained for the in vitro batch and on-line leaching methods that mimic the human gastrointestinal tract by sequentially using artificial saliva, gastric juice and intestinal fluid for extraction. The two methods provided similar results according to a Student’s t-test at the 95% confidence level. Significant (p < 0.05) differences in 206Pb/207Pb were noted at the 95% confidence level in different artificial body fluids. Except for unpolluted Miswak toothbrush and Miswak fruit, which only contained geogenic Pb, the samples contained a mixture of geogenic and anthropogenic Pb, with bio-accessible Pb in saliva being mainly from a geogenic source, whereas bio-accessible Pb in the stomach and intestinal fluids was mainly from anthropogenic sources. Despite the fact that leaded petrol was phased out in Saudi Arabia in 2001, a Miswak toothbrush collected on the side of a busy road after exposure for only a few days and Safeer wheat were still being contaminated with Pb and had an isotopic composition matching that of Pb added to petrol. The 208Pb/206Pb isotopic ratio for gastric bio-accessible Pb also matched that reported in tetraethyllead. The 206Pb/207Pb isotopic ratios of intestinal bio-accessible Pb from Qassim wheat and Safeer wheat point to coal combustion as the source. Overall, these results highlight the need for continued Pb monitoring and the value of examining bio-accessible fractions periodically to identify Pb sources.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Atomic Spectroscopy
Atomic Spectroscopy 物理-光谱学
CiteScore
5.30
自引率
14.70%
发文量
42
审稿时长
4.5 months
期刊介绍: The ATOMIC SPECTROSCOPY is a peer-reviewed international journal started in 1962 by Dr. Walter Slavin and now is published by Atomic Spectroscopy Press Limited (ASPL). It is intended for the rapid publication of both original articles and review articles in the fields of AAS, AFS, ICP-OES, ICP-MS, GD-MS, TIMS, SIMS, AMS, LIBS, XRF and related techniques. Manuscripts dealing with (i) instrumentation & fundamentals, (ii) methodology development & applications, and (iii) standard reference materials (SRMs) development can be submitted for publication.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信